{"title":"Hearthstone Stoves","description":"\u003cp\u003eExplore HearthStone stoves and hearth products, known for distinctive design, durable construction, and efficient home heating. Compare wood stoves, gas stoves, fireplace inserts, finishes, heating capacities, and features to find the right HearthStone appliance for your home. Proudly manufactured in Morristown, Vermont.\u003c\/p\u003e","products":[{"product_id":"hearthstone-stoves-heritage-freestanding-wood-stove","title":"Hearthstone Stoves Heritage Freestanding Wood Stove","description":"\u003ch2\u003eSoapstone-Lined Cast Iron with TruHybrid™ Catalytic Combustion and a Side Load Door\u003c\/h2\u003e\n\u003cp\u003eFull cast iron construction with 1¼\" soapstone lining, TruHybrid™ catalytic combustion, a side load door, and a published HeatLife™ of up to 25 hours.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 1.1 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e77.3% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished HeatLife™ of up to 25+ hours and burn time of up to 20+ hours, depending on wood, draft, and operating conditions\u003c\/li\u003e\n\u003cli\u003eFull cast iron construction with 1¼\" soapstone lining for gradual radiant heat\u003c\/li\u003e\n\u003cli\u003eSide load door, ordered in a left-loading or right-loading configuration\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 2,000 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eFour current finishes: Matte Black, Brown Enamel, Black Enamel, and Seafoam Enamel\u003c\/li\u003e\n\u003cli\u003e6\" flue collar with top or rear exit, and approval for mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through a catalyst for tertiary combustion. A bypass handle directs combustion products around the catalyst during startup and reloading, and through the catalyst once the catalyst probe shows the stove is in its active range. The Heritage uses two Applied Ceramics ACI-6M2 catalytic combustors, which require periodic inspection and eventual replacement.\u003c\/p\u003e\n\u003ch4\u003eSoapstone and Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003eThe Heritage is built with full cast iron construction and a 1¼\" soapstone lining. Soapstone absorbs the heat of the fire and releases it gradually, warming objects in the room rather than only the air. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and surface fractures may appear with use without affecting stove function.\u003c\/p\u003e\n\u003ch4\u003eSide-Loading Convenience\u003c\/h4\u003e\n\u003cp\u003eWood is loaded through the side door as well as the front, and the Heritage is ordered as either a left-loading or right-loading stove. The loading side affects hearth pad layout, so it should be selected against the intended installation. The optional Side Door Lock Kit reduces the minimum required hearth pad width.\u003c\/p\u003e\n\u003ch4\u003eCast Iron and Enamel Finishes\u003c\/h4\u003e\n\u003cp\u003eThe Heritage is offered in Matte Black and in Brown, Black, and Seafoam porcelain enamel. Enamel finishes are covered against peeling or fading for one year under the HearthStone limited warranty, and replacement stones and enameled parts are drawn from current stock and may vary from originals in color, grain, or pattern.\u003c\/p\u003e\n\u003ch4\u003eFire Viewing and Everyday Operation\u003c\/h4\u003e\n\u003cp\u003eA large glass window lets the fire be seen from a variety of locations in the room. A single primary air lever below the ash lip regulates the burn rate, the bypass handle controls catalyst engagement, and a catalyst probe shows when the stove is in its active temperature range, typically 800°F to 1300°F. An optional ash pan with a shaker grate allows ash removal without shoveling through the front door.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eHearthStone publishes a heating area of up to a maximum of 2,000 square feet and output of up to 60,000 BTU. Under EPA test conditions with Douglas fir test wood, the Heritage 8024 delivered heat at rates ranging from 12,889 to 29,191 BTU\/hr. HearthStone states in the current owner's manual that the Heritage 8024 should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Loading Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Heritage 8024 is built in both left-loading and right-loading versions, and every finish is available in either loading configuration. Pricing varies by finish rather than by loading side.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003eLoading Configuration\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003eLeft Load\u003c\/td\u003e\n\u003ctd\u003e8024-4110L\u003c\/td\u003e\n\u003ctd\u003e$4,999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003eRight Load\u003c\/td\u003e\n\u003ctd\u003e8024-4110R\u003c\/td\u003e\n\u003ctd\u003e$4,999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003eLeft Load\u003c\/td\u003e\n\u003ctd\u003e8024-4120L\u003c\/td\u003e\n\u003ctd\u003e$5,799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003eRight Load\u003c\/td\u003e\n\u003ctd\u003e8024-4120R\u003c\/td\u003e\n\u003ctd\u003e$5,799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Enamel\u003c\/td\u003e\n\u003ctd\u003eLeft Load\u003c\/td\u003e\n\u003ctd\u003e8024-4150L\u003c\/td\u003e\n\u003ctd\u003e$5,799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Enamel\u003c\/td\u003e\n\u003ctd\u003eRight Load\u003c\/td\u003e\n\u003ctd\u003e8024-4150R\u003c\/td\u003e\n\u003ctd\u003e$5,799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeafoam Enamel\u003c\/td\u003e\n\u003ctd\u003eLeft Load\u003c\/td\u003e\n\u003ctd\u003e8024-4161L\u003c\/td\u003e\n\u003ctd\u003e$5,799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeafoam Enamel\u003c\/td\u003e\n\u003ctd\u003eRight Load\u003c\/td\u003e\n\u003ctd\u003e8024-4161R\u003c\/td\u003e\n\u003ctd\u003e$5,799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish and loading configuration. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2, two required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 2,000 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePublished heat output\u003c\/th\u003e\n\u003ctd\u003eUp to 60,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e12,889 to 29,191 BTU\/hr under specific test conditions using Douglas fir test wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eUp to 20+ hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 25+ hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalyst operating range\u003c\/th\u003e\n\u003ctd\u003eTypically 800°F to 1300°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e2.2 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 21\" (53.3 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide load door\u003c\/th\u003e\n\u003ctd\u003eLeft or right, specified at time of order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAsh pan\u003c\/th\u003e\n\u003ctd\u003eOptional, kit 90-54240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e28⅛\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e21⅝\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e30¼\" (76.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e580 lbs (263 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDoor glass\u003c\/th\u003e\n\u003ctd\u003e5 mm x 287 mm x 457 mm ceramic IR or Neoceram IR, replacement glass kit 90-58215\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 39\" x W 29\" x L 36\" (99 x 73.7 x 91.5 cm), add 4\" (10.2 cm) for pallet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop or rear; rear exit requires the top-to-rear venting conversion described in the owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney, 6\" (152 mm) round flue or 8\" x 8\" (203 x 203 mm) square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, top exit\u003c\/th\u003e\n\u003ctd\u003e16 feet (4.9 m) off the floor, or 13 feet 5¾\" (4.1 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, rear exit\u003c\/th\u003e\n\u003ctd\u003e19 feet (5.8 m) off the floor, or 16 feet 5¾\" (5.0 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum chimney height\u003c\/th\u003e\n\u003ctd\u003e30 feet (9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; drafts above 0.1\" WC require a stovepipe damper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 90-53220, minimum 3\" (76 mm) diameter duct supplied by others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved when installed per 24 CFR Part 3280; outside air kit, floor anchoring, and a listed mobile home chimney and connector kit are required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e77.3% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e1.1 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60, using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA file number\u003c\/th\u003e\n\u003ctd\u003eF18-307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 0.11 g\/min, Category 2 (medium low) 0.25 g\/min, Category 3 (medium high) 0.10 g\/min, Category 4 4.12 g\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to ULC Std. S627-2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Heritage 8024 owner's and installation manual. Reduced clearances require the HearthStone rear heat shield, kit 90-68210, and listed close-clearance connector pipe. Double-wall connector figures shown by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003eSide\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003eRear, parallel installation\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003eCorner installation\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eSide\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eRear, parallel installation\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eCorner installation\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eSide\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eRear, parallel installation\u003c\/td\u003e\n\u003ctd\u003e6\" (15 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eCorner installation\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCorner clearances account for clearance of combustibles to the body of the stove only. Minimum hearth pad dimensions must still be maintained and may result in larger distances to the actual combustible surfaces. Canadian installations require additional clearance for several of these measurements; refer to the current manual for the Canadian figures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation, unprotected surfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e60½\" (154 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove side clearance\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove rear clearance\u003c\/td\u003e\n\u003ctd\u003e20\" (51 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eAlcove ceiling above stove top\u003c\/td\u003e\n\u003ctd\u003e33¾\" (86 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eAlcove ceiling above floor\u003c\/td\u003e\n\u003ctd\u003e64\" (163 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material. The Heritage 8024 does not require an insulated hearth pad and there is no R-value requirement; the requirement is ember protection. The dimensions below are measured from the body of the stove, not the legs, and extend beyond the stove as shown.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Floor Protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll installations\u003c\/td\u003e\n\u003ctd\u003eSide load door side\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm) United States \/ 18\" (46 cm) Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll installations\u003c\/td\u003e\n\u003ctd\u003eOpposite side\u003c\/td\u003e\n\u003ctd\u003e5\" (13 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll installations\u003c\/td\u003e\n\u003ctd\u003eRear\u003c\/td\u003e\n\u003ctd\u003e2\" (5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll installations\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm) United States \/ 18\" (46 cm) Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith Side Door Lock Kit 90-70210 installed\u003c\/td\u003e\n\u003ctd\u003eMinimum hearth pad width\u003c\/td\u003e\n\u003ctd\u003e37\" (94 cm) United States \/ 40½\" (103 cm) Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation notice:\u003c\/strong\u003e Clearances and hearth requirements vary by connector type, shielding, loading-door orientation, and installation configuration. Refer to the current Heritage installation manual and applicable local requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeritage 8024 woodstove with catalytic combustors installed\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eWood door and bypass handles with screws and washers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e90-53220\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield and Heritage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e90-57210\u003c\/td\u003e\n\u003ctd\u003e$599\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield, Heritage, and Castleton. Requires a compatible rear heat shield.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsh Pan\u003c\/td\u003e\n\u003ctd\u003e90-54240\u003c\/td\u003e\n\u003ctd\u003e$599\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield and Heritage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Heat Shield\u003c\/td\u003e\n\u003ctd\u003e90-68210\u003c\/td\u003e\n\u003ctd\u003e$129\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield and Heritage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Door Lock Kit\u003c\/td\u003e\n\u003ctd\u003e90-70210\u003c\/td\u003e\n\u003ctd\u003e$89\u003c\/td\u003e\n\u003ctd\u003eFor Heritage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise. An outside air kit is required for mobile home installations.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period. Enamel finish against peeling or fading, glass, the ash grate, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Heritage 8024 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53462624010516,"sku":"8024","price":4999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Heritage8024_blackenamel_200213.webp?v=1785544430"},{"product_id":"hearthstone-stoves-clydesdale-wood-fireplace-insert","title":"Hearthstone Stoves Clydesdale Wood Fireplace Insert","description":"\u003ch2\u003eCast Iron Wood Fireplace Insert with a Soapstone-Lined Firebox, TruHybrid™ Catalytic Combustion, and an Included Blower and Surround\u003c\/h2\u003e\n\u003cp\u003eFull cast iron construction with a soapstone-lined firebox, TruHybrid™ catalytic combustion, a factory-installed blower, an included cast iron surround, and a published HeatLife™ of up to 24 hours.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 1.16 g\/hr particulate emissions under the 2015 EPA particulate standard and approved for sale after May 15, 2020, tested to EPA Methods 28, 28A, and 5H\u003c\/li\u003e\n\u003cli\u003e79% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished HeatLife™ of up to 24 hours, depending on wood, draft, and operating conditions\u003c\/li\u003e\n\u003cli\u003eFull cast iron construction with a soapstone-lined firebox for gradual radiant heat\u003c\/li\u003e\n\u003cli\u003eGenerous firebox accepts logs up to 22\" (55.9 cm), with 2.4 cubic feet of capacity\u003c\/li\u003e\n\u003cli\u003eShips complete with a factory-installed blower and a cast iron surround kit\u003c\/li\u003e\n\u003cli\u003eHeats up to 2,000 square feet, depending on insulation, floor plan, and fuel quality\u003c\/li\u003e\n\u003cli\u003eTwo current finishes: Matte Black and Brown Enamel\u003c\/li\u003e\n\u003cli\u003eRequires a continuous, listed 6\" stainless steel chimney liner extending the full length of the chimney\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eFireplace Integration\u003c\/h4\u003e\n\u003cp\u003eThe Clydesdale 8492 installs into a masonry fireplace built to NFPA 211 standards, with a sealed block-off plate or plug of noncombustible material at the damper area to seal the chimney from room air. The current owner's manual states the insert should not be installed in a factory-built fireplace. A continuous chimney liner with a minimum diameter of 6\" must extend from the insert to the top of the chimney, conforming to the class 3 requirements of chimney liner standards ULC-S635 or ULC-S640, connected positively to the insert's flue collar. The flue collar can be installed vertically or at 30 degrees to suit the position of the liner within the fireplace.\u003c\/p\u003e\n\u003ch4\u003eIncluded Blower\u003c\/h4\u003e\n\u003cp\u003eThe convection blower is factory installed within the front ash lip and runs only when the insert is hot. A speed control wheel in the bottom center of the ash lip adjusts the blower, and the power cord can be routed to the left or right side of the insert during installation.\u003c\/p\u003e\n\u003ch4\u003eIncluded Surround\u003c\/h4\u003e\n\u003cp\u003eA cast iron surround kit ships on top of the insert, with surround panels, assembly hardware, and a surround mounting bracket. An optional surround extension covers an additional 6 inches of space beyond the standard surround, and optional cast iron surround base caps continue the lines of the ash lip and attach with magnets.\u003c\/p\u003e\n\u003ch4\u003eFirebox and Combustion\u003c\/h4\u003e\n\u003cp\u003eThe firebox is lined with soapstone refractory bricks that absorb the heat of the fire and release it gradually. Above the secondary air tube, HearthStone's Thermo-Ceramic baffle system maintains high temperatures in the secondary combustion area, and two Applied Ceramics ACI-6M2 catalytic combustors provide tertiary combustion. A bypass door directs combustion products around the catalysts during startup and reloading, and a catalyst thermometer indicates the active range; the Clydesdale typically operates in the 800°F to 1300°F range.\u003c\/p\u003e\n\u003ch4\u003eLoading and Fire Viewing\u003c\/h4\u003e\n\u003cp\u003eThe generous firebox depth and width allows loading of wood up to 22 inches long through a 22\" wide by 11.5\" high front door, and the large glass window presents an open view of the fire. The front door is reversible so it can be hinged on either the left or the right side.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Clydesdale 8492 is currently orderable in two finishes, and every unit ships complete with the blower and surround. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8492-0010\u003c\/td\u003e\n\u003ctd\u003e$5,699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8492-0020\u003c\/td\u003e\n\u003ctd\u003e$6,199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the insert in the selected finish, shipped complete with blower and surround. Chimney liner components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8492\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2, two required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to 2,000 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e60,000 BTU per hour of cordwood, based on independent laboratory test results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e14,829 to 32,588 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalyst operating range\u003c\/th\u003e\n\u003ctd\u003eTypically 800°F to 1300°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e2.4 cu ft, or 48 pounds of wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003e22\" (55.88 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFront door size\u003c\/th\u003e\n\u003ctd\u003e22\" wide x 11.5\" high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eIncluded, factory installed with speed control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e31.38\" (80.31 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e24.81\" (63 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e23.12\" (58.72 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActual weight\u003c\/th\u003e\n\u003ctd\u003e550 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCastings finish\u003c\/th\u003e\n\u003ctd\u003ePainted matte or porcelain enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFireplace and Surround Requirements\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum fireplace opening\u003c\/th\u003e\n\u003ctd\u003e32½\" wide x 23¼\" high x 13\" deep; the fireplace may taper to 27\" wide x 21\" high at the back wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurround coverage\u003c\/th\u003e\n\u003ctd\u003e47⅛\" wide x 30⅝\" high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurround extension\u003c\/th\u003e\n\u003ctd\u003eOptional kit 94-5990010, 59\" x 36\", extends coverage into the room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit\u003c\/th\u003e\n\u003ctd\u003eTop exit only; flue collar installable vertically or at 30 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney liner size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter, continuous from insert to the top of the chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiner standard\u003c\/th\u003e\n\u003ctd\u003eListed liner meeting class 3 requirements of ULC-S635 or ULC-S640; listed 6\" stainless steel flexible connector to a listed 6\" stainless steel liner in masonry chimneys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eLined chimney with walls at least 4\" (102 mm) thick; 6\" (15.2 cm) round flue or 8\" x 8\" (20 x 20 cm) square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum chimney height\u003c\/th\u003e\n\u003ctd\u003e13 feet (4 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum chimney height\u003c\/th\u003e\n\u003ctd\u003e30 feet (9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDamper area\u003c\/th\u003e\n\u003ctd\u003eSealed block-off plate or plug of noncombustible material required to seal the chimney from room air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e79% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e1.16 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eTested to EPA Methods 28, 28A, and 5H, 40 CFR Part 60; certified to comply with the U.S. EPA 2015 particulate emissions standard and approved for sale after May 15, 2020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification report\u003c\/th\u003e\n\u003ctd\u003ePFS Report F20-631\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 0.56 g\/hr, Category 2 1.26 g\/hr, Category 3 0.79 g\/hr, Category 4 1.79 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; conforms to ULC Std. S628-93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Clydesdale 8492 owner's and installation manual (revision 3\/14\/24) and the current HearthStone Clydesdale product page. The masonry fireplace must be built to NFPA 211 standards. Minimum fireplace dimensions shown are from the current HearthStone Clydesdale product page; the minimum fireplace dimensions figure in the current owner's manual governs installation and must be verified against the printed manual before installation. The mantel shield, kit 94-79700, is available to achieve shielded mantel clearances.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance or Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll installations\u003c\/td\u003e\n\u003ctd\u003eMinimum fireplace opening\u003c\/td\u003e\n\u003ctd\u003e32½\" wide x 23¼\" high x 13\" deep; may taper to 27\" wide x 21\" high at the back wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible mantel, 8\" deep\u003c\/td\u003e\n\u003ctd\u003eFrom the bottom of the insert to the mantel\u003c\/td\u003e\n\u003ctd\u003e39½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielded mantel with kit 94-79700, 8\" deep\u003c\/td\u003e\n\u003ctd\u003eFrom the bottom of the insert to the mantel\u003c\/td\u003e\n\u003ctd\u003e33⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll installations\u003c\/td\u003e\n\u003ctd\u003eTo side trim, from the side of the insert body\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll installations\u003c\/td\u003e\n\u003ctd\u003eTo side wall, from the side of the insert body\u003c\/td\u003e\n\u003ctd\u003e11\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material such as slate or marble tile. Insulation below the noncombustible material must be R1.5, or the bottom of the insert must be installed a minimum of 7\" above hearth protection with R0 insulation (13.25\" if measured from the bottom of the fuel loading opening). Masonry hearths 7\" or higher require ember protection only.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry\u003c\/th\u003e\n\u003cth\u003eMinimum Hearth Extension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003ctd\u003e38\" x 16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003e47\" x 18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used. Clearances to combustible surfaces may be reduced using an NFPA 211 approved wall protection system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation notice:\u003c\/strong\u003e Clearances and hearth requirements vary by fireplace construction, mantel depth, shielding, and installation configuration. Refer to the current Clydesdale 8492 installation manual and applicable local requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClydesdale 8492 fireplace insert with façade and ash lip with factory-installed blower\u003c\/li\u003e\n\u003cli\u003eFaçade top grill, in place on the insert\u003c\/li\u003e\n\u003cli\u003eTwo catalytic combustors, shipped in the firebox\u003c\/li\u003e\n\u003cli\u003eCast iron surround kit, shipped on top of the insert\u003c\/li\u003e\n\u003cli\u003eRefractory soapstone kit, two boxes\u003c\/li\u003e\n\u003cli\u003eWood handle kit with two handles and two screws\u003c\/li\u003e\n\u003cli\u003eOwner's manual packet\u003c\/li\u003e\n\u003cli\u003eTouch-up paint pouch, enamel finishes only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurround Base Cap Set, Matte\u003c\/td\u003e\n\u003ctd\u003e94-5970610\u003c\/td\u003e\n\u003ctd\u003e$139\u003c\/td\u003e\n\u003ctd\u003eFor the Clydesdale; cast iron caps attach to the surround with magnets.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurround Base Cap Set, Brown\u003c\/td\u003e\n\u003ctd\u003e94-5970620\u003c\/td\u003e\n\u003ctd\u003e$169\u003c\/td\u003e\n\u003ctd\u003eFor the Clydesdale; cast iron caps attach to the surround with magnets.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurround Extension, 59\" x 36\"\u003c\/td\u003e\n\u003ctd\u003e94-5990010\u003c\/td\u003e\n\u003ctd\u003e$399\u003c\/td\u003e\n\u003ctd\u003eExtends surround coverage an additional 6 inches beyond the standard surround.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantle Shield\u003c\/td\u003e\n\u003ctd\u003e94-79700\u003c\/td\u003e\n\u003ctd\u003e$239\u003c\/td\u003e\n\u003ctd\u003eAttaches to the bottom of a combustible mantel to achieve shielded mantel clearances; 48\" wide, can be cut to fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise. The blower and surround are included with the insert.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period. Enamel finish against peeling or fading, glass, the ash grate, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Clydesdale 8492 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53592140841236,"sku":"8492","price":5699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Clydesdale8492_black_201013.webp?v=1785897864"},{"product_id":"hearthstone-stoves-mansfield-freestanding-wood-stove","title":"Hearthstone Stoves Mansfield Freestanding Wood Stove","description":"\u003ch2\u003eHearthStone's Largest Soapstone Stove with TruHybrid™ Catalytic Combustion\u003c\/h2\u003e\n\u003cp\u003eFull cast iron construction with over 230 pounds of soapstone, TruHybrid™ catalytic combustion, a deep 21½\" x 20½\" firebox, and published burn times of up to 30+ hours.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.54 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e77.7% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 30+ hours, depending on wood, draft, and operating conditions\u003c\/li\u003e\n\u003cli\u003eHearthStone's largest soapstone stove, built with over 230 pounds of soapstone and full cast iron construction\u003c\/li\u003e\n\u003cli\u003eDeep 21½\" wide by 20½\" deep firebox accepts logs up to 21\" in length\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 2,500 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eThree current finishes: Matte Black, Brown Enamel, and Seafoam Enamel\u003c\/li\u003e\n\u003cli\u003e6\" flue collar with top or rear exit, and approval for U.S. mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through the catalysts for tertiary combustion. A bypass handle directs combustion products around the catalysts during startup and reloading, and through the catalysts once the catalyst thermometer shows the stove is in its active range. The Mansfield uses Applied Ceramics ACI-6M2 catalytic combustors, three required, which require periodic inspection and eventual replacement. The Mansfield typically operates in the 450°F to 1200°F flue gas range, with the catalysts becoming active around 500°F.\u003c\/p\u003e\n\u003ch4\u003eSoapstone and Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003eThe Mansfield is HearthStone's largest soapstone stove, constructed with over 230 pounds of soapstone and full cast iron. Soapstone absorbs the heat of the fire and releases it gradually, warming objects in the room rather than only the air. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and surface fractures may appear with use without affecting stove function.\u003c\/p\u003e\n\u003ch4\u003eDeep Firebox\u003c\/h4\u003e\n\u003cp\u003eThe 21½\" wide by 20½\" deep firebox provides space for building large fires, and accepts logs up to 21\" in length. HearthStone publishes a firebox capacity of 2.9 cubic feet in the current owner's manual.\u003c\/p\u003e\n\u003ch4\u003eFire Viewing and Everyday Operation\u003c\/h4\u003e\n\u003cp\u003eA large glass window lets the fire be seen from a variety of locations in the room. A single primary air lever below the ash lip regulates the burn rate, the bypass handle controls catalyst engagement, and a catalyst thermometer shows when the stove is in the active temperature range. An optional ash pan with a shaker grate allows ash removal without shoveling through the front door.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eHearthStone publishes a heating area of up to a maximum of 2,500 square feet and a maximum heat output of 80,000 BTU per hour of cordwood. Under EPA test conditions, the Mansfield 8013 delivered heat at rates ranging from 14,043 to 32,200 BTU (output). HearthStone states in the current owner's manual that the Mansfield should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Mansfield 8013 is currently orderable in three finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte (polished stone, black matte cast)\u003c\/td\u003e\n\u003ctd\u003e8013-4110\u003c\/td\u003e\n\u003ctd\u003e$5,049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel (polished stone, brown enamel cast)\u003c\/td\u003e\n\u003ctd\u003e8013-4120\u003c\/td\u003e\n\u003ctd\u003e$5,699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeafoam Enamel (polished stone, seafoam enamel cast)\u003c\/td\u003e\n\u003ctd\u003e8013-4161\u003c\/td\u003e\n\u003ctd\u003e$5,699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2, three required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 2,500 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e80,000 BTU per hour of cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e14,043 to 32,200 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eUp to 30+ hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 20 hours, per the current owner's manual (revision 10\/21\/24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical operating range\u003c\/th\u003e\n\u003ctd\u003e450°F to 1200°F flue gas temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e2.9 cu ft (0.082 cubic meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox size\u003c\/th\u003e\n\u003ctd\u003e21½\" wide x 20½\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 21\" (54 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAsh pan\u003c\/th\u003e\n\u003ctd\u003eOptional, kit 90-54240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e32\" (81 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e24⅛\" (61 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e650 lbs (295 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 40\" x W 29.5\" x L 36\" (102 x 75 x 92 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop or rear; rear exit requires the flue collar and flue plate conversion described in the owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney, 6\" (152 mm) round flue or 8\" x 8\" (203 x 203 mm) square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, top exit\u003c\/th\u003e\n\u003ctd\u003e16 feet (4.9 m) off the floor, or 13 feet 5¾\" from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum chimney height, rear exit\u003c\/th\u003e\n\u003ctd\u003e15 feet minimum; 19 feet (5.8 m) off the floor recommended, or 16 feet 5¾\" from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum chimney height\u003c\/th\u003e\n\u003ctd\u003e30 feet (9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; drafts above 0.1\" WC require a stovepipe damper; rear-exit venting requires adequate minimum draft, verified at installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 90-53220, minimum 3\" (76 mm) diameter duct supplied by others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved in the U.S. when installed per 24 CFR Part 3280; outside air kit, floor anchoring, spark arrester, and a listed mobile home chimney and connector kit are required; not approved for mobile home installation in Canada; not for installation in a sleeping room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e77.7% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e0.54 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60, using 19\" Douglas fir crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification report\u003c\/th\u003e\n\u003ctd\u003ePFS Report F21-673\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 16.03 g\/hr, Category 2 (medium low) 24.7 g\/hr, Category 3 (medium high) 77.75 g\/hr, Category 4 64.51 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to ULC Std. S627-2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Mansfield 8013 owner's and installation manual (revision 10\/21\/24). Reduced rear clearances require the HearthStone rear heat shield, kit 90-68210. Close-clearance connector pipe must be tested to UL standards and listed; double-wall figures shown by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands. Dimensions are measured from the edge of the cast iron of the stove unless otherwise indicated.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle- or double-wall connector pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003eSide, parallel installation\u003c\/td\u003e\n\u003ctd\u003e23\" (59 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle- or double-wall connector pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003eRear, parallel installation\u003c\/td\u003e\n\u003ctd\u003e19\" (48 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle- or double-wall connector pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003eCorner installation — stove body to corner wall\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle- or double-wall connector pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003eCorner installation — chimney connector to corner wall\u003c\/td\u003e\n\u003ctd\u003e26.5\" (68 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle- or double-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eSide, parallel installation\u003c\/td\u003e\n\u003ctd\u003e23\" (59 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle- or double-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eRear, parallel installation\u003c\/td\u003e\n\u003ctd\u003e6\" (16 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle- or double-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eCorner installation — stove body to corner wall\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle- or double-wall connector pipe with rear heat shield 90-68210\u003c\/td\u003e\n\u003ctd\u003eCorner installation — chimney connector to corner wall\u003c\/td\u003e\n\u003ctd\u003e26.5\" (68 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear exit configurations\u003c\/td\u003e\n\u003ctd\u003eRear, parallel installation\u003c\/td\u003e\n\u003ctd\u003e19\" (48 cm) without rear heat shield; 6\" (16 cm) with rear heat shield 90-68210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eChimney connector clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo rear heat shield\u003c\/td\u003e\n\u003ctd\u003eConnector to rear wall\u003c\/td\u003e\n\u003ctd\u003e19\" (48 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo rear heat shield\u003c\/td\u003e\n\u003ctd\u003eConnector to ceiling\u003c\/td\u003e\n\u003ctd\u003e21\" (53 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith rear heat shield 90-68210, or with blower kit shield\u003c\/td\u003e\n\u003ctd\u003eConnector to rear wall\u003c\/td\u003e\n\u003ctd\u003e6\" (16 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith rear heat shield 90-68210, or with blower kit shield\u003c\/td\u003e\n\u003ctd\u003eConnector to ceiling\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation, unprotected surfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e74\" (188 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMaximum alcove depth\u003c\/td\u003e\n\u003ctd\u003e43⅛\" (110 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor\u003c\/td\u003e\n\u003ctd\u003e73.5\" (187 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFireplace and mantel installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace installation, unprotected combustible surfaces\u003c\/td\u003e\n\u003ctd\u003eAbove stove\u003c\/td\u003e\n\u003ctd\u003e36\" (91 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace installation, unprotected combustible surfaces\u003c\/td\u003e\n\u003ctd\u003eSide trim\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel with heat shield 94-79700\u003c\/td\u003e\n\u003ctd\u003eAbove stove\u003c\/td\u003e\n\u003ctd\u003e12\" (31 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material. The Mansfield 8013 does not require an insulated hearth pad and there is no R-value requirement; the requirement is ember protection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry\u003c\/th\u003e\n\u003cth\u003eMinimum Floor Protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003ctd\u003e40\" x 34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003e49½\" x 41\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used. Clearances to combustible surfaces may be reduced using an NFPA 211 approved wall protection system with the additional approval of the regulatory authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation notice:\u003c\/strong\u003e Clearances and hearth requirements vary by connector type, shielding, and installation configuration. Refer to the current Mansfield 8013 installation manual and applicable local requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMansfield Model 8013 woodstove with catalytic combustors installed\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eRemovable bypass handle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e90-53220\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield and Heritage. Required for mobile home installations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e90-57210\u003c\/td\u003e\n\u003ctd\u003e$599\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield, Heritage, and Castleton. Requires the rear heat shield, which provides attachment for the blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsh Pan\u003c\/td\u003e\n\u003ctd\u003e90-54240\u003c\/td\u003e\n\u003ctd\u003e$599\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield and Heritage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Heat Shield\u003c\/td\u003e\n\u003ctd\u003e90-68210\u003c\/td\u003e\n\u003ctd\u003e$129\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield and Heritage. Required for reduced rear clearances and for blower installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period. Enamel finish against peeling or fading, glass, the ash grate, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Mansfield 8013 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53592140874004,"sku":"8013","price":5049.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Mansfield8013_200214.webp?v=1785933061"},{"product_id":"hearthstone-stoves-castleton-freestanding-wood-stove","title":"Hearthstone Stoves Castleton Freestanding Wood Stove","description":"\u003ch2\u003eA Compact Soapstone Wood Stove with TruHybrid™ Catalytic Combustion and Extra Long Burn Times\u003c\/h2\u003e\n\u003cp\u003eSoapstone and cast iron construction, TruHybrid™ catalytic combustion, a square 19\" wide by 17\" deep firebox, and published burn times of up to 20+ hours.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.98 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e77.3% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 20+ hours, depending on wood, draft, and operating conditions\u003c\/li\u003e\n\u003cli\u003eSoapstone and cast iron construction, with cast iron produced at HearthStone's own foundry in Spain\u003c\/li\u003e\n\u003cli\u003eSquare 19\" wide by 17\" deep firebox accepts logs up to 18\" in length\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 1,500 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eThree current finishes: Matte Black, Brown Enamel, and Seafoam Enamel\u003c\/li\u003e\n\u003cli\u003e6\" flue collar with top or rear exit, and approval for U.S. mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through the catalyst for tertiary combustion. HearthStone describes a 4-tube secondary combustion system with a fixed baffle that ensures a clean burn before the catalyst performs the finishing touches. A bypass handle directs combustion products around the catalyst during startup and reloading, and through the catalyst once the catalyst probe shows the stove is in its active range. The Castleton uses Applied Ceramics ACI-6M2 catalytic combustors, which require periodic inspection and eventual replacement. The catalyst becomes active around 500°F, and the Castleton 8031 typically operates in the 800°F to 1300°F range.\u003c\/p\u003e\n\u003ch4\u003eSoapstone and Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003eThe Castleton combines soapstone with cast iron elements produced at HearthStone's own foundry. Soapstone absorbs the heat of the fire and releases it gradually, warming objects in the room rather than only the air. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and small surface fractures may appear with use without affecting stove function.\u003c\/p\u003e\n\u003ch4\u003eConvenient Square Firebox\u003c\/h4\u003e\n\u003cp\u003eThe square shape of the Castleton creates a 19\" wide by 17\" deep firebox suited to loading and arranging firewood. HearthStone publishes a firebox capacity of 1.9 cubic feet in the current owner's manual, and the firebox accepts logs up to 18\" in length.\u003c\/p\u003e\n\u003ch4\u003eFire Viewing and Everyday Operation\u003c\/h4\u003e\n\u003cp\u003eA large glass window lets the fire be seen from a variety of locations in the room. A single primary air control lever below the ash lip regulates the burn rate and does not close completely, the bypass handle controls catalyst engagement, and a catalyst probe shows when the stove is in the active temperature range. Turn the stove to high and stoke a big fire, or turn it all the way down to keep a fire burning overnight.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eHearthStone publishes a heating area of up to a maximum of 1,500 square feet and a maximum heat output of 45,000 BTU per hour of cordwood, based on independent laboratory test results. Under EPA test conditions, the Castleton 8031 delivered heat at rates ranging from 12,501 to 24,540 BTU (output). HearthStone states in the current owner's manual that the Castleton should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Castleton 8031 is currently orderable in three finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8031-4110\u003c\/td\u003e\n\u003ctd\u003e$4,049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8031-4120\u003c\/td\u003e\n\u003ctd\u003e$4,749\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeafoam Enamel\u003c\/td\u003e\n\u003ctd\u003e8031-4161\u003c\/td\u003e\n\u003ctd\u003e$4,749\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 1,500 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e45,000 BTU per hour of cordwood, based on independent laboratory test results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e12,501 to 24,540 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eUp to 20+ hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 24 hours, per the current owner's manual (revision 01\/11\/23)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical operating range\u003c\/th\u003e\n\u003ctd\u003e800°F to 1300°F catalyst temperature; catalyst becomes active around 500°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e1.9 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox size\u003c\/th\u003e\n\u003ctd\u003e19\" wide x 17\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 18\" (45.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAsh pan\u003c\/th\u003e\n\u003ctd\u003eNot offered for this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e27½\" (69.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e25½\" (64.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e21⅞\" (55.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e520 lbs (235 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 39\" x W 29\" x L 36\" (99 x 73.7 x 91.5 cm), add 4\" (10.2 cm) for pallet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop or rear; rear exit requires the top-to-rear venting conversion described in the owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter; single-wall connector must be at least 24 MSG or 25 MSG blued steel stovepipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney; maximum 6\" (152 mm) diameter round flue or 8\" x 8\" (203 x 203 mm) tile for best results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, top exit\u003c\/th\u003e\n\u003ctd\u003e16 feet (4.9 m) off the floor, or 13 feet 10⅛\" (4.3 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, rear exit\u003c\/th\u003e\n\u003ctd\u003e19 feet (5.8 m) off the floor, or 16 feet 10⅛\" (5.2 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum chimney height\u003c\/th\u003e\n\u003ctd\u003e30 feet (9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; drafts above 0.1\" WC require a stovepipe damper, verified at installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 90-53300, minimum 3\" (76 mm) diameter duct supplied by others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved in the U.S. when installed per 24 CFR Part 3280; outside air kit, permanent floor attachment using the supplied shipping clips, and a listed mobile home chimney and connector kit with a stainless spark arrester cap are required; not for installation in a sleeping room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFactory-built fireplaces\u003c\/th\u003e\n\u003ctd\u003eThe Castleton is to be installed as a freestanding room heater and is not to be installed in any factory-built fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e77.3% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e0.98 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60 where applicable, using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification file\u003c\/th\u003e\n\u003ctd\u003ePFS File F17-182\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 0.56 g\/min, Category 2 (medium low) 0.43 g\/min, Category 3 (medium high) 0.59 g\/min, Category 4 0.67 g\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to ULC Std. S627-2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Castleton 8031 owner's and installation manual (revision 01\/11\/23). Reduced rear clearances require the HearthStone rear heat shield, kit 90-68300. Close-clearance connector pipe must be listed; double-wall figures shown by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands. Dimensions are measured from the top casting of the stove unless otherwise indicated.\u003c\/p\u003e\n\u003cp\u003eThe manual's clearance figure (Figure 4) defines the measurements as follows: A is the stove side to the side wall, B is the stove rear to the rear wall, C is the chimney connector to the rear wall, D is the chimney connector to the side wall, E is the stove body to the corner wall, and F is the chimney connector to the corner wall.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Configuration\u003c\/th\u003e\n\u003cth\u003eA — Side Wall\u003c\/th\u003e\n\u003cth\u003eB — Rear Wall\u003c\/th\u003e\n\u003cth\u003eC — Connector to Rear Wall\u003c\/th\u003e\n\u003cth\u003eD — Connector to Side Wall\u003c\/th\u003e\n\u003cth\u003eE — Corner Wall\u003c\/th\u003e\n\u003cth\u003eF — Connector to Corner Wall\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e15\" (39 cm)\u003c\/td\u003e\n\u003ctd\u003e20\" (51 cm)\u003c\/td\u003e\n\u003ctd\u003e29.25\" (75 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (53 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, with rear heat shield 90-68300\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003ctd\u003e29.25\" (75 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (53 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e15\" (39 cm)\u003c\/td\u003e\n\u003ctd\u003e20\" (51 cm)\u003c\/td\u003e\n\u003ctd\u003e29.25\" (75 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (53 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, with rear heat shield 90-68300\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e29.25\" (75 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (53 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove installation, single- or double-wall connector, with or without rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003ctd\u003e29.25\" (75 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (53 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eChimney connector clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manual publishes the following chimney connector clearances for through-the-wall top flue or direct rear exit installations (Figure 5).\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Configuration\u003c\/th\u003e\n\u003cth\u003eStove or Direct-Rear-Exit Area to Rear Wall\u003c\/th\u003e\n\u003cth\u003eVertical Chimney Connector to Rear Wall\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe with rear heat shield 90-68300\u003c\/td\u003e\n\u003ctd\u003e11\" (27.94 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (40.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe without rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17\" (43.2 cm)\u003c\/td\u003e\n\u003ctd\u003e22\" (55.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe with rear heat shield 90-68300\u003c\/td\u003e\n\u003ctd\u003e10\" (25.4 cm)\u003c\/td\u003e\n\u003ctd\u003e15\" (38.1 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe without rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17\" (43.2 cm)\u003c\/td\u003e\n\u003ctd\u003e22\" (55.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eClearance to Ceiling\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, unprotected ceiling\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, protected ceiling\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe\u003c\/td\u003e\n\u003ctd\u003eRefer to the connector manufacturer's specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTrim and mantel clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe values below are from the trim and mantel clearance figure (Figure 6) of the current manual, which shows a trim thickness of 1.25\".\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide trim clearance\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop trim clearance above stove\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel height above floor\u003c\/td\u003e\n\u003ctd\u003e60\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation, unprotected surfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e59\" (149.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMaximum alcove depth\u003c\/td\u003e\n\u003ctd\u003e52\" (132.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003e60\" (152.4 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material. The Castleton 8031 does not require an insulated hearth pad and there is no R-value requirement; the requirement is ember protection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry\u003c\/th\u003e\n\u003cth\u003eMinimum Floor Protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003ctd\u003e37\" x 31½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003e47\" x 41\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used. Clearances to combustible surfaces may be reduced using an NFPA 211 approved wall protection system with the additional approval of the regulatory authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation notice:\u003c\/strong\u003e Clearances and hearth requirements vary by connector type, shielding, and installation configuration. Refer to the current Castleton 8031 installation manual and applicable local requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCastleton Model 8031 woodstove with catalytic combustors installed and secured for shipping\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eWood handles with screws and washers\u003c\/li\u003e\n\u003cli\u003eCanadian Handle Kit 90-71310, supplied where applicable for Canadian installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e90-53300\u003c\/td\u003e\n\u003ctd\u003e$199\u003c\/td\u003e\n\u003ctd\u003eFor the Castleton. Required for mobile home installations. Connects to a minimum 3\" duct supplied by others; ducting is not included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e90-57210\u003c\/td\u003e\n\u003ctd\u003e$599\u003c\/td\u003e\n\u003ctd\u003eFor Mansfield, Heritage, and Castleton. Requires the rear heat shield, which provides attachment for the blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Heatshield\u003c\/td\u003e\n\u003ctd\u003e90-68300\u003c\/td\u003e\n\u003ctd\u003e$149\u003c\/td\u003e\n\u003ctd\u003eFor the Castleton. Required for reduced rear clearances and for blower installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period. Enamel finish against peeling or fading, glass, the ash grate, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Castleton 8031 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53592140906772,"sku":"8031","price":4049.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Castleton8031_Seafoam_230810_1.webp?v=1785982332"},{"product_id":"hearthstone-stoves-lincoln-freestanding-wood-stove","title":"Hearthstone Stoves Lincoln Freestanding Wood Stove","description":"\u003ch2\u003eA Compact Soapstone Log Burner with TruHybrid™ Catalytic Combustion\u003c\/h2\u003e\n\u003cp\u003eFull soapstone and cast iron construction, TruHybrid™ catalytic combustion, and a 1.0 cubic foot firebox in a 14-inch-wide body designed for small spaces.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 1.14 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e78.5% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003eCompact 14\" wide body sized for cabins, accessory dwelling units, and smaller rooms; heats up to a maximum of 575 square feet\u003c\/li\u003e\n\u003cli\u003e1.0 cubic foot firebox that burns full-size cordwood up to 18\" long, with 16\" recommended\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 9½ hours on a low burn\u003c\/li\u003e\n\u003cli\u003eEnameled square cook plate on the stove top with sliding catalyst access beneath\u003c\/li\u003e\n\u003cli\u003eOptional clip-on side and rear heat shields reduce wall clearances to as little as 9\" at the sides and 3½\" at the rear\u003c\/li\u003e\n\u003cli\u003eApproved for mobile home installation with the required outside air kit, and for alcove installation per the published clearances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe Lincoln 8060 uses HearthStone's TruHybrid™ system, which combines primary and secondary combustion with tertiary combustion through a catalytic combustor. The stainless steel catalytic combustor becomes active at approximately 500°F (260°C) and burns smoke and remaining particles that were not fully consumed in the firebox. A bypass rod routes combustion products around the catalyst during startup and reloading, and a catalyst thermometer indicates when the stove is in the active range. HearthStone states that when the catalyst is active and fully functional, there should be little to no visible smoke from the chimney.\u003c\/p\u003e\n\u003ch4\u003eSoapstone and Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003eFull soapstone and cast iron construction absorbs the high heat of the fire and radiates gentle, long-lasting warmth into the room. Soapstone warms the objects in the room rather than just the air, and HearthStone's cast iron parts are produced at the company's own foundry in Spain. The large glass window allows fire viewing from a variety of locations in the room.\u003c\/p\u003e\n\u003ch4\u003eCompact Log-Burner Design\u003c\/h4\u003e\n\u003cp\u003eThe Lincoln was designed as a traditional log burner that is simple to use, easy to maintain, and sized for small living spaces. It burns full-size cordwood but fits in tight spaces, and HearthStone positions it for cabins, accessory dwelling units, and smaller rooms within a home. Optional heat shields clip onto either side and the back of the stove so it can be placed closer to walls and tucked into corners.\u003c\/p\u003e\n\u003ch4\u003eEnameled Cook Plate and Sliding Catalyst System\u003c\/h4\u003e\n\u003cp\u003eThe square plate on the top of the stove is finished with HearthStone's food-grade enamel, which makes it practical for warming things up and easy to clean. The catalyst rides on a sliding sled: the bypass rod slides it into position once the fire is hot, and the slide system helps you remember to engage the catalyst for a clean burn. With the cook plate removed, the catalyst is accessible for inspection, cleaning, and service.\u003c\/p\u003e\n\u003ch4\u003eEveryday Operation\u003c\/h4\u003e\n\u003cp\u003eA wood-handled front door provides loading access, and a single primary air control lever under the ash lip regulates the burn rate from high to low. The manufacturer-set minimum low burn rate must not be altered. The primary air control, bypass rod, and catalyst thermometer are the stove's operating controls, and fireplace gloves are recommended when the stove is hot.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eThe Lincoln delivers up to 23,000 BTU per hour of maple cordwood and heats up to a maximum of 575 square feet. Factors unique to the home, including insulation value, number and efficiency of windows, floor plan, stove placement, and fuel quality, can reduce the square footage the stove will heat. The stove requires a chimney draft between 0.06\" and 0.1\" water column, verified at installation.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Lincoln 8060 is currently orderable in two finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8060-4110\u003c\/td\u003e\n\u003ctd\u003e$2,549\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlue Black\u003c\/td\u003e\n\u003ctd\u003e8060-4159\u003c\/td\u003e\n\u003ctd\u003e$3,049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics FIRECAT stainless steel combustor; replacement part 3050-010 or 3050-020 (two approved alternatives)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalyst activation temperature\u003c\/th\u003e\n\u003ctd\u003eApproximately 500°F (260°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 575 sq ft, depending on home insulation, windows, floor plan, stove placement, fuel quality, and other conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e23,000 BTU per hour of maple cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e14,545 to 20,507 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eUp to 9½ hours on low\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 20 hours, per the current owner's manual (revision 11\/10\/25)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e1.0 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 18\" (45 cm); 16\" (40 cm) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoading\u003c\/th\u003e\n\u003ctd\u003eFront load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDoor glass\u003c\/th\u003e\n\u003ctd\u003eCeramic glass, 9.5\" x 8.7\" (per the current spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e28\" (71.1 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e14\" (35.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e24.5\" (62.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e250 lbs (113.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 40\" x W 29\" x L 36\" (102 x 74 x 92 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter; single-wall connector of 24 MSG or 25 MSG blued steel, or listed double-wall connector (published double-wall clearances are specific to Simpson Dura-Vent DVL and may vary with other brands)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney, 6\" (152 mm) round flue or 8\" x 8\" (203 x 203 mm) square tile; an existing 8\" (203 mm) diameter flue can be used with a reducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended chimney height\u003c\/th\u003e\n\u003ctd\u003eMinimum 16 feet (4.9 m) from the top of the stove; maximum 30 feet (9 m) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; drafts above 0.1\" WC require a stovepipe damper, checked at installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 96-53400 with a minimum 3\" (76 mm) diameter duct supplied by others; adapter 90-53308 is available for 4\" duct; in Canada, outside-air installations require the stove to be attached to the floor and a damper allowing 100% closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved when installed per 24 CFR Part 3280; the outside air kit, permanent floor attachment, a spark arrester, and a listed mobile home chimney and connector kit conforming to UL 103 or CAN\/ULC-S629 are required; not for installation in a sleeping room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlcove installation\u003c\/th\u003e\n\u003ctd\u003eApproved; see the published alcove clearances below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFactory-built fireplace\u003c\/th\u003e\n\u003ctd\u003eDo not install the Lincoln 8060 into a factory-built fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e78.5% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e1.14 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60, using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification report\u003c\/th\u003e\n\u003ctd\u003ePFS Report F22-859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 38.7 g\/hr, Category 2 (medium low) 18.2 g\/hr, Category 3 (medium high) 17.3 g\/hr, Category 4 69.0 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to CAN\/ULC Std. S627:2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Lincoln 8060 owner's and installation manual (revision 11\/10\/25). Reduced side clearances require the HearthStone side heat shield, kit 90-68605, installed on each shielded side; reduced rear clearances require the rear heat shield, kit 90-68601. Heat shields can be installed individually to reduce the required distance to the wall being shielded. Close-clearance connector pipe must be tested to UL standards and listed; double-wall figures published by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands. The manual publishes clearances both for the stove body and for the chimney connector, and the tables below state which one each row measures: stove-body rows are measured from the cast body of the stove to the combustible wall, and chimney-connector rows are measured from the connector pipe to the combustible wall. Both must be satisfied in an installation. As a general rule, keep furniture, drapes, wood, paper, and other combustibles at least 36\" (92 cm) away from the stove.\u003c\/p\u003e\n\u003cp\u003eThe clearances below apply to parallel and corner installations; the manual publishes the same values for single-wall and double-wall connector pipe in these configurations.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eNo Heat Shields\u003c\/th\u003e\n\u003cth\u003eWith Side Heat Shields 90-68605\u003c\/th\u003e\n\u003cth\u003eWith Rear Heat Shield 90-68601\u003c\/th\u003e\n\u003cth\u003eWith Side and Rear Heat Shields\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e22\" (56 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e22\" (56 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e27¼\" (70 cm)\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e27¼\" (70 cm)\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to rear wall\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e3½\" (9 cm)\u003c\/td\u003e\n\u003ctd\u003e3½\" (9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to rear wall\u003c\/td\u003e\n\u003ctd\u003e13½\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e13½\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to corner wall\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e7¼\" (19 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to corner wall\u003c\/td\u003e\n\u003ctd\u003e18½\" (47 cm)\u003c\/td\u003e\n\u003ctd\u003e18½\" (47 cm)\u003c\/td\u003e\n\u003ctd\u003e18½\" (47 cm)\u003c\/td\u003e\n\u003ctd\u003e12\" (31 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eThrough-the-rear-wall flue exit (elbow atop the stove to a rear wall exit)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe values below apply to through-the-rear-wall installations with a single-wall connector, and include both the stove-body and the chimney-connector clearances for each shield configuration. For double-wall connectors, use the chimney-connector clearance table that follows and refer to the connector pipe's certification where the manual directs, rather than the single-wall values.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eNo Heat Shields\u003c\/th\u003e\n\u003cth\u003eWith Side Heat Shields 90-68605\u003c\/th\u003e\n\u003cth\u003eWith Rear Heat Shield 90-68601\u003c\/th\u003e\n\u003cth\u003eWith Side and Rear Heat Shields\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e22\" (56 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e22\" (56 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e27¼\" (70 cm)\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e27¼\" (70 cm)\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to rear wall\u003c\/td\u003e\n\u003ctd\u003eUnited States 11\"; Canada 43 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 11\"; Canada 43 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 5½\"; Canada 43 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 5½\"; Canada 43 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to rear wall\u003c\/td\u003e\n\u003ctd\u003eUnited States 15½\"; Canada 54 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 15½\"; Canada 54 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 11\"; Canada 54 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 11\"; Canada 54 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eChimney-connector clearances for the through-the-wall exit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manual separately publishes the clearance from the rear combustible wall to the vertical chimney connector rising from the flue collar, and the clearance from the rear wall for the through-the-wall exit arrangement with no vertical pipe. Where the table shows check pipe certification, use the clearance established by the double-wall connector manufacturer's listing instead of a single-wall value.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eSingle-Wall Pipe, No Rear Heat Shield\u003c\/th\u003e\n\u003cth\u003eSingle-Wall Pipe, With Rear Heat Shield 90-68601\u003c\/th\u003e\n\u003cth\u003eDouble-Wall Pipe\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear wall to the vertical chimney connector, United States\u003c\/td\u003e\n\u003ctd\u003e15½\" (40 cm)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm) with the rear heat shield; otherwise check pipe certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear wall to the vertical chimney connector, Canada\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003ctd\u003eCheck pipe certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear wall to the through-the-wall exit with no vertical pipe, United States\u003c\/td\u003e\n\u003ctd\u003e12½\" (32 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm) with the rear heat shield; otherwise check pipe certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear wall to the through-the-wall exit with no vertical pipe, Canada\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003ctd\u003eCheck pipe certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSingle-wall connector pipe requires a minimum of 18\" of clearance to the ceiling. For double-wall connector pipe, follow the connector manufacturer's ceiling-clearance specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum unshielded alcove width\u003c\/td\u003e\n\u003ctd\u003e58\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, single-wall connector\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor\u003c\/td\u003e\n\u003ctd\u003e58½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, double-wall connector\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor\u003c\/td\u003e\n\u003ctd\u003e58½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, no heat shields\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, no heat shields\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e27¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, no heat shields\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall, United States\u003c\/td\u003e\n\u003ctd\u003e11\" (Canada: see the owner's manual clearance figure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, no heat shields\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall, United States\u003c\/td\u003e\n\u003ctd\u003e15½\" (Canada: see the owner's manual clearance figure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, with side and rear heat shields\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, with side and rear heat shields\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, with side and rear heat shields\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall, United States\u003c\/td\u003e\n\u003ctd\u003e5½\" (Canada: see the owner's manual clearance figure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, with side and rear heat shields\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall, United States\u003c\/td\u003e\n\u003ctd\u003e11\" (Canada: see the owner's manual clearance figure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTrim and mantel clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace installation — protruding trim up to 6\" (16 cm)\u003c\/td\u003e\n\u003ctd\u003eDistance from the stove\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel with 12\" protrusion, no shield\u003c\/td\u003e\n\u003ctd\u003eHeight from the floor\u003c\/td\u003e\n\u003ctd\u003e58½\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material, such as a continuous layer of tile, brick, slate, or glass. The Lincoln 8060 does not require an insulated hearth pad and there is no R-value requirement; hearth pad coverage is for ember protection. The minimum floor protection for United States installations is 27½\" x 37½\", and the minimum floor protection for installations in Canada is 30\" (762 mm) x 47½\" (1206 mm), with the stove positioned on the pad as shown in the hearth diagram in the owner's manual. Rooms with luxury vinyl plank or luxury vinyl tile flooring require extra consideration, because some of these floorings begin to warp at 110°F; consult the flooring manufacturer, as additional shielding may be necessary.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLincoln Model 8060 woodstove with catalytic combustor installed\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eHardware kit with four feet, leveling and mounting hardware, front door handle, air control handle, and catalyst temperature indicator\u003c\/li\u003e\n\u003cli\u003eFloor refractory stones, shipped loose in the firebox for final assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Heat Shield\u003c\/td\u003e\n\u003ctd\u003e90-68601\u003c\/td\u003e\n\u003ctd\u003e$59\u003c\/td\u003e\n\u003ctd\u003eFor the Lincoln 8060. Clips onto the back of the stove; required for the reduced rear clearances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Heat Shield (Left or Right)\u003c\/td\u003e\n\u003ctd\u003e90-68605\u003c\/td\u003e\n\u003ctd\u003e$89\u003c\/td\u003e\n\u003ctd\u003eFor the Lincoln 8060. A single shield that clips onto the left or right side; one shield is required for each side being shielded for the reduced side clearances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter Kit, 3\"\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eListed for the Lincoln. Required for mobile home installations and recommended for well-sealed newer homes; minimum 3\" duct supplied by others.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Increaser, 3\" to 4\"\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eAdapts the outside air starter kit to a 4\" duct for longer outside air runs; listed by HearthStone as a Lincoln accessory.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components and refractory, vermiculite panels, and baffles carry a 2-year period. Enamel finish against peeling or fading, glass, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustor is covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Refer to the complete warranty in the current Lincoln 8060 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53612858409236,"sku":"8060","price":2549.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Lincoln-8060matteblack240116.webp?v=1786152324"},{"product_id":"hearthstone-stoves-manchester-freestanding-wood-stove","title":"Hearthstone Stoves Manchester Freestanding Wood Stove","description":"\u003ch2\u003eFull Cast Iron Convective Heat with TruHybrid™ Catalytic Combustion and Left-Side Loading\u003c\/h2\u003e\n\u003cp\u003eFull cast iron construction with a soapstone-lined firebox, TruHybrid™ catalytic combustion, a left-side loading door with integral ash pan, and published burn times of up to 30+ hours.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.65 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e78% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 30+ hours and HeatLife™ of up to 30 hours, depending on wood, draft, and operating conditions\u003c\/li\u003e\n\u003cli\u003eBuilt-in convective air channel up the back and across the top of the stove that helps circulate warm air through the home\u003c\/li\u003e\n\u003cli\u003eLeft-side loading door accepts logs up to 24\" in length; integral ash pan with shaker grate keeps the hearth tidy\u003c\/li\u003e\n\u003cli\u003eSoapstone-lined 2.45 cubic foot firebox stores heat and releases it gradually\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 2,400 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eCast iron rear heat shield included from the factory\u003c\/li\u003e\n\u003cli\u003eTwo current finishes: Black Matte and Brown Enamel\u003c\/li\u003e\n\u003cli\u003e6\" flue collar with top or rear exit, and approval for U.S. mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through the catalysts for tertiary combustion. A bypass handle directs combustion products around the catalysts during startup and reloading, and through the catalysts once the catalyst thermometer shows the stove is in its active range. The Manchester uses Applied Ceramics ACI-6M2 catalytic combustors, two required per the current illustrated parts list, which require periodic inspection and eventual replacement. The catalysts become active around 500°F, and the Manchester 8362 typically operates in the 800°F to 1300°F range.\u003c\/p\u003e\n\u003ch4\u003eNatural Convective Heat\u003c\/h4\u003e\n\u003cp\u003eThe Manchester is built with an air channel up the back and across the top of the stove, which helps circulate warm air through the home without a fan. An optional blower, kit 93-57600, is available for installations that call for forced air movement.\u003c\/p\u003e\n\u003ch4\u003eCast Iron and Soapstone Construction\u003c\/h4\u003e\n\u003cp\u003eThe Manchester combines full cast iron construction with a soapstone-lined firebox. The soapstone absorbs the heat of the fire and releases it gradually, supporting the stove's long published HeatLife™. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and surface fractures may appear with use without affecting stove function.\u003c\/p\u003e\n\u003ch4\u003eSide Loading and Everyday Convenience\u003c\/h4\u003e\n\u003cp\u003eA left-side loading door accepts logs up to 24\" in length, and the built-in ash pan with a shaker grate allows ash to be sifted from the firebox and carried away without shoveling through the front door. A single primary air lever below the ash lip regulates the burn rate, the bypass handle controls catalyst engagement, and a catalyst thermometer shows when the stove is in the active temperature range. HearthStone requires 18\" between the loading-door side of the stove and the side wall unless the optional side door locking kit is installed, and recommends allowing space for loading through the side door.\u003c\/p\u003e\n\u003ch4\u003eFire Viewing\u003c\/h4\u003e\n\u003cp\u003eA large glass window lets the fire be seen from a variety of locations in the room. An air-wash system helps keep the ceramic glass clear when logs are kept away from the glass and the stove is run at adequate temperatures.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eHearthStone publishes a heating area of up to a maximum of 2,400 square feet and a maximum heat output of 75,000 BTU per hour of cordwood. Under specific EPA test conditions, the Manchester 8362 delivered heat at rates ranging from 14,000 to 33,000 BTU (output). HearthStone states in the current owner's manual that the Manchester should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Manchester 8362 is currently orderable in two finishes. Both current configurations load through a left-side door. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003eLoading Configuration\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eIncluded Equipment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003eLeft load\u003c\/td\u003e\n\u003ctd\u003e8362-0010L\u003c\/td\u003e\n\u003ctd\u003e$5,449\u003c\/td\u003e\n\u003ctd\u003eCast iron rear heat shield included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003eLeft load\u003c\/td\u003e\n\u003ctd\u003e8362-0020L\u003c\/td\u003e\n\u003ctd\u003e$6,149\u003c\/td\u003e\n\u003ctd\u003eCast iron rear heat shield included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8362\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2, two required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 2,400 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e75,000 BTU per hour of cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e14,000 to 33,000 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eUp to 30+ hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 30 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical operating range\u003c\/th\u003e\n\u003ctd\u003e800°F to 1300°F catalyst temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e2.45 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 24\" (61 cm) through the side door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoading\u003c\/th\u003e\n\u003ctd\u003eFront door and left-side loading door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAsh pan\u003c\/th\u003e\n\u003ctd\u003eBuilt in, with ash door and shaker grate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e32⅛\" (81.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e30¼\" (76.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e20\" (50.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e520 lbs (236 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 49.5\" x W 32.4\" x L 24.5\" (126 x 82.3 x 62.2 cm); add 4\" (10.2 cm) for pallet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop or rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney, 6\" (152 mm) round flue or 8\" x 8\" (203 x 203 mm) square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, top exit\u003c\/th\u003e\n\u003ctd\u003e16 feet (4.9 m) off the floor, or 13 feet 5⅛\" (4.1 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, rear exit\u003c\/th\u003e\n\u003ctd\u003e19 feet (5.8 m) off the floor, or 16 feet 5⅛\" (5.0 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum chimney height\u003c\/th\u003e\n\u003ctd\u003e30 feet (9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; drafts above 0.1\" WC require a stovepipe damper, checked at installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 93-53500, minimum 3\" (76 mm) diameter duct supplied by others; adaptor 90-53308 available for 4\" duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved in the U.S. when installed per 24 CFR Part 3280; outside air kit, floor anchoring, a spark arrester, and a listed mobile home chimney and connector kit are required; not for installation in a sleeping room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace installation\u003c\/th\u003e\n\u003ctd\u003eNot to be installed in any factory-built fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e78% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e0.65 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60 where applicable, using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification file\u003c\/th\u003e\n\u003ctd\u003ePFS File F19-023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 40.46 g\/hr, Category 2 (medium low) 37.04 g\/hr, Category 3 (medium high) 63.46 g\/hr, Category 4 79.04 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to ULC Std. S627-2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Manchester 8362 owner's and installation manual (revision 1\/9\/23) and are measured from the body of the stove unless otherwise indicated. The cast iron rear heat shield is included from the factory, and the published clearances apply to the stove as shipped. Reduced clearances require the optional close clearance heat shield, kit 93-68600, which is sold separately. Double-wall connector figures shown by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands; check the specifications from the manufacturer of your connector.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (dimension A)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (dimension B)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (dimension C)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (dimension D)\u003c\/td\u003e\n\u003ctd\u003e33⅝\" (86 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to corner wall (dimension E)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (dimension A)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (dimension B)\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (dimension C)\u003c\/td\u003e\n\u003ctd\u003e15\" (39 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (dimension D)\u003c\/td\u003e\n\u003ctd\u003e33⅝\" (86 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to corner wall (dimension E)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (dimension A)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (dimension B)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (dimension C)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (dimension D)\u003c\/td\u003e\n\u003ctd\u003e31⅝\" (81 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to corner wall (dimension E)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (dimension A)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (dimension B)\u003c\/td\u003e\n\u003ctd\u003e6\" (16 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (dimension C)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (dimension D)\u003c\/td\u003e\n\u003ctd\u003e31⅝\" (81 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to corner wall (dimension E)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSide loading door:\u003c\/strong\u003e The side of the stove with the loading door must be 18\" from the side wall unless the side door locking kit, 93-70607, is installed. HearthStone advises considering space for loading the stove through the side door.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChimney connector clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Type and Configuration\u003c\/th\u003e\n\u003cth\u003eVertical Pipe Length Before Elbow\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003e18\" or more\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe without heat shield\u003c\/td\u003e\n\u003ctd\u003e18\" or more\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eLess than 18\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe without heat shield\u003c\/td\u003e\n\u003ctd\u003eLess than 18\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, direct rear exit\u003c\/td\u003e\n\u003ctd\u003eDirect rear exit\u003c\/td\u003e\n\u003ctd\u003e14\" without heat shield; heat shield configuration listed as N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003e18\" or more\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe without heat shield\u003c\/td\u003e\n\u003ctd\u003e18\" or more\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eLess than 18\"\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe without heat shield\u003c\/td\u003e\n\u003ctd\u003eLess than 18\"\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, direct rear exit\u003c\/td\u003e\n\u003ctd\u003eDirect rear exit\u003c\/td\u003e\n\u003ctd\u003e6\" without heat shield; heat shield configuration listed as N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConnector clearance to ceiling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-wall connector to an unprotected ceiling:\u003c\/strong\u003e 18\" minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-wall connector to a protected ceiling:\u003c\/strong\u003e 9\" minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble-wall connector to the ceiling:\u003c\/strong\u003e follow the connector manufacturer's specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe close clearance heat shield referenced in the connector tables is kit 93-68600.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e62¼\" (159 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMaximum alcove depth\u003c\/td\u003e\n\u003ctd\u003e52\" (132 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, single-wall connector\u003c\/td\u003e\n\u003ctd\u003e68\" (173 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, double-wall connector\u003c\/td\u003e\n\u003ctd\u003e61½\" (163 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, protected surfaces\u003c\/td\u003e\n\u003ctd\u003eAll alcove dimensions\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTrim and mantel clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide trim clearance\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop trim clearance above the stove\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel clearance above the stove\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrim thickness shown in the manual\u003c\/td\u003e\n\u003ctd\u003e1¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual states that the same clearances apply with the stove installed in a fireplace.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material. The Manchester 8362 does not require an insulated hearth pad and there is no R-value requirement; the requirement is ember protection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFloor Protection Measurement\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eApplies To\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum overall floor protection\u003c\/td\u003e\n\u003ctd\u003e48\" x 36¾\"\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum overall floor protection\u003c\/td\u003e\n\u003ctd\u003e56\" x 44\"\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear extension from the stove body\u003c\/td\u003e\n\u003ctd\u003e2\" (6 cm)\u003c\/td\u003e\n\u003ctd\u003eUnited States and Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension from the loading-door opening\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension from the loading-door opening\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEdge of the fuel-door opening to the edge of the hearth\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to the side edge of the hearth\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used. Clearances to combustible surfaces may be reduced using an NFPA 211 approved wall protection system with the additional approval of the regulatory authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation notice:\u003c\/strong\u003e Clearances and hearth requirements vary by connector type, shielding, and installation configuration. Refer to the current Manchester 8362 installation manual and applicable local requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManchester Model 8362 woodstove with catalytic combustors installed\u003c\/li\u003e\n\u003cli\u003eCast iron rear heat shield, included per the current dealer listing\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eBag of handles and hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e93-53500\u003c\/td\u003e\n\u003ctd\u003e$129\u003c\/td\u003e\n\u003ctd\u003eFor Manchester. Required for mobile home installations; connects to a minimum 3\" duct supplied by others.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e93-57600\u003c\/td\u003e\n\u003ctd\u003e$699\u003c\/td\u003e\n\u003ctd\u003eFor Manchester. Optional convection blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtra Close Clearance (Exit) Heat Shield\u003c\/td\u003e\n\u003ctd\u003e93-68600\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eFor Manchester. Required for the reduced clearances shown in the clearance tables. Separate from the included cast iron rear heat shield.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Door Lock Kit\u003c\/td\u003e\n\u003ctd\u003e93-70607\u003c\/td\u003e\n\u003ctd\u003e$99\u003c\/td\u003e\n\u003ctd\u003eFor Manchester. Permits the loading-door side of the stove to be closer than 18\" to the side wall.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eFor use when adapting the Manchester's 3\" outside-air connection to 4\" duct.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period, as do refractory and vermiculite panels and baffles. Enamel finish against peeling or fading, glass, the ash grate, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Manchester 8362 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53616113975572,"sku":"8362","price":5449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/manchester8362_brown_CMYK.webp?v=1786235846"},{"product_id":"hearthstone-stoves-shelburne-freestanding-wood-stove","title":"Hearthstone Stoves Shelburne Freestanding Wood Stove","description":"\u003ch2\u003eDetailed Cast Iron and Soapstone Warmth with TruHybrid™ Catalytic Combustion\u003c\/h2\u003e\n\u003cp\u003eFully detailed cast iron from HearthStone's Spanish foundry, a soapstone-lined 2.0 cubic foot firebox, TruHybrid™ catalytic combustion, and heat for up to 2,000 square feet.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.6 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e79% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 24+ hours, with a HeatLife™ of up to 30 hours per the current owner's manual, depending on wood, draft, and operating conditions\u003c\/li\u003e\n\u003cli\u003eFinely detailed cast iron construction, finished and enameled on all sides so the stove can be placed in the center of a room\u003c\/li\u003e\n\u003cli\u003eSoapstone-lined 2.0 cubic foot firebox accepts logs up to 18\" in length\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 2,000 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eThree current finishes: Black Matte, Brown Enamel, and Basil Enamel\u003c\/li\u003e\n\u003cli\u003e6\" flue collar with top or rear exit, a factory-supplied rear heat shield, and approval for U.S. mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe Shelburne 8372 uses HearthStone's TruHybrid™ system, which combines primary and secondary combustion with tertiary combustion through a catalyst. Two Applied Ceramics FIRECAT steel catalytic combustors (model ACI-6M2) burn smoke and remaining particles that were not fully consumed in the firebox. The combustors become active at approximately 500°F, and the stove typically operates in the 800°F to 1300°F catalyst range. When the catalysts are in the active range and fully functional, there should be little to no visible smoke from the chimney.\u003c\/p\u003e\n\u003ch4\u003eCast Iron Detail, Finished From Every Angle\u003c\/h4\u003e\n\u003cp\u003eThe Shelburne is constructed of high-quality cast iron parts produced at HearthStone's own foundry in Spain and finished in porcelain enamel or traditional black stove paint. It is designed to be seen from all sides: the backside is fully detailed and enameled, so the stove looks equally at home against a wall or in the center of a room. HearthStone's porcelain Majolica enamels are a glass-based finish applied in layers and fired at nearly 2000°F; color variation and fine crazing over time are normal characteristics of this finish.\u003c\/p\u003e\n\u003ch4\u003eSoapstone-Lined Firebox\u003c\/h4\u003e\n\u003cp\u003eThe firebox is lined with soapstone blocks. Soapstone is a natural material that absorbs the high heat of the fire and then radiates a gentle, even warmth into the room, warming the objects in your home rather than just the air. Like all soapstone-lined stoves, the Shelburne must be broken in gradually with a series of small fires to season the stone and cure the furnace cement.\u003c\/p\u003e\n\u003ch4\u003eEveryday Controls\u003c\/h4\u003e\n\u003cp\u003eA single primary air control lever under the ash lip regulates the burn rate, and the control does not close completely, preserving the manufacturer-set minimum burn rate. A bypass handle routes combustion products around the catalysts during startup and reloading, and a supplied catalyst thermometer indicates when the stove is in the active catalyst range. The large glass window uses an air-wash system to help keep the ceramic glass clear during normal operation.\u003c\/p\u003e\n\u003ch4\u003eTop or Rear Venting\u003c\/h4\u003e\n\u003cp\u003eThe Shelburne ships in the vertical (top) flue configuration and can be converted to a direct rear exit by switching the positions of the flue collar and flue plate. Rear exit installations require a draft of at least 0.08\" water column and a minimum chimney height of 15 feet; do not install the stove in the rear exit configuration without sufficient draft.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eIndependent laboratory testing rates the Shelburne 8372 at a maximum heat output of 60,000 BTUs per hour burning cordwood, with an EPA-tested delivered output range of 12,600 to 33,600 BTUs per hour under specific test conditions. It is rated to heat up to a maximum of 2,000 square feet; home insulation, window efficiency, floor plan, stove placement, and fuel quality can reduce the area the stove will heat.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Shelburne 8372 is currently orderable in three finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8372-0010\u003c\/td\u003e\n\u003ctd\u003e$3,949\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8372-0020\u003c\/td\u003e\n\u003ctd\u003e$4,749\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasil Enamel\u003c\/td\u003e\n\u003ctd\u003e8372-0083\u003c\/td\u003e\n\u003ctd\u003e$4,749\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum heat output: 60,000 BTUs per hour of cordwood, based on independent laboratory test results\u003c\/li\u003e\n\u003cli\u003eEPA-tested delivered heat output range: 12,600 to 33,600 BTUs per hour (output) under specific test conditions\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 2,000 square feet, depending on home insulation, windows, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eBurn time: up to 24+ hours; HeatLife™: up to 30 hours, as published in the current owner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFirebox capacity: 2.0 cubic feet, lined with soapstone blocks\u003c\/li\u003e\n\u003cli\u003eMaximum log length: up to 18\" (45.7 cm)\u003c\/li\u003e\n\u003cli\u003eFuel: natural cordwood only; seasoned, air-dried firewood at or near 20% moisture content is recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 31½\" (80.0 cm)\u003c\/li\u003e\n\u003cli\u003eWidth: 26\" (66.0 cm)\u003c\/li\u003e\n\u003cli\u003eDepth: 21¼\" (54.0 cm)\u003c\/li\u003e\n\u003cli\u003eWeight: 430 lbs (195 kg)\u003c\/li\u003e\n\u003cli\u003eCrate dimensions: 40\" H x 29\" W x 36\" L\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFlue exit: top or rear; the stove ships in the vertical configuration and is convertible to rear exit\u003c\/li\u003e\n\u003cli\u003eChimney connector: 6\" (152 mm) diameter, 24 MSG or 25 MSG blued steel single-wall pipe, or listed double-wall connector pipe\u003c\/li\u003e\n\u003cli\u003eMetal chimney: 6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/li\u003e\n\u003cli\u003eMasonry chimney: code-approved and lined; 6\" (152 mm) round flue or up to 8\" x 8\" (203 x 203 mm) tile for best results; an existing 8\" diameter flue may be used with a reducer\u003c\/li\u003e\n\u003cli\u003eRequired draft: between 0.06\" and 0.1\" water column; install a stovepipe damper for drafts above 0.1\" water column\u003c\/li\u003e\n\u003cli\u003eRear exit installations: minimum draft 0.08\" water column and minimum chimney height of 15 feet\u003c\/li\u003e\n\u003cli\u003eRecommended minimum chimney height: 16 feet off the floor for top exit, 19 feet off the floor for rear exit; recommended maximum chimney height 30 feet\u003c\/li\u003e\n\u003cli\u003eOutside air: optional Outside Air Starter kit 96-53400 connects the air intake to a minimum 3\" outside duct; required for mobile home installations\u003c\/li\u003e\n\u003cli\u003eMobile home approved when installed per 24 CFR Part 3280 with the outside air kit, permanent floor attachment, and a listed mobile home chimney kit with spark arrester; do not install in a sleeping room\u003c\/li\u003e\n\u003cli\u003eAlcove installation approved with the clearances and minimum alcove dimensions published in the owner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeighted-average efficiency: 79% HHV, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.6 g\/hr particulate emissions under the 2020 EPA standard, tested with crib wood per EPA Method 28R\u003c\/li\u003e\n\u003cli\u003eCO emission rates by burn category: 9.0 g\/hr (low), 21.0 g\/hr (medium low), 33.0 g\/hr (medium high), and 51.6 g\/hr (category 4)\u003c\/li\u003e\n\u003cli\u003eConforms to UL Std. 1482-2022 and certified to ULC Std. S627-2021 (Report F20-632)\u003c\/li\u003e\n\u003cli\u003eCatalysts: two Applied Ceramics FIRECAT steel combustors, model ACI-6M2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Shelburne 8372 owner's and installation manual (revision 1\/11\/23), including the complete Figure 4 clearance table. The Shelburne includes a factory-supplied rear heat shield; the reduced-clearance heat shield referenced below is the shield supplied with Blower \u0026amp; Reduced Clearance Heatshield Combo kit 96-57400. Single-wall connector clearances are generic; the double-wall connector clearances shown by HearthStone are specific to Simpson DuraVent DVL and may vary with other brands.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eParallel and corner installation clearances to combustibles\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eStove Body to Side Wall\u003c\/th\u003e\n\u003cth\u003eStove Body to Rear Wall\u003c\/th\u003e\n\u003cth\u003eChimney Connector to Rear Wall\u003c\/th\u003e\n\u003cth\u003eChimney Connector to Side Wall\u003c\/th\u003e\n\u003cth\u003eStove Body to Corner Wall\u003c\/th\u003e\n\u003cth\u003eChimney Connector to Corner Wall\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e17.5\" (45 cm)\u003c\/td\u003e\n\u003ctd\u003e21\" (53 cm)\u003c\/td\u003e\n\u003ctd\u003e26\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no heat shield, rear exit through wall\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e17.5\" (45 cm)\u003c\/td\u003e\n\u003ctd\u003e21\" (53 cm)\u003c\/td\u003e\n\u003ctd\u003e26\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003e26\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e18.5\" (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, blower kit heat shield (96-57400)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003e26\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e18.5\" (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003e26\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e18.5\" (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, blower kit heat shield (96-57400)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e5\" (13 cm)\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003ctd\u003e26\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e18.5\" (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe reduced 5\" rear clearance is published only for double-wall connector pipe used with the heat shield supplied in blower kit 96-57400. With single-wall connector pipe, the blower kit heat shield carries the same published clearances as the included rear heat shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChimney connector clearances, through-the-wall top flue exit (manual Figure 5)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following clearances apply to the through-the-wall top flue exit arrangement. The manual states that these clearances apply to all sides of the connection pipe; for stove side clearances, refer to the parallel installation table above.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pipe and Heat Shield Configuration\u003c\/th\u003e\n\u003cth\u003eStove Rear Reference to Rear Combustible Wall\u003c\/th\u003e\n\u003cth\u003eVertical Chimney Connector to Rear Combustible Wall\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e16.5\" (42 cm)\u003c\/td\u003e\n\u003ctd\u003e21\" (53 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, blower kit heat shield (96-57400)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, blower kit heat shield (96-57400)\u003c\/td\u003e\n\u003ctd\u003e5\" (13 cm)\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConnector-to-ceiling clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCeiling Clearance\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector to unprotected ceiling\u003c\/td\u003e\n\u003ctd\u003e18\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector to protected ceiling\u003c\/td\u003e\n\u003ctd\u003e9\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector to ceiling\u003c\/td\u003e\n\u003ctd\u003eFollow the connector manufacturer's specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTrim and mantel clearances (manual Figure 6)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese trim and mantel clearances also apply when the stove is installed in a fireplace; however, the Shelburne 8372 is not approved for installation in any factory-built fireplace. For ceiling clearance, refer to the applicable connector-to-ceiling requirements above.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTrim and Mantel Measurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide trim clearance\u003c\/td\u003e\n\u003ctd\u003e5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel height above the floor\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel depth\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrim thickness shown in Figure 6\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation, unprotected surfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAlcove Measurement (all four alcove configurations in Figure 4)\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to rear wall\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to rear wall\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e26\" (66 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to corner wall\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to corner wall\u003c\/td\u003e\n\u003ctd\u003e18.5\" (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e52\" (132.1 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, single-wall connector\u003c\/td\u003e\n\u003ctd\u003e61.5\" (156.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, double-wall connector\u003c\/td\u003e\n\u003ctd\u003e61.5\" (156.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe reduced 5\" rear clearance is not published for alcove installations; the manual lists an 11\" stove body to rear wall clearance for all alcove configurations. For protected surfaces, refer to NFPA 211. Clearances to combustibles may be reduced only with an NFPA-approved wall protection system and the additional approval of the regulatory authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a continuous layer of noncombustible material such as tile, brick, slate, or glass. The Shelburne 8372 requires ember protection only; no insulated hearth pad or R-value is required.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFloor Protection Measurement\u003c\/th\u003e\n\u003cth\u003eUnited States\u003c\/th\u003e\n\u003cth\u003eCanada\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum overall floor protection\u003c\/td\u003e\n\u003ctd\u003e33¼\" x 33½\"\u003c\/td\u003e\n\u003ctd\u003e42\" x 43½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear extension beyond the stove\u003c\/td\u003e\n\u003ctd\u003e2\" (6 cm)\u003c\/td\u003e\n\u003ctd\u003e2\" (6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront extension from the edge of the fuel-door opening\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide extension\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm), measured from the edge of the fuel-door opening\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm), measured from the stove body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eInstallations over Luxury Vinyl Plank or Luxury Vinyl Tile flooring require extra consideration; some LVP and LVT products begin to warp at 110°F, so consult the flooring manufacturer and provide additional shielding if necessary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShelburne Model 8372 woodstove with two catalytic combustors installed\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eFactory-supplied simple rear heat shield\u003c\/li\u003e\n\u003cli\u003eCatalyst thermometer\u003c\/li\u003e\n\u003cli\u003eShipping clips, used to attach the stove to the floor in mobile home installations and in Canadian outside-air installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower \u0026amp; Reduced Clearance Heatshield Combo\u003c\/td\u003e\n\u003ctd\u003e96-57400\u003c\/td\u003e\n\u003ctd\u003e$649\u003c\/td\u003e\n\u003ctd\u003eConvection blower with reduced-clearance rear heat shield. The blower circulates heated air with an automatic snap switch and adjustable rheostat. The kit's heat shield attaches to the back of the stove; its reduced 5\" rear clearance is published for double-wall connector pipe, while single-wall installations carry the same clearances as the included rear heat shield.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eConnects the stove's air intake to a minimum 3\" outside air duct (ducting supplied by others; a 4\" duct adapter, kit 90-53308, is available). Required for all mobile home installations and recommended for well-sealed homes. In Canada, the stove must be attached to the floor when this kit is used.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eFor use when adapting the Shelburne's 3\" outside-air connection to 4\" duct.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period. Enamel finish against peeling or fading, glass, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Shelburne 8372 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53616183247124,"sku":"8372","price":3949.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Shelburne8372_201001.webp?v=1786240156"},{"product_id":"hearthstone-stoves-craftsbury-freestanding-wood-stove","title":"Hearthstone Stoves Craftsbury Freestanding Wood Stove","description":"\u003ch2\u003eCompact Cast Iron Heat with TruHybrid™ Catalytic Combustion and a Soapstone-Lined Firebox\u003c\/h2\u003e\n\u003cp\u003eSoapstone-lined cast iron construction from HearthStone's Spanish foundry, TruHybrid™ catalytic combustion, burn times of up to 16+ hours, and a compact footprint sized for a large room or small home.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 1.07 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e79% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 16+ hours, with a HeatLife™ of up to 20 hours per the current owner's manual\u003c\/li\u003e\n\u003cli\u003eHigh-quality cast iron parts from HearthStone's own foundry in Spain, finished in matte paint or porcelain enamel, with a soapstone-lined firebox\u003c\/li\u003e\n\u003cli\u003e1.32 cubic foot firebox accepts logs up to 16\" in length\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 1,400 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eThree current finishes: Black Matte, Brown Enamel, and Basil Enamel\u003c\/li\u003e\n\u003cli\u003e6\" flue collar, shipped in the top-exit configuration and convertible to direct rear exit per the owner's manual, with approval for U.S. mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through the catalysts for tertiary combustion. A bypass handle directs combustion products around the catalysts during startup and reloading, and through the catalysts once the catalyst thermometer shows the stove is in its active range. The Craftsbury uses Applied Ceramics ACI-6M2 catalytic combustors, installed as two cartridges, which require periodic inspection and eventual replacement. The catalysts become active around 500°F, and the Craftsbury typically operates in the 800°F to 1300°F catalyst temperature range. HearthStone states that a roaring fire produces no visible smoke from the chimney when the TruHybrid™ system is engaged and functioning.\u003c\/p\u003e\n\u003ch4\u003eCast Iron and Soapstone Construction\u003c\/h4\u003e\n\u003cp\u003eThe Craftsbury is constructed of high-quality cast iron parts produced at HearthStone's own foundry in Spain and is lined with soapstone blocks. Soapstone absorbs the heat of the fire and releases it gradually, warming objects in the room rather than only the air. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and surface fractures may appear with use without affecting stove function. The enamel finishes are porcelain Majolica enamels, applied as molten glass fused to the iron; HearthStone notes that color variation and fine crazing lines are a normal, cosmetic part of this finish.\u003c\/p\u003e\n\u003ch4\u003eCompact Firebox\u003c\/h4\u003e\n\u003cp\u003eThe 1.32 cubic foot firebox accepts logs up to 16\" in length. HearthStone notes that the amount and weight of wood contained per cubic foot of firebox volume can vary from 10 to 25 pounds per cubic foot depending on the type of wood, moisture content, packing density, and other factors.\u003c\/p\u003e\n\u003ch4\u003eFire Viewing and Everyday Operation\u003c\/h4\u003e\n\u003cp\u003eA large glass window lets the fire be seen from a variety of locations in the room. A single primary air control lever below the ash lip regulates the burn rate, the bypass handle controls catalyst engagement, and a catalyst thermometer shows when the stove is in the active temperature range. The front door glass is a ceramic, thermal shock-resistant glass made specifically for use in woodstoves.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eHearthStone publishes a heating area of up to a maximum of 1,400 square feet and a maximum heat output of 40,000 BTU per hour of cordwood, based on independent laboratory test results. Under specific EPA test conditions, the Craftsbury 8392 has been shown to deliver heat at rates ranging from 13,900 to 31,600 BTU (output). HearthStone states in the current owner's manual that the Craftsbury should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Craftsbury 8392 is currently orderable in three finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8392-0010\u003c\/td\u003e\n\u003ctd\u003e$3,599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8392-0020\u003c\/td\u003e\n\u003ctd\u003e$4,299\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasil Enamel\u003c\/td\u003e\n\u003ctd\u003e8392-0083\u003c\/td\u003e\n\u003ctd\u003e$4,299\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2, two cartridges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 1,400 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e40,000 BTU per hour of cordwood, based on independent laboratory test results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e13,900 to 31,600 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eUp to 16+ hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 20 hours, per the current owner's manual (revision 1\/6\/2023)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical catalyst operating range\u003c\/th\u003e\n\u003ctd\u003e800°F to 1300°F, with catalyst activation around 500°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e1.32 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 16\" (40.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e30½\" (77.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e23¾\" (59.1 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e19⅜\" (49.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e350 lbs (159 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 40\" x W 29\" x L 36\" (102 x 74 x 92 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop or rear; shipped in the top (vertical) configuration, convertible to direct rear exit per the owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney, 6\" (152 mm) round flue or 8\" x 8\" (203 x 203 mm) square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, top exit\u003c\/th\u003e\n\u003ctd\u003e16 feet (4.9 m) off the floor, or 13 feet 7¼\" (4.3 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum chimney height, rear exit\u003c\/th\u003e\n\u003ctd\u003e15 feet minimum; 19 feet (5.8 m) off the floor recommended, or 16 feet 7¼\" (5.2 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum chimney height\u003c\/th\u003e\n\u003ctd\u003e30 feet (9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e-0.06\" to -0.1\" water column; drafts beyond -0.1\" WC require a stovepipe damper; direct rear exit requires a minimum draft of -0.08\" WC, checked at installation time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 96-53400, minimum 3\" (76 mm) diameter duct supplied by others; optional adapter 90-53308 for 4\" duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved for U.S. manufactured home installation per 24 CFR Part 3280; an outside air kit, permanent floor attachment, a listed mobile home chimney and connector kit per UL 103 or ULC S629, and a spark arrester are required; not for installation in a sleeping room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFactory-built fireplaces\u003c\/th\u003e\n\u003ctd\u003eThe Craftsbury is a freestanding room heater and is not to be installed in any factory-built fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eRear-Flue Conversion\u003c\/h4\u003e\n\u003cp\u003eThe Craftsbury ships in the vertical, top-flue configuration and may be installed with a direct rear flue. Converting to the rear-exit configuration requires switching the positions of the flue collar and the flue plate and modifying the included rear heat shield by removing a section so the pipe can pass through it, following the steps in the owner's manual. In the rear-exit configuration a draft of -0.08\" WC or more is necessary to ensure proper function of the stove, and the minimum chimney height is 15 feet; HearthStone recommends a minimum chimney height of 19 feet off the floor for rear-exit connections. Do not install the stove in the rear-exit configuration if the installation does not have sufficient draft.\u003c\/p\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e79% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e1.07 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60 where applicable, using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification report\u003c\/th\u003e\n\u003ctd\u003ePFS Report F17-183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 40.7 g\/hr, Category 2 (medium low) 16.3 g\/hr, Category 3 (medium high) 8.6 g\/hr, Category 4 60.1 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to ULC Std. S627-2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Craftsbury 8392 owner's and installation manual (revision 1\/6\/2023). Dimensions are measured from the furthest point on the cast body of the stove unless otherwise indicated. The Craftsbury ships with a rear heat shield included; the optional blower kit 96-57400 supplies its own reduced-clearance heat shield, and the manual's clearance tables list these two shield configurations separately. Double-wall connector figures shown by HearthStone are specific to Simpson DuraVent DVL and may vary with other brands; check the specifications from the manufacturer of your connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eParallel and corner installation clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eStove body to side wall (A)\u003c\/th\u003e\n\u003cth\u003eStove body to rear wall (B)\u003c\/th\u003e\n\u003cth\u003eChimney connector to rear wall (C)\u003c\/th\u003e\n\u003cth\u003eChimney connector to side wall (D)\u003c\/th\u003e\n\u003cth\u003eStove body to corner wall (E)\u003c\/th\u003e\n\u003cth\u003eChimney connector to corner wall (F)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003ctd\u003e25⅞\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003ctd\u003e25½\" (65 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e18¾\" (48 cm)\u003c\/td\u003e\n\u003ctd\u003e25⅞\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e17¼\" (44 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e18¾\" (48 cm)\u003c\/td\u003e\n\u003ctd\u003e25⅞\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e17¼\" (44 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003ctd\u003e9¾\" (25 cm)\u003c\/td\u003e\n\u003ctd\u003e14¾\" (38 cm)\u003c\/td\u003e\n\u003ctd\u003e25⅞\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e17¼\" (44 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003ctd\u003e9¾\" (25 cm)\u003c\/td\u003e\n\u003ctd\u003e14¾\" (38 cm)\u003c\/td\u003e\n\u003ctd\u003e25⅞\" (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e17¼\" (44 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAlcove Installation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, included rear heat shield, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (A)\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, included rear heat shield, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (B)\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, included rear heat shield, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (C)\u003c\/td\u003e\n\u003ctd\u003e18¾\" (48 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, included rear heat shield, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (D)\u003c\/td\u003e\n\u003ctd\u003e25⅞\" (66 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, included rear heat shield, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eCorner measurements (E, F)\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, blower kit shield 96-57400, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (A)\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, blower kit shield 96-57400, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (B)\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, blower kit shield 96-57400, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (C)\u003c\/td\u003e\n\u003ctd\u003e18¾\" (48 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, blower kit shield 96-57400, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (D)\u003c\/td\u003e\n\u003ctd\u003e25⅞\" (66 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, blower kit shield 96-57400, single- or double-wall connector\u003c\/td\u003e\n\u003ctd\u003eCorner measurements (E, F)\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e51¾\" (132 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, single-wall connector\u003c\/td\u003e\n\u003ctd\u003e56\" (142.3 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, double-wall connector\u003c\/td\u003e\n\u003ctd\u003e56\" (142.3 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove\u003c\/td\u003e\n\u003ctd\u003eProtected surfaces\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eClearances to combustible surfaces may be reduced using an NFPA 211 approved wall protection system with the additional approval of the regulatory authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChimney connector clearances, through-the-wall or rear-exit arrangement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor a top-flue installation venting through the wall, or a direct rear-flue installation, the manual publishes the following clearances from the stove and the vertical chimney connector to the rear combustible wall. These clearances pertain to all sides of the connection pipe. For stove side clearances, use the parallel installation clearances above.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector and Shield Configuration\u003c\/th\u003e\n\u003cth\u003eStove body or rear shield to rear combustible wall (A)\u003c\/th\u003e\n\u003cth\u003eVertical chimney connector to rear combustible wall (B)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e15½\" (40 cm)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e18¾\" (48 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e18¾\" (48 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e9¾\" (25 cm)\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e9¾\" (25 cm)\u003c\/td\u003e\n\u003ctd\u003e14\" (36 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConnector ceiling clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eCeiling Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector to unprotected ceiling\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector to protected ceiling\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector to ceiling\u003c\/td\u003e\n\u003ctd\u003eFollow the connector manufacturer's specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTrim and mantel clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTrim or Mantel Measurement\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide trim clearance\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel height above floor\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel depth\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrim thickness shown\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeiling clearance\u003c\/td\u003e\n\u003ctd\u003eRefer to the applicable connector and ceiling clearance requirements above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese trim and mantel clearances also apply when the stove is positioned in an applicable fireplace opening; however, the Craftsbury 8392 is not approved for installation in any factory-built fireplace.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material, such as a continuous layer of tile, brick, slate, or glass. The Craftsbury 8392 does not require an insulated hearth pad and there is no R-value requirement; the requirement is ember protection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry\u003c\/th\u003e\n\u003cth\u003eMinimum Floor Protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003ctd\u003e31½\" wide x 33\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003e40\" wide x 43\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth Extension\u003c\/th\u003e\n\u003cth\u003eUnited States\u003c\/th\u003e\n\u003cth\u003eCanada\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront extension, measured from the edge of the fuel-door opening\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide extension\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm), measured from the edge of the fuel-door opening\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm), measured from the body of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear extension, measured from the stove body to the rear edge of the hearth\u003c\/td\u003e\n\u003ctd\u003e2\" (6 cm)\u003c\/td\u003e\n\u003ctd\u003e2\" (6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation notice:\u003c\/strong\u003e Clearances and hearth requirements vary by connector type, shielding, and installation configuration. Refer to the current Craftsbury 8392 owner's and installation manual and applicable local requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCraftsbury Model 8392 woodstove with catalytic combustors installed\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eRear heat shield (part 5640-024), listed as included in the manual's replacement parts information\u003c\/li\u003e\n\u003cli\u003eShipping clips, used for permanent floor attachment where required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower \u0026amp; Reduced Clearance Heatshield Combo\u003c\/td\u003e\n\u003ctd\u003e96-57400\u003c\/td\u003e\n\u003ctd\u003e$649\u003c\/td\u003e\n\u003ctd\u003eConvection blower with its own reduced-clearance heat shield, which screws to the back of the stove and channels the air from the blower. The manual's clearance tables list the blower kit shield configuration separately from the included rear heat shield.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eConnects the stove's air intake to a minimum 3\" diameter duct supplied by others. Required for mobile home installations. In Canada, the stove must be attached to the home's floor and a duct damper allowing 100% closure must be installed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eOptional adapter for a 4\" outside-air duct, used with outside air kit 96-53400.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone and to cast iron not listed elsewhere. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period. Enamel finish against peeling or fading, glass, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Craftsbury 8392 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53616226304276,"sku":"8392","price":3599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Craftsbury8392_room-brown_201013_01.webp?v=1786241580"},{"product_id":"hearthstone-stoves-green-mountain-80-freestanding-wood-stove","title":"Hearthstone Stoves Green Mountain 80 Freestanding Wood Stove","description":"\u003ch2\u003eCast Iron TruHybrid™ Wood Stove with a Soapstone-Lined Firebox and a 6-Inch Top- or Rear-Exit Flue\u003c\/h2\u003e\n\u003cp\u003eEuropean cast iron construction with a soapstone-lined 3.15 cubic foot firebox, TruHybrid™ catalytic combustion, a versatile 6-inch flue, and a published HeatLife™ of up to 30 hours.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.53 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e80% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished HeatLife™ of up to 30 hours\u003c\/li\u003e\n\u003cli\u003e3.15 cubic foot soapstone-lined firebox accepts logs up to 23\" in length\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 2,500 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003e6\" flue collar with top or rear exit\u003c\/li\u003e\n\u003cli\u003eNew-generation Green Mountain styling with an elegant silhouette, linear cast iron texture, and a flush door supported by hidden hinges\u003c\/li\u003e\n\u003cli\u003eLarge glass window designed to show as much of the fire as possible\u003c\/li\u003e\n\u003cli\u003eApproved for U.S. mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003cli\u003eCurrent finish: Black Matte\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through the catalysts for tertiary combustion. A bypass handle directs combustion products around the catalysts during startup and reloading, and through the catalysts once the catalyst thermometer shows the stove is in its active range. The Green Mountain 80 Model 8681 uses Applied Ceramics ACI-6M2 catalytic combustors, three required, which require periodic inspection and eventual replacement. The catalysts become active around 500°F, and the stove typically operates in the 800°F to 1300°F catalyst temperature range. HearthStone notes that there should be little to no visible smoke from the chimney when the catalysts are in the active zone and fully functional.\u003c\/p\u003e\n\u003ch4\u003eCast Iron and Soapstone-Lined Firebox\u003c\/h4\u003e\n\u003cp\u003eThe Green Mountain 80 is built from European cast iron produced at HearthStone's own foundry in Spain, with a soapstone-lined firebox. Soapstone absorbs the heat of the fire and releases it gradually, warming objects in the room rather than only the air. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and small surface fractures may appear with use without affecting stove function.\u003c\/p\u003e\n\u003ch4\u003eNew-Generation Green Mountain Styling\u003c\/h4\u003e\n\u003cp\u003eThe Model 8681 carries the new generation of Green Mountain styling, defined by an elegant silhouette, linear cast iron texture, and a flush door supported by hidden hinges. The window into the stove is designed to let you see as much fire as possible from a variety of locations in the room.\u003c\/p\u003e\n\u003ch4\u003e6-Inch Flue with Top or Rear Exit\u003c\/h4\u003e\n\u003cp\u003eThe Model 8681 features a 6\" flue collar and can be vented through the top or the rear of the stove. To support the firebox, HearthStone focused on the ease of airflow through the stove, supporting quick starting and efficient burning. Minimum chimney height differs by exit: a top-exit installation requires a minimum chimney height of 16 feet off the floor, or 13 feet 5 inches from the top of the stove, while a rear-exit installation requires a minimum of 19 feet off the floor, or 16 feet 5 inches from the top of the stove. The stove requires a draft between 0.06\" and 0.1\" water column; for drafts above 0.1\" WC, HearthStone directs installation of a stovepipe damper.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eHearthStone publishes a heating area of up to a maximum of 2,500 square feet and a maximum heat output of 80,000 BTU per hour of maple cordwood. Under EPA Method 28 test conditions using Douglas Fir crib wood, the Model 8681 delivered heat at rates ranging from 14,846 to 33,424 BTU (output). HearthStone states in the current owner's manual that the Green Mountain 80 should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.\u003c\/p\u003e\n\u003ch4\u003eEveryday Controls\u003c\/h4\u003e\n\u003cp\u003eA single primary air lever under the ash lip regulates the burn rate, a bypass handle controls catalyst engagement, and a catalyst thermometer shows when the stove is in the active temperature range. The front door is operated by a wood handle, and the primary air control will not close completely, so the minimum allowable airflow is always maintained.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finish and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe Green Mountain 80 Model 8681 is currently orderable in one configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8681-0010\u003c\/td\u003e\n\u003ctd\u003e$4,799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e The price shown is the current manufacturer-suggested retail price for the stove. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8681\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2, three required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 2,500 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e80,000 BTU per hour of maple cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e14,846 to 33,424 BTU (output) under specific test conditions, using Douglas Fir crib wood per the Method 28 loading parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 30 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical operating range\u003c\/th\u003e\n\u003ctd\u003e800°F to 1300°F catalyst temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e3.15 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 23\" (58.4 cm), left to right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification test log length\u003c\/th\u003e\n\u003ctd\u003e19¾\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e32¾\" (83 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e29½\" (75 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e25\" (63 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e550 lbs (250 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 40\" x W 41\" x L 31\" (102 x 104 x 79 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop or rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (153 mm) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (153 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney; 6\" (153 mm) round flue or 7\" x 7\" (178 x 178 mm) square flue per the specification table. HearthStone requires a 6\" inside diameter flue for new installations and recommends a maximum 6\" diameter or 6\" x 6\" tile size for best results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum chimney height, top exit\u003c\/th\u003e\n\u003ctd\u003e16 feet (4.9 m) off the floor, or 13 feet 5 inches (4.1 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum chimney height, rear exit\u003c\/th\u003e\n\u003ctd\u003e19 feet (5.8 m) off the floor, or 16 feet 5 inches (5.0 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum chimney height\u003c\/th\u003e\n\u003ctd\u003e30 feet (9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; drafts above 0.1\" WC require a stovepipe damper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 96-53400, minimum 3\" (76 mm) diameter duct supplied by others; optional 3\" to 4\" duct adapter, kit 90-53308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation type\u003c\/th\u003e\n\u003ctd\u003eFreestanding room heater only. Per the current owner's manual, the stove is not to be installed in any factory-built fireplace, or any fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved when installed in accordance with 24 CFR Part 3280 and the manufacturer's special mobile home requirements described below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e80% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e0.53 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60 where applicable, using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification report\u003c\/th\u003e\n\u003ctd\u003ePFS Report F24-314\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 22.8 g\/hr, Category 2 (medium low) 11.7 g\/hr, Category 3 (medium high) 1.7 g\/hr, Category 4 41.2 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to ULC Std. S627-2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Green Mountain 80 Model 8681 owner's manual, 6400-40100 (revision 5\/30\/2025). Dimensions are measured from the edge of the top cast iron unless otherwise indicated, with a straight stovepipe directly through the ceiling. Reduced rear clearances require the HearthStone rear heat shield, kit 5968-011. Double-wall connector figures shown by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eSide — edge of top casting to side wall\u003c\/th\u003e\n\u003cth\u003eRear — edge of top casting to rear wall\u003c\/th\u003e\n\u003cth\u003eConnector centerline to rear wall\u003c\/th\u003e\n\u003cth\u003eConnector centerline to side wall\u003c\/th\u003e\n\u003cth\u003eCorner — edge of top casting to corner wall\u003c\/th\u003e\n\u003cth\u003eCorner — connector centerline to corner wall\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States — single-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e15½\" (394 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States — single-wall connector with rear heat shield 5968-011\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e5½\" (140 mm)\u003c\/td\u003e\n\u003ctd\u003e11\" (280 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States — double-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e15½\" (394 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States — double-wall connector with rear heat shield 5968-011\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e3½\" (89 mm)\u003c\/td\u003e\n\u003ctd\u003e9\" (229 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada — single-wall connector with rear heat shield (Canadian requirement)\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e15½\" (394 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove — single-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e15½\" (394 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove — single-wall connector with rear heat shield 5968-011\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e5½\" (140 mm)\u003c\/td\u003e\n\u003ctd\u003e11\" (280 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove — double-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e15½\" (394 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove — double-wall connector with rear heat shield 5968-011\u003c\/td\u003e\n\u003ctd\u003e17½\" (445 mm)\u003c\/td\u003e\n\u003ctd\u003e5½\" (140 mm)\u003c\/td\u003e\n\u003ctd\u003e11\" (280 mm)\u003c\/td\u003e\n\u003ctd\u003e32\" (813 mm)\u003c\/td\u003e\n\u003ctd\u003e7½\" (191 mm)\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn Canada, single-wall connector installations with the rear heat shield keep the unshielded clearances shown above because of connector pipe minimum-clearance requirements; the reduced U.S. rear values do not apply. The rear heat shield reduces only the rear and connector-to-rear-wall values shown in the manual tables; side and corner clearances are unchanged. The minimum unprotected ceiling height for all vertical-exit installations is 92⅜\" (234.6 cm).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove, trim, and mantel clearances, unprotected surfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e64½\" (163.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, single-wall connector\u003c\/td\u003e\n\u003ctd\u003e83⅜\" (211.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, double-wall connector\u003c\/td\u003e\n\u003ctd\u003e83⅜\" (211.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove side clearance\u003c\/td\u003e\n\u003ctd\u003e17½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnshielded mantel height from floor\u003c\/td\u003e\n\u003ctd\u003e68⅜\" (173.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel reference projection, from the front of the stove as shown in the manual figure\u003c\/td\u003e\n\u003ctd\u003e28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe centerline to front of stove, reference dimension\u003c\/td\u003e\n\u003ctd\u003e15⅞\" (403 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 83⅜\" alcove ceiling height applies to alcove installations; it is a different requirement from the 92⅜\" minimum unprotected ceiling height for vertical-exit installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRear-exit installation clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe values below apply to a through-the-wall flue exit using an elbow directly atop the stove to a rear exit, or using the stove's rear exit. The manual publishes the same values for single-wall and double-wall rear-exit pipe.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eBack wall to center of pipe\u003c\/th\u003e\n\u003cth\u003eBack wall to edge of pipe\u003c\/th\u003e\n\u003cth\u003eBack wall to edge of top casting\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith rear heat shield 5968-011 — United States\u003c\/td\u003e\n\u003ctd\u003e11\" (280 mm)\u003c\/td\u003e\n\u003ctd\u003e8\" (204 mm)\u003c\/td\u003e\n\u003ctd\u003e5½\" (140 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith rear heat shield 5968-011 — Canada\u003c\/td\u003e\n\u003ctd\u003e11\" (280 mm)\u003c\/td\u003e\n\u003ctd\u003e8\" (204 mm)\u003c\/td\u003e\n\u003ctd\u003e5½\" (140 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo rear heat shield — United States\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003ctd\u003e18\" (458 mm)\u003c\/td\u003e\n\u003ctd\u003e15½\" (394 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo rear heat shield — Canada\u003c\/td\u003e\n\u003ctd\u003e21\" (534 mm)\u003c\/td\u003e\n\u003ctd\u003e18\" (458 mm)\u003c\/td\u003e\n\u003ctd\u003e15½\" (394 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePipe clearances apply to all sides of the connection pipe. Single-wall connector pipe generally requires 18\" of clearance, including to the ceiling; for double-wall pipe clearance to the ceiling, refer to the pipe manufacturer's specifications. Use the parallel clearances above for the stove's side-wall requirements in rear-exit installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material. The Green Mountain 80 does not require an insulated hearth pad and there is no R-value requirement; the requirement is ember protection. The stove is compliant to CAN\/ULC-S627 for installation directly over a combustible floor with proper ember protection, and radiant floor insulation protection is not required.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry\u003c\/th\u003e\n\u003cth\u003eMinimum Floor Protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003ctd\u003e38\" W x 36½\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003e45½\" W x 46¼\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Extension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003ctd\u003eFront extension, from the firebox-door opening\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003ctd\u003eSide extension, from the firebox opening\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnited States and Canada\u003c\/td\u003e\n\u003ctd\u003eHearth edge to chimney connector pipe, rear area\u003c\/td\u003e\n\u003ctd\u003e2\" (51 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003eFront extension, from the firebox-door opening\u003c\/td\u003e\n\u003ctd\u003e18\" (457 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003eSide extension, from the side of the stove\u003c\/td\u003e\n\u003ctd\u003e8\" (203 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003eRear extension, from the rear of the stove body\u003c\/td\u003e\n\u003ctd\u003e8\" (203 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used. Clearances to combustible surfaces may be reduced using an NFPA 211 approved wall protection system with the additional approval of the regulatory authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMobile and manufactured home installation:\u003c\/strong\u003e The Model 8681 may be installed in a mobile home subject to the manufacturer's special requirements, including installation in accordance with 24 CFR Part 3280 (HUD); use of the outside air kit in all mobile home installations; permanent attachment of the stove to the floor using the shipping clips; a mobile home chimney and connector kit conforming to UL 103 or ULC S629 with a spark arrester secured to the chimney; maintaining the structural integrity of the walls, floor, ceiling, and roof; meeting the chimney height and roof-clearance requirements in the manual; and removal of the chimney when transporting the mobile home. The stove must not be installed in a sleeping room in a mobile home.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation notice:\u003c\/strong\u003e Clearances and hearth requirements vary by connector type, shielding, and installation configuration. Refer to the current Green Mountain 80 Model 8681 owner's manual and applicable local requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGreen Mountain 80-1 Model 8681 woodstove\u003c\/li\u003e\n\u003cli\u003eStone Kit A\u003c\/li\u003e\n\u003cli\u003eStone Kit B\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA separate box beneath the stove contains some of the internal parts, with an instruction sheet for installing them.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eRequired for all mobile home installations; connects the stove's air intake to a minimum 3\" duct, supplied by others.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvection Blower\u003c\/td\u003e\n\u003ctd\u003e96-57801\u003c\/td\u003e\n\u003ctd\u003e$549\u003c\/td\u003e\n\u003ctd\u003eRequires Rear Heat Shield 5968-011, which provides the attachment for the blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Heat Shield\u003c\/td\u003e\n\u003ctd\u003e5968-011\u003c\/td\u003e\n\u003ctd\u003e$189\u003c\/td\u003e\n\u003ctd\u003eRequired for blower installation; also provides the reduced rear-clearance configurations published in the current manual. Does not change side or corner clearances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eFor adapting the 3-inch outside-air connection to 4-inch duct where needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components and refractory, vermiculite panels, and baffles carry a 2-year period. Enamel finish against peeling or fading, glass, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Green Mountain 80 Model 8681 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53617276256532,"sku":"8681","price":4799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/GM80-8681_scene3_250303.webp?v=1786286312"},{"product_id":"hearthstone-stoves-green-mountain-80-8680-freestanding-wood-stove","title":"Hearthstone Stoves Green Mountain 80 8680 Wood Stove","description":"\u003ch2\u003eLarge-Firebox TruHybrid™ Heat with a Classic 8-Inch Flue\u003c\/h2\u003e\n\u003cp\u003eHearthStone's largest cast iron TruHybrid™ wood stove pairs a 3.1 cubic foot soapstone-lined firebox with 81% HHV efficiency and an 8-inch flue collar.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003e81% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.7 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e3.1 cubic foot soapstone-lined firebox accepts logs up to 23\" in length\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 24+ hours, with HeatLife™ of up to 30 hours, depending on wood, draft, and operating conditions\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 2,500 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003e8\" flue collar with an included rear heat shield\u003c\/li\u003e\n\u003cli\u003eExpansive ceramic glass window designed to show as much of the fire as possible\u003c\/li\u003e\n\u003cli\u003eApproved for U.S. mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through the catalysts for tertiary combustion. A bypass handle directs combustion products around the catalysts during startup and reloading, and through the catalysts once the catalyst thermometer shows the stove is in its active range. The Green Mountain 80 uses Applied Ceramics ACI-6M2 catalytic combustors, which require periodic inspection and eventual replacement, and typically operates in the 800°F to 1300°F catalyst range, with the catalysts becoming active around 500°F.\u003c\/p\u003e\n\u003ch4\u003eCast Iron Construction with a Soapstone-Lined Firebox\u003c\/h4\u003e\n\u003cp\u003eThe Green Mountain 80 is HearthStone's largest cast iron TruHybrid™ stove. Its firebox is lined with soapstone, which absorbs the heat of the fire and releases it gradually. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and surface fractures may appear with use without affecting stove function.\u003c\/p\u003e\n\u003ch4\u003eFull View of the Fire\u003c\/h4\u003e\n\u003cp\u003eThe window into the stove is designed to let you see as much fire as possible. The glass is a tough, clear ceramic material capable of operating at temperatures up to 2300°F, and an air-wash system helps keep it clean when the fire is kept away from the glass.\u003c\/p\u003e\n\u003ch4\u003e8-Inch Flue and Venting\u003c\/h4\u003e\n\u003cp\u003eModel 8680 has an 8\" diameter top flue outlet and requires an 8\" inside diameter flue for new prefabricated chimney installations. The owner's manual also addresses connector and chimney configurations routed from the top outlet toward and through the rear wall; the manual calls one such configuration a \"rear exit connection\" and requires a taller minimum chimney height for it, as detailed under Clearances and Hearth Requirements below. This describes vent-system routing and does not mean the stove itself has a convertible rear flue outlet. Confirm the planned venting configuration with your installer and the current owner's manual before ordering venting components.\u003c\/p\u003e\n\u003ch4\u003eEveryday Operation\u003c\/h4\u003e\n\u003cp\u003eA single primary air lever below the ash lip regulates the burn rate, the bypass handle controls catalyst engagement, and a catalyst thermometer shows when the stove is in the active temperature range. The manufacturer-set minimum low burn rate must not be altered.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eHearthStone publishes a heating area of up to a maximum of 2,500 square feet and a maximum heat output of 80,000 BTU per hour of cordwood, based on independent laboratory test results. Under specific EPA test conditions, the Green Mountain 80 has been shown to deliver heat at rates ranging from 15,069 to 33,396 BTU (output); this tested range is not the maximum cordwood output. HearthStone states in the current owner's manual that the Green Mountain 80 should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finish and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe Green Mountain 80 Model 8680 is currently orderable in one finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8680-0010\u003c\/td\u003e\n\u003ctd\u003e$4,799\u003c\/td\u003e\n\u003ctd\u003eIncludes rear heat shield; 8\" flue collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion system\u003c\/td\u003e\n\u003ctd\u003eTruHybrid™ - primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalytic combustor\u003c\/td\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU per hour of cordwood (based on independent laboratory test results)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA tested heat output range\u003c\/td\u003e\n\u003ctd\u003e15,069 to 33,396 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating area\u003c\/td\u003e\n\u003ctd\u003eUp to a maximum of 2,500 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e81% HHV weighted average (EPA Method 28R and CSA B415-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA particulate emissions\u003c\/td\u003e\n\u003ctd\u003e0.7 g\/hr, certified with crib wood to the 2020 EPA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurn time\u003c\/td\u003e\n\u003ctd\u003eUp to 24+ hrs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatLife™\u003c\/td\u003e\n\u003ctd\u003eUp to 30 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e3.1 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003eUp to 23\" (58.4 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e33\" (84 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e29-1\/2\" (75 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e24-1\/8\" (62 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e550 lbs. (250 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrate dimensions\u003c\/td\u003e\n\u003ctd\u003eH-40\" W-41\" L-31\" (102 x 104 x 79 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Chimney\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector size\u003c\/td\u003e\n\u003ctd\u003e8\" (203 mm) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetal chimney\u003c\/td\u003e\n\u003ctd\u003e8\" (203 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMasonry chimney\u003c\/td\u003e\n\u003ctd\u003e8\" (203 mm) inside diameter round flue, or 8\" x 8\" (203 x 203 mm) square flue, code-approved with flue liner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired draft\u003c\/td\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; install a stovepipe damper for drafts above 0.1\" WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCertification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety certification\u003c\/td\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to ULC Std. S627-2021 (Report F19-020)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA certification\u003c\/td\u003e\n\u003ctd\u003eCertified to the U.S. EPA 2020 particulate emissions standard using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Green Mountain 80 Model 8680 owner's manual. Always confirm your installation against the current manual, your venting manufacturer's instructions, and local codes. The Green Mountain 80 is to be installed as a freestanding room heater and is not to be installed in any factory-built fireplace.\u003c\/p\u003e\n\u003ch4\u003eHearth and Floor Protection\u003c\/h4\u003e\n\u003cp\u003eThe Green Mountain 80 does not require an insulated hearth pad, and there is no R-value requirement. Combustible flooring must be protected with a continuous layer of noncombustible material, such as tile, brick, slate, or glass, meeting the following minimums.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFloor protection measurement\u003c\/th\u003e\n\u003cth\u003eUnited States\u003c\/th\u003e\n\u003cth\u003eCanada\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall minimum floor protection (width x depth)\u003c\/td\u003e\n\u003ctd\u003e41-1\/2\" x 40\"\u003c\/td\u003e\n\u003ctd\u003e45\" x 50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront extension, measured from the edge of the fuel-door opening\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide extension\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm) from the edge of the fuel-door opening\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm) from the body of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear extension at the connector pipe area\u003c\/td\u003e\n\u003ctd\u003e2\" (6 cm)\u003c\/td\u003e\n\u003ctd\u003e2\" (6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear extension from the stove body to the rear hearth edge\u003c\/td\u003e\n\u003ctd\u003eSee overall minimum above\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eLuxury vinyl plank or tile flooring may require additional consideration and shielding; some vinyl flooring begins to warp at 110°F. Consult the flooring manufacturer.\u003c\/p\u003e\n\u003ch4\u003eClearances to Combustibles\u003c\/h4\u003e\n\u003cp\u003eThe measurements below correspond to the physical points in the manual's clearance diagram:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e - stove body\/top casting to the side wall (parallel installation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e - stove body\/top casting to the rear wall (parallel installation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC\u003c\/strong\u003e - chimney connector\/flue centerline to the rear wall (parallel installation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e - chimney connector\/flue centerline to the side wall (parallel installation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e - stove body\/top casting to the corner wall (corner installation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF\u003c\/strong\u003e - chimney connector\/flue centerline to the corner wall (corner installation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRoom installation\u003c\/th\u003e\n\u003cth\u003eA\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003cth\u003eC\u003c\/th\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003cth\u003eE\u003c\/th\u003e\n\u003cth\u003eF\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector - included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector - blower kit shield 96-57800\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector - included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector - blower kit shield 96-57800\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e5\" (13 cm)\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eAlcove Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAlcove installation\u003c\/th\u003e\n\u003cth\u003eA\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003cth\u003eC\u003c\/th\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003cth\u003eE\u003c\/th\u003e\n\u003cth\u003eF\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, single-wall connector - included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, single-wall connector - blower kit shield 96-57800\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, double-wall connector - included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, double-wall connector - blower kit shield 96-57800\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003ctd\u003e28\" (71 cm)\u003c\/td\u003e\n\u003ctd\u003e7\" (18 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5\" (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAlcove dimension\u003c\/th\u003e\n\u003cth\u003eUnprotected surfaces\u003c\/th\u003e\n\u003cth\u003eProtected surfaces\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e54.5\" (138.4 cm)\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, single-wall connector\u003c\/td\u003e\n\u003ctd\u003e61.5\" (156.2 cm)\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, double-wall connector\u003c\/td\u003e\n\u003ctd\u003e61.5\" (156.2 cm)\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eChimney Connector Clearances\u003c\/h4\u003e\n\u003cp\u003eFor a through-the-wall, top flue exit installation, the manual publishes the following, where \u003cstrong\u003eA\u003c\/strong\u003e is the stove\/rear-shield reference to the rear wall and \u003cstrong\u003eB\u003c\/strong\u003e is the vertical chimney connector to the rear wall. Connector clearances apply to all sides of the connection pipe; use the parallel clearances above for requirements at the sides of the stove.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector configuration\u003c\/th\u003e\n\u003cth\u003eA\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe - included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe - blower kit shield 96-57800\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe - included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe - blower kit shield 96-57800\u003c\/td\u003e\n\u003ctd\u003e5\" (13 cm)\u003c\/td\u003e\n\u003ctd\u003e10\" (25 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eA single-wall connector requires 18\" of clearance to an unprotected ceiling and 9\" to a ceiling protected per NFPA 211. For double-wall pipe clearance to the ceiling, refer to the pipe manufacturer's specifications.\u003c\/p\u003e\n\u003ch4\u003eTrim and Mantel Clearances\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide trim clearance\u003c\/td\u003e\n\u003ctd\u003e7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum mantel height above the floor\u003c\/td\u003e\n\u003ctd\u003e59.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel depth\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrim thickness shown in the manual figure\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese trim and mantel clearances also apply when the stove is positioned in an applicable masonry fireplace opening; however, the Green Mountain 80 Model 8680 is not approved for installation in a factory-built fireplace. For ceiling requirements, refer to the applicable connector and ceiling clearance requirements above.\u003c\/p\u003e\n\u003ch4\u003eChimney Requirements and Draft\u003c\/h4\u003e\n\u003cp\u003eThe Green Mountain 80 must be connected to a listed Type HT (2100°F) chimney per UL 103 or ULC S629, or to a code-approved masonry chimney with a flue liner. The chimney size should not be less than the flue collar, or more than three times greater than the cross-sectional area of the flue collar. The Green Mountain 80 requires an 8\" inside diameter flue for new prefabricated chimney installations; for masonry, use a maximum 8\" diameter or 8\" x 8\" tile size for best results. Do not connect this stove to a flue serving another appliance.\u003c\/p\u003e\n\u003cp\u003eThe recommended minimum chimney height for a top-of-stove installation is 16 feet (4.9 m) off the floor, or 13 feet 5 inches (4.1 m) from the top of the stove. For the manual's \"rear exit connection\" configuration, in which the connector and chimney are routed toward and through the rear wall, the recommended minimum chimney height is 19 feet (5.8 m) off the floor, or 16 feet 5 inches (5.0 m) from the top of the stove. The recommended maximum chimney height is 30 feet (9 m). The stove requires a draft between 0.06\" and 0.1\" water column; for drafts above 0.1\" WC, install a stovepipe damper. The chimney must also extend at least 3 feet above the highest part of the roof opening through which it passes, and at least 2 feet higher than any part of the roof within 10 feet measured horizontally.\u003c\/p\u003e\n\u003ch4\u003eOutside Air\u003c\/h4\u003e\n\u003cp\u003eThe optional outside air kit 96-53400 allows direct connection of the stove's air intake to a minimum 3\" (76 mm) diameter duct, supplied by others, leading to the outside of the house. An adapter for 4\" duct, kit 90-53308, is available if needed. Outside air is required for all mobile home installations, and may be advisable in tightly sealed homes; it is not universally mandatory for every residential installation. In Canada, when an outside air kit is used, the stove must be attached to the home's floor and a damper allowing 100% closure should be installed. The outside air duct should terminate at or below the level of the stove's air intake, screened with 1\/4\" x 1\/4\" mesh and protected with a rain- and wind-proof hood.\u003c\/p\u003e\n\u003ch4\u003eMobile and Manufactured Homes\u003c\/h4\u003e\n\u003cp\u003eThe Green Mountain 80 Model 8680 may be installed in a mobile home only when the manual's special requirements are followed. Principal conditions include: installation in accordance with 24 CFR Part 3280 (HUD); use of the outside air kit; permanent attachment of the stove to the floor using the shipping clips; installation of a Mobile Home Chimney and Connector Kit conforming to UL 103 or CAN\/ULC-S629, including a stainless spark arrester cap; no installation in a sleeping room; maintaining the structural integrity of the home's walls, floor, ceiling, and roof; meeting the roof and chimney-height requirements in the manual; and removal of the chimney when transporting the mobile home. Refer to the current owner's manual for the complete requirements.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGreen Mountain 80 Model 8680 wood stove\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003cli\u003eRear heat shield (part 5680-024, listed as included in the current manual parts list)\u003c\/li\u003e\n\u003cli\u003eA separate box beneath the stove contains internal parts, with an instruction sheet for installing them\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cp\u003eAll accessories are sold separately.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eConnects the air intake to a minimum 3\" duct (duct supplied by others); required for mobile home installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower \u0026amp; Heatshield Combo for GM80\u003c\/td\u003e\n\u003ctd\u003e96-57800\u003c\/td\u003e\n\u003ctd\u003e$649\u003c\/td\u003e\n\u003ctd\u003eConvection blower with rear heat shield; with double-wall connector pipe, reduces the rear clearance per the manual's clearance tables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eAdapter used with outside air kit 96-53400 when 4\" outside-air duct is needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the Green Mountain 80 to the original retail purchaser against defects in material or workmanship when the appliance is purchased from and installed by an authorized HearthStone dealer or their designated representative. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone and to cast iron not listed elsewhere. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period. Enamel finish against peeling or fading, glass, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Green Mountain 80 Model 8680 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53618537890068,"sku":"8680","price":4799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/GM808680_NB_200515.webp?v=1786322808"},{"product_id":"hearthstone-stoves-green-mountain-60-freestanding-wood-stove","title":"Hearthstone Stoves Green Mountain 60 Freestanding Wood Stove","description":"\u003ch2\u003eLong, Steady Soapstone Heat in a Mid-Size TruHybrid Wood Stove\u003c\/h2\u003e\u003cp\u003eThe HearthStone Green Mountain 60 Model 8660 pairs a cast iron body with a soapstone-lined firebox and TruHybrid catalytic combustion for clean, extended heat in mid-size spaces.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTruHybrid combustion\u003c\/strong\u003e combining primary, secondary, and catalytic tertiary stages, EPA certified at 0.6 g\/hr\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e79% HHV weighted-average efficiency\u003c\/strong\u003e measured per EPA Method 28R and CSA B415-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 60,000 BTU\/hr\u003c\/strong\u003e maximum heat output burning cordwood, heating up to a maximum of 2,000 square feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurn time of up to 24+ hours\u003c\/strong\u003e and HeatLife of up to 30 hours, per the current owner’s manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoapstone firebox lining\u003c\/strong\u003e that stores heat from the fire and releases gentle radiant warmth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge ceramic glass window\u003c\/strong\u003e framing a wide view of the fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6-inch top flue outlet\u003c\/strong\u003e with an included rear heat shield\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct Features\u003c\/h3\u003e\u003ch4\u003eA Stove With A View\u003c\/h4\u003e\u003cp\u003eThe clean yet traditional styling of the GM60 frames a wide view into the firebox. The cast iron body carries contemporary lines that suit a range of interiors, while the large glass window lets you enjoy the fire from across the room.\u003c\/p\u003e\u003ch4\u003eTruHybrid Combustion Technology\u003c\/h4\u003e\u003cp\u003eThe TruHybrid system combines primary and secondary combustion with tertiary combustion through a catalytic combustor to burn smoke and remaining particles for an ultra clean burn that surpasses 2020 EPA standards. A bypass handle routes combustion products around the catalyst during startup and reloading, and a catalyst thermometer indicates when the stove is in the active range. The stove typically operates in the 800 °F to 1300 °F catalyst range.\u003c\/p\u003e\u003ch4\u003eSoapstone Firebox Lining\u003c\/h4\u003e\u003cp\u003eThe GM60 firebox is lined with soapstone blocks that absorb the high heat of the fire and radiate it back gradually. HearthStone calls this extended heat release HeatLife. Under the right conditions, you will be able to start a new fire with kindling up to the end of the product’s HeatLife.\u003c\/p\u003e\u003ch4\u003eExtended Burns\u003c\/h4\u003e\u003cp\u003eThe current owner’s manual publishes a burn time of up to 24+ hours and a HeatLife of up to 30 hours. Burn the stove low and slow, then add wood to stoke it up again. Actual performance depends on fuel type, moisture content, packing density, draft, and other installation and operating conditions. The manual notes the stove should not be considered the primary heat source for your home.\u003c\/p\u003e\u003ch3\u003eAvailable Finish and Configuration\u003c\/h3\u003e\u003cp\u003eThe Green Mountain 60 is currently offered in one configuration. Pricing shown is manufacturer suggested retail pricing.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003eExterior configuration\u003c\/th\u003e\n\u003cth\u003eLoading configuration\u003c\/th\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eIncluded equipment\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003eCast iron, black matte finish with soapstone-lined firebox\u003c\/td\u003e\n\u003ctd\u003eFront load\u003c\/td\u003e\n\u003ctd\u003eWood\u003c\/td\u003e\n\u003ctd\u003e8660-0010\u003c\/td\u003e\n\u003ctd\u003e$3,899\u003c\/td\u003e\n\u003ctd\u003eStove, owner’s manual, included rear heat shield 5660-024, and parts box\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion system\u003c\/td\u003e\n\u003ctd\u003eTruHybrid: primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalytic combustor\u003c\/td\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2 FIRECAT steel combustor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output\u003c\/td\u003e\n\u003ctd\u003eUp to 60,000 BTU\/hr of cordwood (based on independent laboratory test results)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA tested heat output range\u003c\/td\u003e\n\u003ctd\u003e12,600 to 33,600 BTU (output, under specific test conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity\u003c\/td\u003e\n\u003ctd\u003eUp to a maximum of 2,000 sq. ft. (factors unique to your home can reduce this)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e79% HHV weighted-average (EPA Method 28R and CSA B415-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA certified emissions\u003c\/td\u003e\n\u003ctd\u003e0.6 g\/hr (2020 particulate standard, crib wood)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurn time\u003c\/td\u003e\n\u003ctd\u003eUp to 24+ hrs. (per current owner’s manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatLife\u003c\/td\u003e\n\u003ctd\u003eUp to 30 hours (per current owner’s manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e2.0 cubic feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003eUp to 18” (45.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e31 1\/2” (80.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e26” (66.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e21 1\/4” (54.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e450 lbs. (204 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet\u003c\/td\u003e\n\u003ctd\u003e6” (152 mm) diameter, top exit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetal chimney\u003c\/td\u003e\n\u003ctd\u003e6” (152 mm) inside diameter, Type HT (UL 103 \/ ULC S629)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMasonry chimney\u003c\/td\u003e\n\u003ctd\u003e6” (152 mm) inside diameter round flue or 8” x 8” (203 x 203 mm) square flue, code-approved with liner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eConforms to UL 1482-2022; certified to ULC S627-2021 (PFS File F20-632)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eThe appliance has a 6-inch top flue outlet. The owner’s manual addresses connector and chimney systems routed toward and through the rear wall; its rear exit connection terminology refers to the venting route, not a convertible rear appliance outlet.\u003c\/p\u003e\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\u003cp\u003eThe values below are from the current Green Mountain 60 owner’s manual. Always follow the manual, your connector and chimney manufacturers’ instructions, and local codes. Dimensions are from the body of the stove unless otherwise indicated.\u003c\/p\u003e\u003ch4\u003eHearth and Floor Protection\u003c\/h4\u003e\u003cp\u003eCombustible flooring must be protected with a continuous covering of noncombustible material such as tile, brick, slate, or glass. The Green Mountain 60 does not require an insulated hearth pad, and there is no R-value requirement.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eUnited States\u003c\/th\u003e\n\u003cth\u003eCanada\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall minimum floor protection (width x depth)\u003c\/td\u003e\n\u003ctd\u003e33 1\/4” x 33 1\/2” (85 x 86 cm)\u003c\/td\u003e\n\u003ctd\u003e42” x 43 1\/2” (107 x 111 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront extension, from edge of fuel-door opening\u003c\/td\u003e\n\u003ctd\u003e16” (41 cm)\u003c\/td\u003e\n\u003ctd\u003e18” (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide extension\u003c\/td\u003e\n\u003ctd\u003e8” (21 cm), from edge of fuel-door opening to edge of hearth\u003c\/td\u003e\n\u003ctd\u003e8” (21 cm), from body of stove to edge of hearth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear pipe-area protection\u003c\/td\u003e\n\u003ctd\u003e2” (6 cm)\u003c\/td\u003e\n\u003ctd\u003e2” (6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear extension, from body of stove to edge of hearth\u003c\/td\u003e\n\u003ctd\u003eSee overall protection above\u003c\/td\u003e\n\u003ctd\u003e8” (21 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eInstallations over Luxury Vinyl Plank or Luxury Vinyl Tile flooring require extra consideration; consult the flooring manufacturer for maximum temperature recommendations.\u003c\/p\u003e\u003ch4\u003eClearance to Combustibles (Parallel and Corner Installations)\u003c\/h4\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eStove body to side wall\u003c\/th\u003e\n\u003cth\u003eStove body to rear wall\u003c\/th\u003e\n\u003cth\u003eFlue centerline to rear wall\u003c\/th\u003e\n\u003cth\u003eFlue centerline to side wall\u003c\/th\u003e\n\u003cth\u003eStove body to corner wall\u003c\/th\u003e\n\u003cth\u003eFlue centerline to corner wall\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13” (33 cm)\u003c\/td\u003e\n\u003ctd\u003e11” (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16” (41 cm)\u003c\/td\u003e\n\u003ctd\u003e26” (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7” (18 cm)\u003c\/td\u003e\n\u003ctd\u003e18.5” (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e13” (33 cm)\u003c\/td\u003e\n\u003ctd\u003e11” (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16” (41 cm)\u003c\/td\u003e\n\u003ctd\u003e26” (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7” (18 cm)\u003c\/td\u003e\n\u003ctd\u003e18.5” (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13” (33 cm)\u003c\/td\u003e\n\u003ctd\u003e11” (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16” (41 cm)\u003c\/td\u003e\n\u003ctd\u003e26” (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7” (18 cm)\u003c\/td\u003e\n\u003ctd\u003e18.5” (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e13” (33 cm)\u003c\/td\u003e\n\u003ctd\u003e5” (13 cm)\u003c\/td\u003e\n\u003ctd\u003e10” (26 cm)\u003c\/td\u003e\n\u003ctd\u003e26” (66 cm)\u003c\/td\u003e\n\u003ctd\u003e7” (18 cm)\u003c\/td\u003e\n\u003ctd\u003e18.5” (47 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13” (33 cm)\u003c\/td\u003e\n\u003ctd\u003e17.5” (45 cm)\u003c\/td\u003e\n\u003ctd\u003e21” (53 cm)\u003c\/td\u003e\n\u003ctd\u003e26” (66 cm)\u003c\/td\u003e\n\u003ctd\u003e10” (26 cm)\u003c\/td\u003e\n\u003ctd\u003e20.5” (52 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch4\u003eAlcove Installation\u003c\/h4\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eStove body to side wall\u003c\/th\u003e\n\u003cth\u003eStove body to rear wall\u003c\/th\u003e\n\u003cth\u003eFlue centerline to rear wall\u003c\/th\u003e\n\u003cth\u003eFlue centerline to side wall\u003c\/th\u003e\n\u003cth\u003eStove body to corner wall\u003c\/th\u003e\n\u003cth\u003eFlue centerline to corner wall\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, single-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13”\u003c\/td\u003e\n\u003ctd\u003e11”\u003c\/td\u003e\n\u003ctd\u003e16”\u003c\/td\u003e\n\u003ctd\u003e26”\u003c\/td\u003e\n\u003ctd\u003e7”\u003c\/td\u003e\n\u003ctd\u003e18.5”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, single-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e13”\u003c\/td\u003e\n\u003ctd\u003e11”\u003c\/td\u003e\n\u003ctd\u003e16”\u003c\/td\u003e\n\u003ctd\u003e26”\u003c\/td\u003e\n\u003ctd\u003e7”\u003c\/td\u003e\n\u003ctd\u003e18.5”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, double-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13”\u003c\/td\u003e\n\u003ctd\u003e11”\u003c\/td\u003e\n\u003ctd\u003e16”\u003c\/td\u003e\n\u003ctd\u003e26”\u003c\/td\u003e\n\u003ctd\u003e7”\u003c\/td\u003e\n\u003ctd\u003e18.5”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, double-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e13”\u003c\/td\u003e\n\u003ctd\u003e11”\u003c\/td\u003e\n\u003ctd\u003e16”\u003c\/td\u003e\n\u003ctd\u003e26”\u003c\/td\u003e\n\u003ctd\u003e7”\u003c\/td\u003e\n\u003ctd\u003e18.5”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAlcove requirement\u003c\/th\u003e\n\u003cth\u003eUnprotected surfaces\u003c\/th\u003e\n\u003cth\u003eProtected surfaces (NFPA 211)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e52” (132.1 cm)\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, single-wall connector\u003c\/td\u003e\n\u003ctd\u003e61.5” (156.2 cm)\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, double-wall connector\u003c\/td\u003e\n\u003ctd\u003e61.5” (156.2 cm)\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch4\u003eChimney Connector Clearances (Through-the-Wall, Top Flue Exit)\u003c\/h4\u003e\u003cp\u003eConnector clearances apply to all sides of the connection pipe. For stove side-wall requirements, use the parallel clearances above.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eRear of stove to rear combustible wall\u003c\/th\u003e\n\u003cth\u003eVertical connector centerline to rear combustible wall\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e11” (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16” (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e11” (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16” (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e11” (28 cm)\u003c\/td\u003e\n\u003ctd\u003e16” (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, blower kit shield 96-57400\u003c\/td\u003e\n\u003ctd\u003e5” (13 cm)\u003c\/td\u003e\n\u003ctd\u003e10” (26 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConnector ceiling clearance\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector to unprotected ceiling\u003c\/td\u003e\n\u003ctd\u003e18”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector to protected ceiling\u003c\/td\u003e\n\u003ctd\u003e9”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector to ceiling\u003c\/td\u003e\n\u003ctd\u003eRefer to the pipe manufacturer’s specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch4\u003eTrim and Mantel Clearances\u003c\/h4\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide trim clearance\u003c\/td\u003e\n\u003ctd\u003e5”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel height above floor\u003c\/td\u003e\n\u003ctd\u003e48”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel depth\u003c\/td\u003e\n\u003ctd\u003e12”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrim thickness shown\u003c\/td\u003e\n\u003ctd\u003e4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeiling\u003c\/td\u003e\n\u003ctd\u003eRefer to the applicable connector and ceiling requirements above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eThese trim and mantel clearances also apply when the stove is positioned in an applicable masonry fireplace opening; however, the Green Mountain 60 Model 8660 is to be installed as a freestanding room heater and is not approved for installation in any factory-built fireplace.\u003c\/p\u003e\u003ch4\u003eChimney Height and Draft\u003c\/h4\u003e\u003cp\u003eThe recommended minimum chimney height for a top-of-stove installation is 16 feet (4.9 m) off the floor, or 13 feet 6 1\/8 inches (4.3 m) from the top of the stove. For the manual’s rear exit connection vent-routing configuration, the recommended minimum chimney height is 19 feet (5.8 m) off the floor, or 16 feet 6 1\/8 inches (5.2 m) from the top of the stove. The recommended maximum chimney height is 30 feet (9 m). Proper chimney draft is required for safe, efficient operation; chimney sizing and installation must follow the current Model 8660 owner’s manual and the applicable chimney manufacturer’s requirements, and a stovepipe damper may be necessary where an installation produces excessive draft. The chimney must be at least 3 feet higher than the highest part of the roof opening through which it passes and at least 2 feet higher than any part of the roof within 10 feet, measured horizontally.\u003c\/p\u003e\u003ch4\u003eOutside Air\u003c\/h4\u003e\u003cp\u003eAn optional Outside Air Kit 96-53400 allows direct connection of the stove’s air intake to a minimum 3” (76 mm) diameter duct, supplied by others, leading outside the house. An adapter for 4” duct is available, Kit 90-53308. When using an outside air kit in Canada, the stove must be attached to the home’s floor using the shipping clips that came with the stove and fasteners long enough to attach securely to the subfloor. Outside air is required for all mobile-home installations.\u003c\/p\u003e\u003ch4\u003eMobile and Manufactured Home Installation\u003c\/h4\u003e\u003cp\u003eThe Green Mountain 60 may be installed in a mobile or manufactured home subject to special requirements, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInstall in accordance with 24 CFR Part 3280 (HUD)\u003c\/li\u003e\n\u003cli\u003eAn outside air kit must be used in all mobile-home installations\u003c\/li\u003e\n\u003cli\u003ePermanently attach the stove to the floor using the shipping clips and appropriate fasteners\u003c\/li\u003e\n\u003cli\u003eInstall a Mobile Home Chimney and Connector Kit conforming to UL 103 or ULC S629, including a stainless spark arrester cap\u003c\/li\u003e\n\u003cli\u003eDo not install in a sleeping room\u003c\/li\u003e\n\u003cli\u003eMaintain the structural integrity of the walls, floor, ceiling, and roof\u003c\/li\u003e\n\u003cli\u003eEnsure adequate combustion air is available\u003c\/li\u003e\n\u003cli\u003eRemove the chimney when transporting the mobile home\u003c\/li\u003e\n\u003cli\u003eMaintain an effective vapor barrier where the chimney or other components penetrate the exterior of the structure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGreen Mountain 60 Model 8660 woodstove\u003c\/li\u003e\n\u003cli\u003eOwner’s manual\u003c\/li\u003e\n\u003cli\u003eParts box with internal parts and instruction sheet (shipped beneath the stove)\u003c\/li\u003e\n\u003cli\u003eRear heat shield 5660-024 (included; distinct from the reduced-clearance heatshield supplied with the optional blower kit 96-57400)\u003c\/li\u003e\n\u003cli\u003eShipping clips (used for floor attachment where required)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\u003cp\u003eAccessories are sold separately. Pricing shown is manufacturer suggested retail pricing.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or requirement note\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower \u0026amp; Reduced Clearance Heatshield Combo\u003c\/td\u003e\n\u003ctd\u003e96-57400\u003c\/td\u003e\n\u003ctd\u003e$649\u003c\/td\u003e\n\u003ctd\u003eConvection blower with rear heat shield; moves air up and across the stove and enables the reduced clearances listed for the blower kit shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eConnects the stove’s air intake to a minimum 3” outside-air duct (ducting supplied by others); required for all mobile-home installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3” to 4” Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eAdapter used with 96-53400 when a 4” outside-air duct is needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003eHearthStone covers the Green Mountain 60 under its limited warranty to the original retail purchaser when the appliance is purchased from and installed by an authorized HearthStone dealer or their designated representative. Coverage periods vary by component: stone and cast iron components not listed elsewhere carry a Limited Lifetime warranty, defined as 10 years from the beginning of coverage; door handles, latches, and steel components and firebox are covered for 5 years; enamel finish, accessories, and glass are covered for 1 year. The Applied Ceramics FIRECAT catalytic combustor is warranted directly by Applied Ceramics with a two-year replacement provision and a prorated schedule thereafter. Exclusions and conditions apply, including damage from over-firing or improper installation. See the owner’s manual for complete warranty terms and registration instructions.\u003c\/p\u003e\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\u003cp\u003eHearthstone Quality Home Heating Products, Inc. is based in Morrisville, Vermont, where it has built soapstone and cast iron heating products for decades. Each stove is handcrafted from precision-made components in cast iron, soapstone, steel, ceramic, and other materials. Visit our showroom to see the Green Mountain 60 and speak with our team about your installation.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53622785704212,"sku":"8660","price":3899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/GM60-8660_C_230207.webp?v=1786408570"},{"product_id":"hearthstone-stoves-green-mountain-40-freestanding-wood-stove","title":"Hearthstone Stoves Green Mountain 40 Freestanding Wood Stove","description":"\u003ch2\u003eCompact Cast Iron Wood Stove with TruHybrid™ Catalytic Combustion and a Soapstone-Lined Firebox\u003c\/h2\u003e\n\u003cp\u003eTraditional black cast iron construction with a soapstone-lined firebox, TruHybrid™ catalytic combustion, 79% HHV efficiency, and heating coverage of up to 1,400 square feet.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTruHybrid™ combustion\u003c\/strong\u003e combining primary, secondary, and catalytic tertiary stages for a clean, efficient burn\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e79% HHV efficiency\u003c\/strong\u003e with EPA-certified emissions of 1.07 g\/hr\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats up to 1,400 sq. ft.\u003c\/strong\u003e, depending on home layout, insulation, and operating conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.32 cu. ft. soapstone-lined firebox\u003c\/strong\u003e accepting logs up to 16 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurn time of up to 16+ hours\u003c\/strong\u003e and HeatLife™ of up to 20 hours, per the current owner's manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded rear heat shield\u003c\/strong\u003e for reduced rear clearances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge ceramic glass window\u003c\/strong\u003e with an air-wash system for fire viewing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMobile-home approved\u003c\/strong\u003e when installed per the owner's manual, with the outside air kit required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Catalytic Combustion\u003c\/h4\u003e\n\u003cp\u003eThe Green Mountain 40 pairs primary and secondary combustion with a tertiary catalytic stage. The stainless steel catalytic combustor becomes active at approximately 500°F and burns smoke and remaining particles that were not fully consumed in the firebox, so a well-established fire produces little to no visible smoke from the chimney. The stove typically operates in the 800°F to 1,300°F catalyst range.\u003c\/p\u003e\n\u003ch4\u003eSoapstone-Lined Firebox\u003c\/h4\u003e\n\u003cp\u003eThe firebox is lined with natural soapstone blocks. Soapstone absorbs the high heat of the fire and then radiates gentle, even warmth into the room, extending comfortable heat well after the flames die down.\u003c\/p\u003e\n\u003ch4\u003eCast Iron Construction\u003c\/h4\u003e\n\u003cp\u003eThe GM40 is styled with clean lines in traditional black cast iron and is built from precision-made cast iron, soapstone, steel, and ceramic components. The 2026 HearthStone catalog identifies the Green Mountain family as EPA-certified room heaters made in Vermont.\u003c\/p\u003e\n\u003ch4\u003eSimple, Direct Controls\u003c\/h4\u003e\n\u003cp\u003eA single primary air control under the ash lip regulates the burn rate, a bypass handle routes combustion products through or around the catalyst, and a catalyst thermometer indicates when the stove is in the active catalytic range.\u003c\/p\u003e\n\u003ch4\u003eOptional Convection Blower with Reduced-Clearance Heat Shield\u003c\/h4\u003e\n\u003cp\u003eThe optional Blower \u0026amp; Reduced Clearance Heatshield Combo (96-57400) moves air up and across the stove to circulate more heat into the room. A snap switch turns the blower on automatically, and a rheostat adjusts its speed. The kit's shield supports the reduced-clearance configurations published in the owner's manual.\u003c\/p\u003e\n\u003ch4\u003eOutside Air Capability\u003c\/h4\u003e\n\u003cp\u003eThe optional Outside Air Starter (96-53400) connects the stove's air intake to a minimum 3-inch duct (ducting and termination supplied by others) so combustion air is drawn from outside the home. A 3-inch to 4-inch increaser (90-53308) is available when a 4-inch duct is needed. Outside air is required in all mobile-home installations, and Canadian outside-air installations require the stove to be attached to the floor and a damper allowing 100% closure.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finish and Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003eExterior\u003c\/th\u003e\n\u003cth\u003eLoading\u003c\/th\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eIncluded Equipment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003eBlack matte cast iron with soapstone-lined firebox\u003c\/td\u003e\n\u003ctd\u003eFront load\u003c\/td\u003e\n\u003ctd\u003eWood\u003c\/td\u003e\n\u003ctd\u003e8640-0010\u003c\/td\u003e\n\u003ctd\u003e$3,499.00\u003c\/td\u003e\n\u003ctd\u003eStove with rear heat shield and catalyst thermometer; owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion system\u003c\/td\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalytic combustor\u003c\/td\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2 stainless steel catalyst\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHHV efficiency\u003c\/td\u003e\n\u003ctd\u003e79% (weighted average, higher heating value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA-certified emissions\u003c\/td\u003e\n\u003ctd\u003e1.07 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output\u003c\/td\u003e\n\u003ctd\u003eUp to 40,000 BTU\/hr of cordwood (independent laboratory test results)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA tested heat output\u003c\/td\u003e\n\u003ctd\u003e14,000 to 24,000 BTU output under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 1,400 sq. ft.; factors unique to your home can reduce coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e1.32 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003eUp to 16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurn time\u003c\/td\u003e\n\u003ctd\u003eUp to 16+ hours (per current owner's manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatLife™\u003c\/td\u003e\n\u003ctd\u003eUp to 20 hours (per current owner's manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e30⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e23¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e19⅜\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e350 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue exit\u003c\/td\u003e\n\u003ctd\u003eTop, 6\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, 24 or 25 MSG blued steel (single wall) or listed double-wall connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney\u003c\/td\u003e\n\u003ctd\u003eListed Type HT (UL 103 \/ ULC S629) metal chimney, 6\" inside diameter, or code-approved lined masonry chimney with 6\" round or 8\" x 8\" square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural seasoned cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEPA 2020 certified; conforms to UL 1482-2022; certified to ULC S627-2021 (PFS Report F17-183)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eClearances to combustibles.\u003c\/strong\u003e Dimensions are measured from the body of the stove unless otherwise indicated; C, D, and F are chimney-connector reference dimensions. Refer to the current owner's manual for complete installation requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Configuration\u003c\/th\u003e\n\u003cth\u003eA — Side (stove body to side wall)\u003c\/th\u003e\n\u003cth\u003eB — Rear (stove body to rear wall)\u003c\/th\u003e\n\u003cth\u003eC — Connector to rear wall\u003c\/th\u003e\n\u003cth\u003eD — Connector to side wall\u003c\/th\u003e\n\u003cth\u003eE — Corner (stove body to corner wall)\u003c\/th\u003e\n\u003cth\u003eF — Corner (connector to corner wall)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle wall, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e25½\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e25½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle wall with included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e13¾\"\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003ctd\u003e25½\"\u003c\/td\u003e\n\u003ctd\u003e7\"\u003c\/td\u003e\n\u003ctd\u003e17¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle wall with blower kit heat shield (96-57400)\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e13¾\"\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003ctd\u003e25½\"\u003c\/td\u003e\n\u003ctd\u003e7\"\u003c\/td\u003e\n\u003ctd\u003e17¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble wall with included rear heat shield\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e9¾\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e25½\"\u003c\/td\u003e\n\u003ctd\u003e7\"\u003c\/td\u003e\n\u003ctd\u003e17¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble wall with blower kit heat shield (96-57400)\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e9¾\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e25½\"\u003c\/td\u003e\n\u003ctd\u003e7\"\u003c\/td\u003e\n\u003ctd\u003e17¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installations.\u003c\/strong\u003e Alcove side, rear, and connector clearances (A through D) match the corresponding shielded configurations above; corner dimensions E and F in an alcove follow NFPA 211. The minimum unprotected alcove width is 51¼\", and the minimum alcove ceiling height from the floor is 56\" with either a single-wall or double-wall connector. For protected surfaces, refer to NFPA 211 and your local authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChimney connector clearances (through-wall, top flue exit).\u003c\/strong\u003e With either the included rear heat shield or the blower kit shield installed: single-wall connector — 13¾\" from the appliance rear to the wall and 18\" from the vertical connector to the wall; double-wall connector — 9¾\" and 14\" respectively. Single-wall connector pipe requires 18\" to an unprotected ceiling or 9\" to a protected ceiling; for double-wall pipe ceiling clearance, refer to the pipe manufacturer's specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection.\u003c\/strong\u003e The Green Mountain 40 does not require an insulated hearth pad; noncombustible ember protection with no R-value requirement must cover the floor beneath and around the stove.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eUSA\u003c\/th\u003e\n\u003cth\u003eCanada\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum overall floor protection (width x depth)\u003c\/td\u003e\n\u003ctd\u003e31½\" x 33\"\u003c\/td\u003e\n\u003ctd\u003e40\" x 43\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront extension (from edge of fuel-door opening to edge of hearth)\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide extension\u003c\/td\u003e\n\u003ctd\u003e8\" from edge of fuel-door opening\u003c\/td\u003e\n\u003ctd\u003e8\" from stove body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear extension\u003c\/td\u003e\n\u003ctd\u003e0\" from stove body\u003c\/td\u003e\n\u003ctd\u003e8\" from stove body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eLuxury vinyl plank (LVP) or luxury vinyl tile (LVT) flooring requires extra consideration; some vinyl flooring begins to warp at 110°F. Consult the flooring manufacturer for maximum temperature recommendations, as additional shielding may be necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTrim and mantel.\u003c\/strong\u003e The owner's manual publishes a 6\" side trim clearance, a mantel height of 48\" from the floor with a maximum mantel depth of 12\", and a 4\" trim thickness reference. The Green Mountain 40 is a freestanding room heater and is not to be installed in any factory-built fireplace.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChimney and draft.\u003c\/strong\u003e The stove connects to a 6\" listed Type HT metal chimney or a code-approved lined masonry chimney. The recommended minimum chimney height for a top-of-stove installation is 16 feet from the floor, and the recommended maximum chimney height is 30 feet. Proper chimney draft is required for safe, efficient operation; follow the current owner's manual and the chimney manufacturer's requirements, and note that installations with excessive draft may require a stovepipe damper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMobile-home installations.\u003c\/strong\u003e Install in accordance with 24 CFR Part 3280. The outside air kit (96-53400) is required, the stove must be permanently attached to the floor using the shipping clips supplied with the stove, and a Mobile Home Chimney \u0026amp; Connector Kit conforming to UL 103 or ULC S629 must be used, including a stainless spark-arrester cap, storm collar, and adjustable vented flashing. Do not install in a sleeping room, maintain the structural integrity of the home, burn wood only, keep the front door closed during operation except for startup and loading, remove the chimney when transporting the home, and preserve the exterior vapor barrier where the chimney penetrates the structure.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGreen Mountain 40 Model 8640 woodstove with catalytic combustor, rear heat shield (5640-024), and catalyst thermometer (7200-520) installed\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003cli\u003eShipping clips (used for floor attachment in Canadian outside-air and mobile-home installations)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility \/ Requirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower \u0026amp; Reduced Clearance Heatshield Combo\u003c\/td\u003e\n\u003ctd\u003e96-57400\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003ctd\u003eOptional convection blower with heat shield; supports the reduced-clearance blower kit shield configurations in the owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109.00\u003c\/td\u003e\n\u003ctd\u003eOptional for most installations; required for all mobile-home installations; connects to a minimum 3\" duct supplied by others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49.00\u003c\/td\u003e\n\u003ctd\u003eUse with the outside air system (96-53400) when a 4\" duct connection is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Green Mountain 40 is covered by HearthStone's written limited warranty, under which the term Limited Lifetime is defined as 10 years from the start of coverage. Stone and cast iron components carry Limited Lifetime coverage, steel components and door handles and latches are covered for 5 years, and glass, accessories, and the enamel finish are covered for 1 year, with labor coverage during the first year for dealer-installed appliances. The catalytic combustor (Applied Ceramics model ACI-6M2) is warranted directly by Applied Ceramics, including no-charge replacement within the first two years and a prorated schedule thereafter. All coverage is subject to the terms, conditions, and exclusions of the current written warranty, and warranty registration is available at hearthstonestoves.com.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthstone Quality Home Heating Products, Inc. is based in Morrisville, Vermont, where the company builds soapstone and cast iron heating products designed for long, comfortable, even heat. Visit our showroom to see the Green Mountain 40 in person and talk through your installation with our team.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53635384738068,"sku":"8640","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/GM40-8640_NB_200515.webp?v=1786412302"},{"product_id":"hearthstone-stoves-green-mountain-20-freestanding-wood-stove","title":"Hearthstone Stoves Green Mountain 20 Freestanding Wood Stove","description":"\u003ch2\u003eCompact TruHybrid™ Catalytic Wood Stove Sized for Small Spaces\u003c\/h2\u003e\n\u003cp\u003eCast iron construction with a soapstone-lined firebox and TruHybrid™ catalytic combustion, the Green Mountain 20 is sized for cabins, small homes, and rooms up to 575 square feet.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTruHybrid™ combustion\u003c\/strong\u003e combining primary, secondary, and catalytic tertiary combustion with a 78.5% HHV weighted-average efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA certified at 1.14 g\/hr\u003c\/strong\u003e under the 2020 particulate emissions standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 23,000 BTU per hour\u003c\/strong\u003e of Maple cordwood, heating up to 575 square feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoapstone-lined firebox\u003c\/strong\u003e that absorbs the heat of the fire and radiates gentle, long-lasting warmth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurn times up to 9.5 hours on low\u003c\/strong\u003e, with HeatLife™ up to 20 hours per the current owner's manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurns full-size cordwood\u003c\/strong\u003e up to 18 inches long (16 inches recommended) in a slim 14.7-inch-wide body\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop 6-inch flue outlet\u003c\/strong\u003e with optional rear and side heat shields to reduce clearances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Catalytic Combustion\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system combines primary, secondary, and tertiary combustion using a catalytic combustor to deliver clean, efficient burns that surpass 2020 EPA clean air standards. The stove is certified at a 1.14 g\/hr emission rate and, under specific EPA test conditions, has been shown to deliver heat at rates ranging from 14,545 to 20,507 BTU per hour. A bypass control and a supplied catalyst temperature indicator help you engage the catalyst at the correct operating temperature for the cleanest burn.\u003c\/p\u003e\n\u003ch4\u003eSoapstone and Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003eThe Green Mountain 20 combines a cast iron body with a soapstone-lined firebox. Soapstone absorbs the high heat of the fire and then radiates a gentle heat into the room, extending comfortable warmth well after the flames die down. A large ceramic glass window provides a full view of the fire. The 2026 HearthStone catalog identifies the Green Mountain family of EPA certified room heaters as made in Vermont.\u003c\/p\u003e\n\u003ch4\u003eSized for Small Spaces\u003c\/h4\u003e\n\u003cp\u003eDesigned as a traditional log burner for tight footprints, the Green Mountain 20 heats up to a maximum of 575 square feet. Factors unique to your home, including insulation, windows, floor plan, stove placement, and fuel quality, may reduce the area the stove will heat. The 1.0 cubic foot firebox accepts cordwood up to 18 inches long, with 16-inch logs recommended.\u003c\/p\u003e\n\u003ch4\u003eHeat Shield and Outside Air Options\u003c\/h4\u003e\n\u003cp\u003eOptional rear and side heat shields can be installed individually or together to reduce required clearances to combustible walls. The optional Outside Air Starter kit connects the stove's air intake to a minimum 3-inch outside air duct (ducting supplied by others), with a 3-inch to 4-inch increaser available when a 4-inch duct is needed. An outside air kit is required in all mobile-home installations.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finish and Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8620-0010\u003c\/td\u003e\n\u003ctd\u003e$2,699\u003c\/td\u003e\n\u003ctd\u003eSole current configuration; cast iron with soapstone-lined firebox; front load; wood fuel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003eTruHybrid™ catalytic (primary, secondary, and catalytic tertiary combustion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output\u003c\/td\u003e\n\u003ctd\u003eUp to 23,000 BTU per hour of Maple cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA test-condition heat output\u003c\/td\u003e\n\u003ctd\u003e14,545 to 20,507 BTU per hour (output, specific test conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHHV efficiency\u003c\/td\u003e\n\u003ctd\u003e78.5% (weighted average, higher heating value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA certified emissions\u003c\/td\u003e\n\u003ctd\u003e1.14 g\/hr (2020 particulate standard, crib wood)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating area\u003c\/td\u003e\n\u003ctd\u003eUp to a maximum of 575 sq. ft.; home-specific factors may reduce coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e1.0 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003eUp to 18\" (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurn time\u003c\/td\u003e\n\u003ctd\u003eUp to 9.5 hours on low, per the current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatLife™\u003c\/td\u003e\n\u003ctd\u003eUp to 20 hours, per the current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e14.7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e24.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 lb, per the current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet\u003c\/td\u003e\n\u003ctd\u003eTop, 6\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector size\u003c\/td\u003e\n\u003ctd\u003e6\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetal chimney\u003c\/td\u003e\n\u003ctd\u003e6\" inside diameter, listed Type HT (UL 103 or ULC S629)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMasonry chimney\u003c\/td\u003e\n\u003ctd\u003e6\" round flue or 8\" x 8\" square flue, code-approved with liner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired chimney draft\u003c\/td\u003e\n\u003ctd\u003eBetween -0.06\" and -0.10\" water column; install a stovepipe damper for drafts above -0.10\" water column\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended chimney height\u003c\/td\u003e\n\u003ctd\u003e16 ft minimum to 30 ft maximum from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eConforms to UL 1482-2022; certified to CAN\/ULC S627:2023; PFS Report F25-444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural seasoned cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrate dimensions\u003c\/td\u003e\n\u003ctd\u003e40\" H x 29\" W x 36\" L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe Green Mountain 20 is a freestanding room heater only. It must not be installed into a factory-built fireplace or any fireplace.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClearance dimensions are measured from the furthest point on the cast body of the stove unless otherwise indicated. In the table below, A is the stove body side to the side wall, B is the connector to the side wall, C is the stove body rear to the rear wall, D is the connector to the rear wall, E is the stove body corner to a diagonal wall, and F is the connector corner to a diagonal wall. Optional side and rear heat shields reduce the listed clearances.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParallel installation\u003c\/th\u003e\n\u003cth\u003eA Side (stove)\u003c\/th\u003e\n\u003cth\u003eB Side (connector)\u003c\/th\u003e\n\u003cth\u003eC Rear (stove)\u003c\/th\u003e\n\u003cth\u003eD Rear (connector)\u003c\/th\u003e\n\u003cth\u003eE Corner (stove)\u003c\/th\u003e\n\u003cth\u003eF Corner (connector)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, no heat shields\u003c\/td\u003e\n\u003ctd\u003e13¾\"\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e10\" US \/ 15¼\" CAN\u003c\/td\u003e\n\u003ctd\u003e15¾\" US \/ 21\" CAN\u003c\/td\u003e\n\u003ctd\u003e9½\" US \/ 12½\" CAN\u003c\/td\u003e\n\u003ctd\u003e18\" US \/ 21\" CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, side heat shields\u003c\/td\u003e\n\u003ctd\u003e11¾\" US \/ 13¾\" CAN\u003c\/td\u003e\n\u003ctd\u003e19\" US \/ 21\" CAN\u003c\/td\u003e\n\u003ctd\u003e10\" US \/ 15¼\" CAN\u003c\/td\u003e\n\u003ctd\u003e15¾\" US \/ 21\" CAN\u003c\/td\u003e\n\u003ctd\u003e9½\" US \/ 12½\" CAN\u003c\/td\u003e\n\u003ctd\u003e18\" US \/ 21\" CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13¾\"\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e10\" US \/ 15¼\" CAN\u003c\/td\u003e\n\u003ctd\u003e15¾\" US \/ 21\" CAN\u003c\/td\u003e\n\u003ctd\u003e9½\" US \/ 12½\" CAN\u003c\/td\u003e\n\u003ctd\u003e18\" US \/ 21\" CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, all heat shields\u003c\/td\u003e\n\u003ctd\u003e11¾\" US \/ 13¾\" CAN\u003c\/td\u003e\n\u003ctd\u003e19\" US \/ 21\" CAN\u003c\/td\u003e\n\u003ctd\u003e10\" US \/ 15¼\" CAN\u003c\/td\u003e\n\u003ctd\u003e15¾\" US \/ 21\" CAN\u003c\/td\u003e\n\u003ctd\u003e9½\" US \/ 12½\" CAN\u003c\/td\u003e\n\u003ctd\u003e18\" US \/ 21\" CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, no heat shields\u003c\/td\u003e\n\u003ctd\u003e13¾\"\u003c\/td\u003e\n\u003ctd\u003e20¾\"\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003ctd\u003e14½\"\u003c\/td\u003e\n\u003ctd\u003e9½\"\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, side heat shields\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003ctd\u003e14½\"\u003c\/td\u003e\n\u003ctd\u003e9½\"\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, rear heat shield\u003c\/td\u003e\n\u003ctd\u003e13¾\"\u003c\/td\u003e\n\u003ctd\u003e20¾\"\u003c\/td\u003e\n\u003ctd\u003e3½\"\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003ctd\u003e9½\"\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, all heat shields\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003ctd\u003e3½\"\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn Canada, per CSA B365, installations with single-wall pipe require a minimum clearance of 18\" from the flue to a combustible surface, regardless of a smaller clearance noted on the product label. Double-wall connector clearances shown are specific to Simpson DuraVent DVL; check your pipe manufacturer's specifications.\u003c\/p\u003e\n\u003cp\u003eThe current owner's manual also publishes complete through-wall and alcove clearance tables. The minimum unshielded alcove width with double-wall pipe and side heat shields is 32¾\", and the minimum alcove ceiling height is 78½\" from the floor with either a single-wall or double-wall connector. Alcove and through-wall installations must follow the exact configuration tables in the manual.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eChimney connector clearance\u003c\/th\u003e\n\u003cth\u003eA\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, through-the-wall flue exit, with rear heat shield\u003c\/td\u003e\n\u003ctd\u003e17¾\" US \/ 21\" CAN\u003c\/td\u003e\n\u003ctd\u003e14¾\" US \/ 18\" CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, through-the-wall flue exit, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e16¾\" US \/ 21\" CAN\u003c\/td\u003e\n\u003ctd\u003e13¾\" US \/ 18\" CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, with rear heat shield\u003c\/td\u003e\n\u003ctd\u003e11\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, no rear heat shield\u003c\/td\u003e\n\u003ctd\u003e16¾\"\u003c\/td\u003e\n\u003ctd\u003e13¾\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSingle-wall connector clearance to the ceiling is 18\". For double-wall connector clearance to the ceiling, refer to the connector pipe manufacturer's specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection:\u003c\/strong\u003e The Green Mountain 20 does not require an insulated hearth pad and has no R-value requirement. Combustible flooring must be protected with a covering of noncombustible material. The minimum floor ember protection is 27½\" wide x 37½\" deep for US installations, including a 16\" front extension measured from the firebox front and 8\" side extensions measured from the firebox sides. For installations in Canada, the minimum is 30⅝\" wide x 47½\" deep, including an 18\" front ember-protection extension and 8\" side extensions. Rooms with luxury vinyl plank or luxury vinyl tile flooring require extra consideration, as some of these floors begin to warp at 110° Fahrenheit; consult the flooring manufacturer and add shielding if necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMobile-home installations:\u003c\/strong\u003e The stove may be installed in a mobile home in accordance with 24 CFR Part 3280, subject to special requirements in the owner's manual. These include an outside air kit in all mobile-home installations, permanent attachment of the stove to the floor, a Mobile Home Chimney and Connector Kit conforming to UL 103 or CAN\/ULC S629 with a stainless spark-arrester cap, no installation in a sleeping room, keeping the front door closed except during startup and loading, burning wood fuel only, maintaining the structural integrity and vapor barrier of the home, required chimney termination geometry, and removal of the chimney when the mobile home is transported.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGreen Mountain 20 Model 8620 woodstove\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003cli\u003eHardware kit: four feet with carriage leveling bolts, mounting bolts, flat washers, and lock washers; air control handle and nut; catalyst temperature indicator\u003c\/li\u003e\n\u003cli\u003eThree refractory floor stones, shipped in the firebox and assembled before final installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or requirement note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Heatshield\u003c\/td\u003e\n\u003ctd\u003e96-68200\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eClips onto the back of the stove to reduce rear clearances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Heatshield, Left or Right (single)\u003c\/td\u003e\n\u003ctd\u003e96-68205\u003c\/td\u003e\n\u003ctd\u003e$69\u003c\/td\u003e\n\u003ctd\u003eClips onto either side of the stove; one shield per side; install on both sides to reduce both side clearances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eConnects the air intake to a minimum 3\" outside air duct (ducting supplied by others); required for all mobile-home installations; in Canada, requires floor attachment and a damper allowing 100% closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eAdapter used with the Outside Air Starter when a 4\" outside air duct is needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Green Mountain 20 is covered by HearthStone's limited warranty to the original purchaser, including limited lifetime coverage (defined as 10 years) on stone, cast iron not listed elsewhere, and the wood clean-burning air-supply system; 5-year coverage on door handles and latches and on steel components and the firebox; 2-year coverage on refractory and vermiculite panels and baffles; and 1-year coverage on the enamel finish, accessories, glass, and other listed components. The catalytic combustor is warranted separately by its manufacturer, Applied Ceramics, with a two-year replacement warranty followed by a prorated schedule. Conditions, exclusions, and registration requirements apply; refer to the owner's manual for complete warranty terms.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthstone Quality Home Heating Products, Inc. of Morrisville, Vermont handcrafts soapstone and cast iron stoves that combine natural materials with advanced clean-burning combustion technology. The 2026 HearthStone catalog identifies the Green Mountain family of EPA certified room heaters as made in Vermont. Visit our showroom to see HearthStone quality in person and to discuss the right installation for your home.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53636749426964,"sku":"8620","price":2699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/0284__Hergom_GM20_001-02_1.webp?v=1786670175"},{"product_id":"hearthstone-stoves-bari-freestanding-wood-stove","title":"Hearthstone Stoves Bari Freestanding Wood Stove","description":"\u003ch2\u003eGerman-Crafted Rotating Wood Stove with TruHybrid™ Catalytic Combustion\u003c\/h2\u003e\n\u003cp\u003eThe Bari Model 8171 pairs HASE's German steel craftsmanship with HearthStone's TruHybrid™ combustion system, rotating a full 180° so the fire view can follow you around the room.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.94 g\/hr particulate emissions under the 2020 EPA particulate standard\u003c\/li\u003e\n\u003cli\u003e75.9% HHV weighted-average efficiency, measured across four burn-rate categories\u003c\/li\u003e\n\u003cli\u003eRotates a full 180° — up to 90° to either side — with a curved glass window presenting a fire view spanning up to approximately 225°\u003c\/li\u003e\n\u003cli\u003eHeats up to 1,400 sq. ft., depending on home insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eHeatLife™ of up to 14 hours, per current HearthStone consumer literature\u003c\/li\u003e\n\u003cli\u003eBuilt-in ash pan with a convenient ash-removal grate system\u003c\/li\u003e\n\u003cli\u003eEight factory finish configurations spanning steel, ceramic, and soapstone\u003c\/li\u003e\n\u003cli\u003eDesigned and manufactured in Germany by HASE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eGerman HASE Design\u003c\/h4\u003e\n\u003cp\u003eThe Bari is designed and manufactured exclusively in Germany by Hase Kaminofenbau GmbH of Trier. HASE precision-manufactures its steel, ceramic, and vermiculite components in-house, forming high-quality thick-gauge steel with modern processes to achieve a refined level of fit and finish. The result is a sleek cylindrical stove intended to complement contemporary living spaces.\u003c\/p\u003e\n\u003ch4\u003eTruHybrid™ Combustion\u003c\/h4\u003e\n\u003cp\u003eHearthStone's TruHybrid™ system combines primary and secondary combustion with tertiary combustion through a catalytic combustor. The catalyst becomes active at approximately 500°F, burning smoke and remaining particles that were not fully consumed in the firebox. A supplied catalyst thermometer indicates when the stove is in the active range, and a bypass control directs combustion products around the catalyst during startup and reloading. Under specific EPA test conditions, the Bari delivered heat at rates ranging from 14,065 to 26,036 BTU\/hr.\u003c\/p\u003e\n\u003ch4\u003e180° Rotating Fire View\u003c\/h4\u003e\n\u003cp\u003eThe Bari mechanically rotates a full 180° — up to 90° to either side of center — with 13 selectable positions controlled by a push-button release behind the lower control door. The stove can also be locked in a fixed position using the supplied rotation-lock procedure, which permits installation on a smaller hearth. The large curved glass window presents the fire across a viewing arc of up to approximately 225°.\u003c\/p\u003e\n\u003ch4\u003eNatural Convective Heat\u003c\/h4\u003e\n\u003cp\u003eHASE stoves are built in two layers. The inner steel body provides structure and controls combustion, while the outer finish panels create a convective air channel that circulates warm air through the room and reduces the outer surface temperature of the stove.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Bari Model 8171 is offered in eight current factory configurations. All configurations share the same firebox, combustion system, and performance specifications; pricing varies by finish. Visit our showroom to see finish samples and discuss availability.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish \/ Configuration\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharcoal Black Steel\u003c\/td\u003e\n\u003ctd\u003e8171-0115\u003c\/td\u003e\n\u003ctd\u003e$7,299\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharcoal Steel with Soapstone Top\u003c\/td\u003e\n\u003ctd\u003e8171-4115\u003c\/td\u003e\n\u003ctd\u003e$7,399\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLava Black Ceramic, Ringed Texture (Steel Body)\u003c\/td\u003e\n\u003ctd\u003e8171-5012\u003c\/td\u003e\n\u003ctd\u003e$8,599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeteorite Black Ceramic, Lined Texture (Steel Body)\u003c\/td\u003e\n\u003ctd\u003e8171-6212\u003c\/td\u003e\n\u003ctd\u003e$8,599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFjord Ceramic, Smooth (Steel Body)\u003c\/td\u003e\n\u003ctd\u003e8171-7212\u003c\/td\u003e\n\u003ctd\u003e$8,599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlabaster Ceramic, Smooth (Steel Body)\u003c\/td\u003e\n\u003ctd\u003e8171-7812\u003c\/td\u003e\n\u003ctd\u003e$8,599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWintersea Ceramic, Lined Texture (Steel Body)\u003c\/td\u003e\n\u003ctd\u003e8171-8212\u003c\/td\u003e\n\u003ctd\u003e$8,599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll Soapstone\u003c\/td\u003e\n\u003ctd\u003e8171-4112\u003c\/td\u003e\n\u003ctd\u003e$8,899\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion System\u003c\/td\u003e\n\u003ctd\u003eTruHybrid™ catalytic hybrid (primary, secondary, and catalytic tertiary combustion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHHV Efficiency\u003c\/td\u003e\n\u003ctd\u003e75.9% weighted average (EPA Method 28R, CSA B415-10 weighting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cordwood Output\u003c\/td\u003e\n\u003ctd\u003e26,000 BTU\/hr, per current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Tested Output\u003c\/td\u003e\n\u003ctd\u003e14,065 to 26,036 BTU\/hr under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Certified Emissions\u003c\/td\u003e\n\u003ctd\u003e0.94 g\/hr (2020 EPA particulate standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Area\u003c\/td\u003e\n\u003ctd\u003eUp to 1,400 sq. ft.; home factors can reduce heated area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox Capacity\u003c\/td\u003e\n\u003ctd\u003e1.25 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Log Length\u003c\/td\u003e\n\u003ctd\u003e17\" loaded vertically; 9\" loaded horizontally\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatLife™\u003c\/td\u003e\n\u003ctd\u003eUp to 14 hours, per current HearthStone consumer literature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e48.7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e18.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue Exit\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, top exit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney\u003c\/td\u003e\n\u003ctd\u003e6\" inside-diameter metal chimney; masonry chimney 6\" round or 8\" x 8\" square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney Height\u003c\/td\u003e\n\u003ctd\u003eMinimum 16 ft measured from the hearth pad; maximum recommended 30 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Draft\u003c\/td\u003e\n\u003ctd\u003e-0.06\" to -0.10\" WC; a stovepipe damper is required for draft above -0.10\" WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsh Pan\u003c\/td\u003e\n\u003ctd\u003eBuilt in, included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove Rotation\u003c\/td\u003e\n\u003ctd\u003e180° mechanical rotation, up to 90° to either side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire View\u003c\/td\u003e\n\u003ctd\u003eUp to approximately 225° through the curved glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, Steel Finish\u003c\/td\u003e\n\u003ctd\u003e310 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, Ceramic Finish\u003c\/td\u003e\n\u003ctd\u003e430 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, Soapstone Finish\u003c\/td\u003e\n\u003ctd\u003e485 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEPA 2020 certified; conforms to UL 1482-2022; certified to ULC S627:2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe Bari requires noncombustible ember protection only beneath and around the stove. Two installation modes are published: free to rotate, and locked in position using the supplied rotation-lock procedure. Minimum overall hearth dimensions differ by mode and country.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Mode\u003c\/th\u003e\n\u003cth\u003eUSA Minimum Hearth\u003c\/th\u003e\n\u003cth\u003eCanada Minimum Hearth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove free to rotate\u003c\/td\u003e\n\u003ctd\u003e51\" W x 39-1\/2\" D\u003c\/td\u003e\n\u003ctd\u003e55\" W x 43-1\/2\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove locked in position\u003c\/td\u003e\n\u003ctd\u003e29\" W x 35\" D\u003c\/td\u003e\n\u003ctd\u003e35\" W x 43-1\/2\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFront floor protection extends 16\" from the glass in the USA and 18\" from the glass in Canada. Installations in Canada require 18\" of floor protection at both the side and the front. Rear floor protection is required only if the stovepipe runs horizontally rearward above the top of the stove. Refer to the current owner's manual for the 8\" firebox-opening reference with the stove fully rotated and for complete hearth geometry.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Mode\u003c\/th\u003e\n\u003cth\u003eStove Body to Side Wall\u003c\/th\u003e\n\u003cth\u003eStove Body to Rear Wall\u003c\/th\u003e\n\u003cth\u003eStove Body to Corner Wall\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree to rotate, parallel (single or double wall connector)\u003c\/td\u003e\n\u003ctd\u003e38\"\u003c\/td\u003e\n\u003ctd\u003e13\"\u003c\/td\u003e\n\u003ctd\u003eNot published\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked in position, parallel (single or double wall connector)\u003c\/td\u003e\n\u003ctd\u003e13\"\u003c\/td\u003e\n\u003ctd\u003e11\"\u003c\/td\u003e\n\u003ctd\u003eNot published\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked in position, corner (single or double wall connector)\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe values above are stove-body clearances. The current owner's manual additionally publishes flue-centerline reference dimensions (its complete A through K clearance set) and NFPA-style combustible-wall pass-through construction methods; refer to the current manual for the full connector-centerline clearances and installation geometry. Clearances to combustible surfaces may be reduced only with an NFPA 211 approved wall-protection system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation restrictions:\u003c\/strong\u003e This unit has not been tested or recommended for alcove installation. The Bari is a freestanding room heater and is not to be installed in any factory-built fireplace. Keep furniture, drapes, firewood, and other combustibles at least 36\" from the stove.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlooring caution:\u003c\/strong\u003e Some luxury vinyl plank (LVP) and luxury vinyl tile (LVT) flooring can begin to warp at approximately 110°F. Consult the flooring manufacturer for maximum temperature recommendations; additional shielding may be required depending on the flooring used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMobile and manufactured homes:\u003c\/strong\u003e The Bari 8171 is approved for U.S. manufactured\/mobile-home installation under the listed requirements of the current owner's manual, including installation per 24 CFR Part 3280, permanent attachment to the floor structure, outside combustion air in all mobile-home installations with a 4\" fresh-air intake (using the 90-53308 adapter), an approved mobile-home chimney and connector system with spark arrester, and no installation in a sleeping room. The current manual calls for the Mobile Home Lock Down Kit 91-99400 for the required structural attachment; this kit does not appear on the current dealer pricing sheet, so verify current availability with our showroom or your installer. This unit is not approved for mobile-home installation to Canadian standards.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBari Model 8171 stove body in the selected purchased finish configuration\u003c\/li\u003e\n\u003cli\u003eBuilt-in ash pan and ash-removal grate system\u003c\/li\u003e\n\u003cli\u003e180° rotation mechanism with rotation-lock capability\u003c\/li\u003e\n\u003cli\u003eLower flue-collar section, factory attached\u003c\/li\u003e\n\u003cli\u003eUpper rotating flue-collar section with bearings, bearing carrier, and securing hardware, shipped in the firebox for assembly\u003c\/li\u003e\n\u003cli\u003eMounting feet and leveling hardware, shipped in the firebox\u003c\/li\u003e\n\u003cli\u003eCatalyst thermometer\u003c\/li\u003e\n\u003cli\u003eCatalytic combustor system\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCeramic finish panels ship in separate boxes and are installed during setup; they are part of the purchased configuration, not optional accessories. Soapstone panels are heavy and require careful two-person handling during assembly.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Adapter\u003c\/td\u003e\n\u003ctd\u003e91-53712\u003c\/td\u003e\n\u003ctd\u003e$259\u003c\/td\u003e\n\u003ctd\u003eConnects the air intake to a minimum 3\" duct supplied by others; the current manual requires attachment of the heater to the structure when the outside air kit is used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eUsed where the current manual requires or supports a 4\" fresh-air connection, including mobile-home installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual also calls for the Mobile Home Lock Down Kit 91-99400 for applicable structural attachment, including mobile-home installation and installations using the outside air kit. That kit is not present on the current dealer pricing sheet; verify current availability before installation.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Bari 8171 is covered by the HearthStone limited warranty to the original purchaser, with the term Limited Lifetime defined as 10 years from the beginning of warranty coverage. As published in the current owner's manual for wood appliances, coverage includes Limited Lifetime protection for stone and for cast iron not listed elsewhere along with the clean-burning air-supply system, 5-year coverage for door handles and latches and for steel components and the firebox, 2-year coverage for refractory and vermiculite panels and baffles, and 1-year coverage for enamel finish, accessories, glass, the ash grate, and components not listed elsewhere. The catalytic combustors (model ACI-6M2) are covered separately by their manufacturer, Applied Ceramics, under that company's own warranty terms included with the stove. Certain conditions and exclusions apply; refer to the current owner's manual for complete warranty terms and registration instructions.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone and HASE\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has specialized in premium wood and gas heating appliances for decades, and its TruHybrid™ combustion system pairs adjustable primary and secondary combustion with catalytic tertiary combustion for clean, efficient burns. The HASE Collection brings the work of Hase Kaminofenbau GmbH of Trier, Germany to the North American market: modern cylindrical stoves crafted with precision steel, designer ceramics, and natural soapstone. The Bari is displayed through authorized HearthStone dealers; visit our showroom to see it in person and discuss the right configuration for your home.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53651572883732,"sku":"8171","price":7299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Bari8171_Meeorite.webp?v=1786723955"},{"product_id":"hearthstone-stoves-bari-plus-freestanding-wood-stove","title":"Hearthstone Stoves Bari Plus Freestanding Wood Stove","description":"\u003ch2\u003eGerman-Engineered Rotating Wood Stove with TruHybrid™ Combustion and Included Heat-Retaining Thermal Brick\u003c\/h2\u003e\n\u003cp\u003eThe Bari Plus pairs HASE's rotating curved-glass design with TruHybrid™ catalytic combustion and included heat-retaining thermal bricks, extending gentle warmth well after the active fire declines.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTruHybrid™ combustion\u003c\/strong\u003e — primary and secondary combustion plus a tertiary catalytic stage, rated at 76% HHV efficiency and EPA certified at 0.94 g\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded heat-retaining thermal bricks\u003c\/strong\u003e line the firebox and fill the taller body, storing heat and releasing it gradually as the fire declines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 16 hours of HeatLife™\u003c\/strong\u003e from a single load of wood, depending on installation and operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e180° mechanical rotation\u003c\/strong\u003e — up to 90° to either side — with curved glass providing a fire view spanning up to approximately 225°.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats up to 1,400 sq. ft.\u003c\/strong\u003e, depending on home layout, climate, and installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in ash pan\u003c\/strong\u003e behind the control door for convenient ash removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned and manufactured in Germany\u003c\/strong\u003e by Hase Kaminofenbau GmbH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eGerman HASE Design\u003c\/h4\u003e\n\u003cp\u003eThe Bari Plus is designed and manufactured exclusively in Germany by Hase Kaminofenbau GmbH of Trier. Its slim cylindrical steel body, tall curved glass, and Charcoal Black Steel finish suit contemporary living spaces while keeping a compact 18.5\" footprint.\u003c\/p\u003e\n\u003ch4\u003eTruHybrid™ Combustion\u003c\/h4\u003e\n\u003cp\u003eHearthStone's TruHybrid™ system combines primary and secondary combustion with a tertiary combustion stage in a catalyst, burning remaining gases and particulates before they reach the chimney. The Bari Plus is rated at 76% HHV efficiency and is EPA certified at 0.94 g\/hr. A bypass is opened for startup and reloading, and a catalyst thermometer helps you monitor catalyst operation.\u003c\/p\u003e\n\u003ch4\u003eHeat-Retaining Thermal Brick\u003c\/h4\u003e\n\u003cp\u003eThe Bari Plus stands taller than the standard Bari, and that added height creates room for its included heat-retaining thermal brick system. Heat-storage bricks line the firebox and upper body, absorbing heat while the fire burns and releasing it gently as the fire declines — the manufacturer positions this stored-heat mass as the key to the Bari Plus's extended HeatLife™ of up to 16 hours.\u003c\/p\u003e\n\u003ch4\u003e180° Rotating Fire View\u003c\/h4\u003e\n\u003cp\u003eThe Bari Plus mechanically rotates through 180° — up to 90° to either side — so the fire can face different parts of the room, while its curved glass provides a fire view spanning up to approximately 225°. The rotation can also be locked, which reduces the required clearances and hearth size shown below.\u003c\/p\u003e\n\u003ch4\u003eNatural Convective Heat\u003c\/h4\u003e\n\u003cp\u003eThe Bari Plus heats through a combination of radiant heat from the glass and steel body and natural convective airflow around the cylinder. No blower is used or offered for this model, so it operates silently and without electricity.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finish and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe Bari Plus is currently offered in one configuration:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharcoal Black Steel\u003c\/td\u003e\n\u003ctd\u003e8172-0115\u003c\/td\u003e\n\u003ctd\u003e$7,599\u003c\/td\u003e\n\u003ctd\u003eWood-burning TruHybrid™ configuration; includes the heat-retaining thermal brick system and built-in ash pan.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBari Plus, Model 8172\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion System\u003c\/td\u003e\n\u003ctd\u003eTruHybrid™ catalytic hybrid (primary, secondary, and catalytic tertiary combustion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHHV Efficiency\u003c\/td\u003e\n\u003ctd\u003e76%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Certified Emissions\u003c\/td\u003e\n\u003ctd\u003e0.94 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cordwood Output\u003c\/td\u003e\n\u003ctd\u003e26,000 BTU\/hr, per current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Area\u003c\/td\u003e\n\u003ctd\u003eUp to 1,400 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox Capacity\u003c\/td\u003e\n\u003ctd\u003e1.25 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Log Length\u003c\/td\u003e\n\u003ctd\u003e17\" loaded vertically; 9\" loaded horizontally\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatLife™\u003c\/td\u003e\n\u003ctd\u003eUp to 16 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e54.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e18.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e425 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue Exit\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, top exit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney\u003c\/td\u003e\n\u003ctd\u003e6\" inside-diameter metal chimney, or masonry chimney with 6\" round or 8\" x 8\" square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Draft\u003c\/td\u003e\n\u003ctd\u003e-0.06\" to -0.10\" WC; stovepipe damper required above -0.10\" WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsh Pan\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove Rotation\u003c\/td\u003e\n\u003ctd\u003e180° mechanical rotation (up to 90° to either side), with rotation lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Viewing Arc\u003c\/td\u003e\n\u003ctd\u003eUp to approximately 225° through the curved glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat-Retaining Bricks\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eCharcoal Black Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003eGermany (Hase Kaminofenbau GmbH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eConforms to UL 1482-2022; certified to ULC S627:2023 (PFS Report F20-618)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe Bari Plus requires noncombustible ember protection only under and around the stove. The values below are stove-body clearances and minimum hearth sizes from the current owner's manual (R: 10\/23\/23); the manual separately publishes flue\/stove-centerline dimensions and combustible-wall pass-through constructions that must also be observed.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove free to rotate\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove free to rotate\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall\u003c\/td\u003e\n\u003ctd\u003e13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove free to rotate\u003c\/td\u003e\n\u003ctd\u003eMinimum hearth, USA (W x D)\u003c\/td\u003e\n\u003ctd\u003e51\" x 39-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove free to rotate\u003c\/td\u003e\n\u003ctd\u003eMinimum hearth, Canada (W x D)\u003c\/td\u003e\n\u003ctd\u003e55\" x 43-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove locked in position\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove locked in position\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall\u003c\/td\u003e\n\u003ctd\u003e11\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove locked in position, corner\u003c\/td\u003e\n\u003ctd\u003eStove body to either diagonal corner wall\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove locked in position\u003c\/td\u003e\n\u003ctd\u003eMinimum hearth, USA (W x D)\u003c\/td\u003e\n\u003ctd\u003e29\" x 35\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove locked in position\u003c\/td\u003e\n\u003ctd\u003eMinimum hearth, Canada (W x D)\u003c\/td\u003e\n\u003ctd\u003e35\" x 43-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFront floor protection must extend 16\" (USA) or 18\" (Canada) measured from the glass, with an 8\" reference from the firebox opening with the stove fully rotated; in Canada, 18\" of floor protection is required at the sides and front. Rear floor protection is required only if the stovepipe runs horizontally rearward above the stove top.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFloor protection is noncombustible ember protection only.\u003c\/li\u003e\n\u003cli\u003eThis unit has not been tested or recommended for alcove installation.\u003c\/li\u003e\n\u003cli\u003eThe Bari Plus is a freestanding room heater and is not to be installed in any factory-built fireplace.\u003c\/li\u003e\n\u003cli\u003eSome LVP\/LVT flooring can begin to warp at approximately 110 F; review the current manual's flooring caution when planning floor protection.\u003c\/li\u003e\n\u003cli\u003eU.S. manufactured\/mobile-home installation is permitted only under the exact requirements of the current manual, including permanent floor attachment, outside air in all mobile-home installations, an approved mobile-home chimney system, and no sleeping-room installation. This unit is not approved for mobile-home installation to Canadian standards.\u003c\/li\u003e\n\u003cli\u003eComplete installation must follow the current owner's manual and all applicable national and local requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBari Plus stove body in Charcoal Black Steel (stove subassembly 3917-2015)\u003c\/li\u003e\n\u003cli\u003eHeat-retaining thermal brick system, including the Bari Plus top heat-retaining stones\u003c\/li\u003e\n\u003cli\u003eBuilt-in ash pan and ash-removal system\u003c\/li\u003e\n\u003cli\u003e180° rotation mechanism with rotation lock\u003c\/li\u003e\n\u003cli\u003eTruHybrid™ catalytic combustor system with catalyst thermometer\u003c\/li\u003e\n\u003cli\u003eLower flue-collar section (factory attached) and upper rotating flue-collar section (assembled during setup)\u003c\/li\u003e\n\u003cli\u003eMounting feet with leveling hardware and the hardware kit shipped for assembly\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Adapter\u003c\/td\u003e\n\u003ctd\u003e91-53712\u003c\/td\u003e\n\u003ctd\u003e$259\u003c\/td\u003e\n\u003ctd\u003eFits Bari and Bari Plus; connects to a minimum 3\" outside-air duct supplied by others. The manual requires structural attachment when the outside-air system is used.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eUsed when adapting to the manual-supported or required 4\" fresh-air intake, including U.S. mobile-home installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual also requires Mobile Home Lock Down Kit 91-99400 for applicable structural attachment; it is not listed on the current dealer pricing sheet, so please verify current availability with us before planning an installation that requires it.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Bari Plus is covered by HearthStone's limited warranty as published in the current owner's manual, where Limited Lifetime is defined as ten years. In summary, the applicable schedule covers stone, cast iron components not listed elsewhere, and the clean-burning air-supply system for the Limited Lifetime period; door handles, latches, steel components, and the firebox for five years; refractory and vermiculite components for two years; and finish, glass, the ash grate, accessories, and components not otherwise listed for one year. The catalytic combustor (Applied Ceramics model ACI-6M2) is covered under a separate catalyst warranty. Conditions and exclusions apply; see the current warranty document for complete terms.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone and HASE\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built stoves prized for long-lasting, comfortable heat for more than four decades. The Bari and Bari Plus are contemporary stoves in the HASE family, designed and manufactured by Hase Kaminofenbau GmbH in Trier, Germany, and offered by HearthStone through authorized dealers.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone stoves in person, or contact us with questions about the Bari Plus, current pricing, and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53683640598804,"sku":"8172","price":7599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Bari-Plus-8172_Charcoal_220117.webp?v=1786763545"},{"product_id":"hearthstone-stoves-green-mountain-insert-70-wood-fireplace-insert","title":"Hearthstone Stoves Green Mountain Insert 70 Wood Fireplace Insert","description":"\u003ch2\u003eSteady Soapstone-Lined Wood Heat for Your Masonry Fireplace\u003c\/h2\u003e\n\u003cp\u003eThe Green Mountain Insert 70 (GMi70, Model 8450) is a non-catalytic wood fireplace insert with a flush cast iron design, soapstone-lined firebox, and factory-installed blower, in two finishes.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush cast iron design\u003c\/strong\u003e — the insert installs flush with the fireplace facing for a clean, built-in look, with an arched cast iron front in Black Matte or Brown Enamel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoapstone-lined firebox\u003c\/strong\u003e — a 2.4 cu. ft. firebox lined with natural soapstone accepts logs up to 20 inches and radiates steady warmth as the fire burns down.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-catalytic combustion\u003c\/strong\u003e — a single-lever primary air control adjusts the burn rate; there is no catalyst to monitor or replace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA 2020 certified using cordwood\u003c\/strong\u003e — certified at 2.3 g\/hr particulate emissions with a 72% (HHV) weighted average efficiency, per the current owner's manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum cordwood heat output of 44,500 BTU\/hr\u003c\/strong\u003e — with heating coverage of up to 2,000 square feet, depending on home layout, insulation, and operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded convection blower\u003c\/strong\u003e — the unit ships complete with a factory-installed blower with automatic heat-sensor operation and a manual mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatLife up to 8+ hours\u003c\/strong\u003e — per the current owner's manual, soapstone extends usable heat well after the active flames decline.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eFlush Cast Iron Design\u003c\/h4\u003e\n\u003cp\u003eThe GMi70 is designed to sit flush with the fireplace facing, framing the fire with an arched European cast iron front. An optional steel surround system trims the transition to the masonry opening, and the surround coverage measures approximately 45-3\/8 inches wide by 31-5\/8 inches tall per current HearthStone materials.\u003c\/p\u003e\n\u003ch4\u003eSoapstone-Lined Firebox\u003c\/h4\u003e\n\u003cp\u003eThe firebox is lined with natural soapstone panels over a steel firebox body. Soapstone absorbs heat during the burn and releases it gradually, moderating temperature swings and extending comfortable warmth. The overall firebox volume is 2.4 cu. ft., with an EPA loading volume of 1.95 cu. ft. and a maximum log length of up to 20 inches.\u003c\/p\u003e\n\u003ch4\u003eNon-Catalytic Combustion\u003c\/h4\u003e\n\u003cp\u003eA single primary air control lever under the ash lip regulates the burn rate from high to low. Secondary combustion air burns gases released by the wood, and an air-wash system helps keep the ceramic glass clear for viewing the fire. The glass is a clear ceramic material capable of operating at temperatures up to 2300°F.\u003c\/p\u003e\n\u003ch4\u003eIncluded Convection Blower\u003c\/h4\u003e\n\u003cp\u003eA blower is factory installed beneath the insert, behind the front casting. In the automatic position, a heat sensor starts the blower when the insert is hot and stops it as the insert cools; a manual position runs the blower at any time. The current dealer sheet confirms the unit ships complete with the blower.\u003c\/p\u003e\n\u003ch4\u003eFlexible Surround and Fireplace Fit\u003c\/h4\u003e\n\u003cp\u003eAn optional steel surround attaches behind the cast iron faceplate, an optional lower surround panel completes a four-sided surround for raised-hearth installations, and an optional surround extension allows the insert to project 2 or 4 inches into the room, reducing the required fireplace depth. These options let the GMi70 fit a range of masonry fireplace geometries; see the accessory table below.\u003c\/p\u003e\n\u003ch4\u003eFull-Length 6-Inch Liner Requirement\u003c\/h4\u003e\n\u003cp\u003eThe GMi70 must be installed with a continuous 6-inch listed stainless steel chimney liner extending from the insert to the top of the chimney, using liners listed to UL 1777, ULC S635, or CAN\/ULC S640. The manual describes three connection methods, including the recommended optional Liner Hook-Up Starter Collar, and recommends a sheet metal block-off plate to reduce cold-air backdrafts.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe GMi70 is a single base model available in two finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8450-0010\u003c\/td\u003e\n\u003ctd\u003e$4,599\u003c\/td\u003e\n\u003ctd\u003eShips complete with the factory-installed blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8450-0020\u003c\/td\u003e\n\u003ctd\u003e$5,099\u003c\/td\u003e\n\u003ctd\u003eShips complete with the factory-installed blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGreen Mountain Insert 70 (GMi70), Model 8450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eWood fireplace insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion system\u003c\/td\u003e\n\u003ctd\u003eNon-catalytic, single-lever primary air control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHHV efficiency\u003c\/td\u003e\n\u003ctd\u003e72% weighted average, per current owner's manual and EPA technical data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA particulate emissions\u003c\/td\u003e\n\u003ctd\u003e2.3 g\/hr, certified using cordwood, per current owner's manual and EPA certification data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum cordwood heat output\u003c\/td\u003e\n\u003ctd\u003e44,500 BTU\/hr, per current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA tested output\u003c\/td\u003e\n\u003ctd\u003e14,200–44,500 BTU\/hr under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating area\u003c\/td\u003e\n\u003ctd\u003eUp to 2,000 sq. ft., depending on home and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall firebox volume\u003c\/td\u003e\n\u003ctd\u003e2.4 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA loading volume\u003c\/td\u003e\n\u003ctd\u003e1.95 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003eUp to 20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatLife\u003c\/td\u003e\n\u003ctd\u003eUp to 8+ hours, per current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e33-1\/2\" W × 19-5\/8\" D × 25-3\/4\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e513 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eContinuous listed 6\" stainless steel chimney liner to the top of the chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMasonry chimney flue\u003c\/td\u003e\n\u003ctd\u003e6\" round, or 8\" × 8\" square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eIncluded, factory installed, automatic and manual modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eDry, seasoned natural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish options\u003c\/td\u003e\n\u003ctd\u003eBlack Matte or Brown Enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eLined masonry fireplace and masonry chimney only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFireplace Opening, Clearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe GMi70 and its stainless steel chimney liner are approved for installation only within a lined masonry chimney and masonry fireplace conforming to building codes for solid fuel. Do not remove bricks or mortar from the existing fireplace, do not connect to a chimney flue serving another appliance, and note that a positive flue connection to the clay tile is not approved. The GMi70 is not intended for installation in a bedroom.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Masonry Fireplace Opening\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e28-7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e23-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth, standard installation\u003c\/td\u003e\n\u003ctd\u003e19-5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth, with 2\" surround extension\u003c\/td\u003e\n\u003ctd\u003e17-5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth, with 4\" surround extension\u003c\/td\u003e\n\u003ctd\u003e15-5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhere a fresh air intake is needed, HearthStone suggests adding a minimum of 4 inches to the width of the minimum masonry opening. The optional surround extension permits the shallower 17-5\/8\" or 15-5\/8\" installation depths by projecting the insert 2 or 4 inches into the room when installed according to the current manual.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjacent combustible side wall\u003c\/td\u003e\n\u003ctd\u003e16\" from the insert body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible side surround or trim\u003c\/td\u003e\n\u003ctd\u003e9\" from the insert body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible top surround\u003c\/td\u003e\n\u003ctd\u003e27\" above the insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible mantel shelf\u003c\/td\u003e\n\u003ctd\u003e50\" from the bottom of the insert per current HearthStone materials; the manual states the corresponding minimum of 27\" above the insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel shelf depth\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum combustible side surround thickness\u003c\/td\u003e\n\u003ctd\u003e5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeiling\u003c\/td\u003e\n\u003ctd\u003e84\" above the hearth floor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearth and floor protection requirements depend on the height of the masonry hearth. If the hearth is at least 5 inches above the combustible floor, noncombustible floor protection with no specified R-value must extend at least 16 inches (USA) or 18 inches (Canada) in front of the insert. If the hearth elevation is less than 5 inches, the floor protector must have an R-value of at least 1.00 and extend at least 23 inches in front of the unit. In the USA, front and side protection is measured from the door opening; in Canada, the 8-inch side protection is measured from the side of the insert.\u003c\/p\u003e\n\u003cp\u003eThe standard installation leaves no projection of the convection air jacket in front of the fireplace opening; using the surround extension, the insert may project 2 or 4 inches into the room, and any additional floor protection is determined using the manual's calculation based on the existing hearth extension and the projection used. Note that some luxury vinyl plank and tile flooring may begin to warp around 110°F, so additional shielding may be necessary depending on the flooring manufacturer's limits. The current owner's manual governs every installation; review it with your installer and local building official for complete requirements.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGreen Mountain Insert 70 Model 8450 wood fireplace insert\u003c\/li\u003e\n\u003cli\u003eFactory-installed convection blower (the unit ships complete with the blower)\u003c\/li\u003e\n\u003cli\u003eTwo boxes of soapstone firebox lining\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003cli\u003eLeveling bolts (quantity 2)\u003c\/li\u003e\n\u003cli\u003eSoapstone spacers (quantity 2)\u003c\/li\u003e\n\u003cli\u003eMetal fireplace-installation label\u003c\/li\u003e\n\u003cli\u003eChimney-liner brackets (quantity 3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cp\u003eAll accessories are sold separately and installed per their instructions and the current manual.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel Surround\u003c\/td\u003e\n\u003ctd\u003e94-5950110\u003c\/td\u003e\n\u003ctd\u003e$259\u003c\/td\u003e\n\u003ctd\u003eThree-sided steel surround that attaches behind the cast iron faceplate to frame the fireplace opening.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Surround Panel\u003c\/td\u003e\n\u003ctd\u003e94-5950510\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eCompletes a four-sided surround for raised-hearth installations; used with the Steel Surround.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurround Extension\u003c\/td\u003e\n\u003ctd\u003e94-5950010\u003c\/td\u003e\n\u003ctd\u003e$149\u003c\/td\u003e\n\u003ctd\u003eAllows the insert to project 2\" or 4\" into the room, reducing the required fireplace depth per the current manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiner Hook-Up Starter Collar\u003c\/td\u003e\n\u003ctd\u003e94-67500\u003c\/td\u003e\n\u003ctd\u003e$160\u003c\/td\u003e\n\u003ctd\u003eHearthStone-recommended liner connection option for easier installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Screen\u003c\/td\u003e\n\u003ctd\u003e94-69500\u003c\/td\u003e\n\u003ctd\u003e$199\u003c\/td\u003e\n\u003ctd\u003ePermits open-door, direct-fire viewing; never leave the insert unattended while the fire screen is in use.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel Shield\u003c\/td\u003e\n\u003ctd\u003e94-79700\u003c\/td\u003e\n\u003ctd\u003e$239\u003c\/td\u003e\n\u003ctd\u003eShield for combustible mantels, approximately 48\" wide and trimmable; install per the current technical data sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Liner Adapter\u003c\/td\u003e\n\u003ctd\u003e5700-007\u003c\/td\u003e\n\u003ctd\u003e$409\u003c\/td\u003e\n\u003ctd\u003eOnly for installations where no other connection option is possible and the total fireplace and chimney height is at least 20 feet per the current manual; may cause smoke roll-out when the door is open.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Kit\u003c\/td\u003e\n\u003ctd\u003e94-53500\u003c\/td\u003e\n\u003ctd\u003e$129\u003c\/td\u003e\n\u003ctd\u003eConnects outside combustion air to the insert; recommended for airtight homes. Requires separately supplied 5\" insulated HVAC-type duct meeting the TDS requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe GMi70 is covered by HearthStone's limited warranty as published in the current owner's manual, where Limited Lifetime is defined as ten years. In summary, the applicable schedule covers external stone, cast iron components not listed elsewhere, and the clean-burning air-supply system for the Limited Lifetime period; door handles, latches, steel components, and the firebox for five years; appliance electrical components, refractory stone, vermiculite panels, and baffles for two years; and enamel finish, glass, accessories, and components not otherwise listed for one year. Warranty labor is covered in the first year through an authorized dealer when the appliance is dealer installed. Coverage extends to the original purchaser and is not transferable; conditions and exclusions apply. See the current written warranty for complete terms.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built stoves prized for long-lasting, comfortable heat for more than four decades. The Green Mountain Insert 70 brings HearthStone's signature soapstone lining to a flush-fitting wood fireplace insert offered through authorized dealers.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the GMi70, current pricing, and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53689714508052,"sku":"8450","price":4599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/GMi708450_NB-matteblack_200517.webp?v=1787103292"},{"product_id":"hearthstone-stoves-green-mountain-insert-90-wood-fireplace-insert","title":"Hearthstone Stoves Green Mountain Insert 90 Wood Fireplace Insert","description":"\u003ch2\u003eLarge-Capacity Soapstone-Lined Wood Heat for Your Existing Fireplace\u003c\/h2\u003e\n\u003cp\u003eThe Green Mountain Insert 90 (GMi90, Model 8460) is HearthStone's large non-catalytic wood fireplace insert with a flush cast iron front, 2.5 cu. ft. soapstone-lined firebox, and factory-installed blower.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge soapstone-lined firebox\u003c\/strong\u003e — a 2.5 cu. ft. firebox lined with natural soapstone accepts logs up to 20 inches and radiates steady warmth as the fire burns down.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush cast iron design\u003c\/strong\u003e — the insert sits flush with the fireplace facing for a built-in look, with a cast iron front in Black Matte or Brown Enamel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-catalytic secondary combustion\u003c\/strong\u003e — secondary air tubes and a baffle burn off gases released by the wood; a single-lever primary air control sets the burn rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA 2020 certified using cordwood\u003c\/strong\u003e — certified at 1.14 g\/hr particulate emissions with a 68% (HHV) weighted average efficiency, per the current owner's manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum cordwood heat output of 80,000 BTU\/hr\u003c\/strong\u003e — with heating coverage of up to 2,200 square feet, depending on home layout, insulation, and operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded convection blower\u003c\/strong\u003e — the unit ships complete with a factory-installed blower offering automatic heat-sensing operation, a manual mode, and variable speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatLife up to 9+ hours\u003c\/strong\u003e — per the current owner's manual, soapstone extends usable heat well after the active flames decline.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eLarge Soapstone-Lined Firebox\u003c\/h4\u003e\n\u003cp\u003eThe firebox is lined with natural soapstone panels over a steel firebox body. Soapstone absorbs heat during the burn and releases it gradually, moderating temperature swings and extending comfortable warmth. The firebox capacity is 2.5 cu. ft., with a maximum log length of up to 20 inches, and the manual notes the insert is intended to supplement rather than serve as the primary heat source for a home.\u003c\/p\u003e\n\u003ch4\u003eNon-Catalytic Secondary Combustion\u003c\/h4\u003e\n\u003cp\u003eA single primary air control lever under the ash lip regulates the burn rate from high to low (the control does not close completely). Secondary air tubes beneath the baffle at the top of the firebox supply air to burn gases released by the wood, and an air-wash system helps keep the ceramic glass clear for viewing the fire. The glass is a clear ceramic material capable of operating at temperatures up to 2300°F.\u003c\/p\u003e\n\u003ch4\u003eIncluded Convection Blower\u003c\/h4\u003e\n\u003cp\u003eA blower is factory installed behind the faceplate at the bottom of the insert to move room air through the convection air jacket. A rocker switch selects automatic or manual mode and a rheostat sets the blower speed. In automatic mode the blower starts when the insert is warm and stops as it cools; in manual mode it runs until switched off. A 90-degree connector is supplied for optional hardwiring through the rear of the insert. The current dealer sheet confirms the unit ships complete with the blower.\u003c\/p\u003e\n\u003ch4\u003eCast Iron Flush Design\u003c\/h4\u003e\n\u003cp\u003eThe GMi90 is designed to sit flush with the fireplace facing, framing the fire with a cast iron front and door. An optional three-piece steel surround attaches behind the cast iron faceplate to trim the transition to the fireplace opening; current HearthStone materials list surround coverage of approximately 50 inches wide by 34-1\/2 inches tall.\u003c\/p\u003e\n\u003ch4\u003eFlexible Fireplace Fit\u003c\/h4\u003e\n\u003cp\u003eThe GMi90 is designed for installation in a compliant masonry fireplace and chimney, or in a qualifying listed factory-built fireplace system that meets every condition in the current Model 8460 manual, including listing to UL 127 or ULC S610 and a full-height listed chimney liner. An optional surround extension lets the insert project farther into the room, reducing the minimum fireplace depth per the manual. The GMi90 is not approved for mobile home installation and is not a freestanding stove.\u003c\/p\u003e\n\u003ch4\u003eFull-Length 6-Inch Liner Requirement\u003c\/h4\u003e\n\u003cp\u003eThe GMi90 must be connected to a listed 6-inch stainless steel flexible connector and a continuous listed 6-inch stainless steel liner extending from the insert to the top of the chimney, using liners meeting UL 1777, ULC S635, or ULC S640 as applicable. A sealed block-off plate or noncombustible plug is required at the existing fireplace damper area, the fireplace damper must be removed or locked open, and the insert must never share a flue with another appliance or connect to any air-distribution duct. The manual requires a draft between 0.06 and 0.10 inches of water column, with a stovepipe damper installed where draft exceeds 0.10 inches.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe GMi90 is a single base model available in two finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8460-0010\u003c\/td\u003e\n\u003ctd\u003e$5,399\u003c\/td\u003e\n\u003ctd\u003eShips complete with the factory-installed blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8460-0020\u003c\/td\u003e\n\u003ctd\u003e$5,849\u003c\/td\u003e\n\u003ctd\u003eShips complete with the factory-installed blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGreen Mountain Insert 90 (GMi90), Model 8460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eWood fireplace insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion system\u003c\/td\u003e\n\u003ctd\u003eNon-catalytic secondary combustion (secondary air tubes and baffle), single-lever primary air control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA certification\u003c\/td\u003e\n\u003ctd\u003eEPA 2020 particulate standard, certified using cordwood; tested to EPA Alt 125 where applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHHV efficiency\u003c\/td\u003e\n\u003ctd\u003e68% weighted average, per current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA particulate emissions\u003c\/td\u003e\n\u003ctd\u003e1.14 g\/hr, per current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum cordwood heat output\u003c\/td\u003e\n\u003ctd\u003e80,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA tested output\u003c\/td\u003e\n\u003ctd\u003e14,200–48,200 BTU\/hr under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating area\u003c\/td\u003e\n\u003ctd\u003eUp to 2,200 sq. ft., depending on home and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003eUp to 20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatLife\u003c\/td\u003e\n\u003ctd\u003eUp to 9+ hours, per current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e38-1\/2\" W × 24-7\/8\" D × 28-3\/4\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e440 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eContinuous listed 6\" stainless steel chimney liner to the top of the chimney; existing 8\" flue may be used with an appropriate reducer per the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMasonry chimney flue\u003c\/td\u003e\n\u003ctd\u003e6\" round, or 8\" × 8\" square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired draft\u003c\/td\u003e\n\u003ctd\u003e0.06\"–0.10\" WC; stovepipe damper required above 0.10\" WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended chimney height\u003c\/td\u003e\n\u003ctd\u003e10 ft minimum, 30 ft maximum, provided adequate draft is achieved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eIncluded, factory installed, automatic and manual modes with variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside air\u003c\/td\u003e\n\u003ctd\u003eOptional Outside Air Kit 94-53500; minimum 3\" duct supplied by others per the current manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eDry, seasoned natural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish options\u003c\/td\u003e\n\u003ctd\u003eBlack Matte or Brown Enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eCompliant masonry fireplace and chimney, or qualifying listed factory-built fireplace system, per current manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile home\u003c\/td\u003e\n\u003ctd\u003eNot approved for mobile home installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety listing\u003c\/td\u003e\n\u003ctd\u003eUL 1482 and UL 737 (USA); ULC S628 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFireplace Opening, Clearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe GMi90 must be installed with a continuous 6-inch listed stainless steel chimney liner to the top of the chimney. Masonry fireplaces must have a code-approved lined chimney, and factory-built fireplaces must be listed to UL 127 or ULC S610, include a full-height listed liner, keep room air out of the chimney cavity, retain unblocked cooling-air and circulating chambers, remain unaltered except as the manual permits, and carry the permanent warning label supplied with the GMi90. Do not connect the insert to a chimney flue serving another appliance. The GMi90 is not approved for mobile home installation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Fireplace Opening\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e31-3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e27-1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth, standard installation\u003c\/td\u003e\n\u003ctd\u003e22-1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth, with surround extension (projection configurations)\u003c\/td\u003e\n\u003ctd\u003e20-1\/8\" or 18-1\/8\", depending on the projection configuration used per the current manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhere a fresh-air intake is required, HearthStone recommends adding at least 4 inches to the minimum fireplace-opening width. The optional surround extension permits the shallower installation depths by allowing the insert to project into the room when installed according to the current manual.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjacent combustible side wall\u003c\/td\u003e\n\u003ctd\u003e19\" from the insert body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible side trim or surround\u003c\/td\u003e\n\u003ctd\u003e9-1\/2\" from the insert body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible top surround or trim\u003c\/td\u003e\n\u003ctd\u003e12\" above the insert, per the manual's upper-reference clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible mantel\u003c\/td\u003e\n\u003ctd\u003e40-3\/4\" minimum from the bottom of the insert per current HearthStone materials; this corresponds to the current manual's 12\" clearance above the applicable upper insert reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum combustible mantel depth\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum combustible side trim thickness\u003c\/td\u003e\n\u003ctd\u003e5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeiling\u003c\/td\u003e\n\u003ctd\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth and Floor Protection\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum floor protection, USA\u003c\/td\u003e\n\u003ctd\u003e41-1\/2\" wide × 16\" in front, measured from the door opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum floor protection, Canada\u003c\/td\u003e\n\u003ctd\u003e48\" wide × 18\" in front, measured from the door opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulated hearth pad\u003c\/td\u003e\n\u003ctd\u003eNot required; there is no R-value requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eNoncombustible ember protection such as a continuous layer of tile, brick, slate, glass, or other noncombustible facing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual does not require an insulated hearth pad for the GMi90; combustible flooring in front of the insert must be covered with noncombustible material to the dimensions above. For raised and non-raised installations, and where the insert projects into the room, any additional floor protection is determined using the manual's floor-protection figures and the projection dimensions of the installation. Some luxury vinyl plank and tile flooring may begin to warp at approximately 110°F; consult the flooring manufacturer for maximum temperature limits, as additional shielding may be needed depending on the flooring used. The current owner's manual governs every installation; review it with your installer and local building official for complete requirements.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGreen Mountain Insert 90 Model 8460 wood fireplace insert\u003c\/li\u003e\n\u003cli\u003eFactory-installed convection blower (the unit ships complete with the blower)\u003c\/li\u003e\n\u003cli\u003eThree boxes of refractory stone firebox lining (two rear, two side-rear, and two side-front stones)\u003c\/li\u003e\n\u003cli\u003eSide stone retainer brackets\u003c\/li\u003e\n\u003cli\u003eLeg leveling bolts (quantity 2)\u003c\/li\u003e\n\u003cli\u003e90-degree Romex connector for optional blower hardwiring\u003c\/li\u003e\n\u003cli\u003eRear valence cover bracket (installed or packed with the insert)\u003c\/li\u003e\n\u003cli\u003eSafety label (attached to the insert)\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cp\u003eAll accessories are sold separately and installed per their instructions and the current manual.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel Surround\u003c\/td\u003e\n\u003ctd\u003e94-5960010\u003c\/td\u003e\n\u003ctd\u003e$149\u003c\/td\u003e\n\u003ctd\u003eThree-piece steel surround that attaches behind the cast iron faceplate to frame the fireplace opening.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurround Extension\u003c\/td\u003e\n\u003ctd\u003e94-5960110\u003c\/td\u003e\n\u003ctd\u003e$219\u003c\/td\u003e\n\u003ctd\u003eInstalled between the cast iron faceplate and the steel surround; allows the insert to project farther into the room, reducing the minimum required fireplace depth per the current manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Screen Insert\u003c\/td\u003e\n\u003ctd\u003e94-69110\u003c\/td\u003e\n\u003ctd\u003e$349\u003c\/td\u003e\n\u003ctd\u003ePermits attended open-door fire viewing under the manufacturer's instructions; never leave the insert unattended while the fire screen is in use.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiner Hook-Up Starter Collar\u003c\/td\u003e\n\u003ctd\u003e94-67500\u003c\/td\u003e\n\u003ctd\u003e$160\u003c\/td\u003e\n\u003ctd\u003eConnects to the chimney liner before the insert is placed, then secures to the insert once it is in the fireplace.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel Shield\u003c\/td\u003e\n\u003ctd\u003e94-79700\u003c\/td\u003e\n\u003ctd\u003e$239\u003c\/td\u003e\n\u003ctd\u003eShield for combustible mantels, approximately 48\" wide and trimmable; install per the current instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Liner Adapter\u003c\/td\u003e\n\u003ctd\u003e5700-007\u003c\/td\u003e\n\u003ctd\u003e$409\u003c\/td\u003e\n\u003ctd\u003eUsed where installation geometry requires offsetting the liner connection; installation must follow the current GMi90 manual and current accessory instructions, with proper draft verified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Kit\u003c\/td\u003e\n\u003ctd\u003e94-53500\u003c\/td\u003e\n\u003ctd\u003e$129\u003c\/td\u003e\n\u003ctd\u003eConnects outside combustion air to the insert where infiltration air is inadequate; requires a separately supplied duct of at least 3\" diameter per the current Model 8460 manual. In Canada the insert must be secured to the floor with the supplied shipping clips when outside air is used.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eAdapter referenced by the current manual for installations using a 4\" outside air duct.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe GMi90 is covered by HearthStone's limited warranty as published in the current owner's manual, where Limited Lifetime is defined as ten years. In summary, the applicable schedule covers stone, cast iron components not listed elsewhere, and the clean-burning air-supply system for the Limited Lifetime period; door handles, latches, steel components, and the firebox for five years; appliance electrical components, refractory, vermiculite panels, and baffles for two years; and enamel finish, glass, accessories, and components not otherwise listed for one year. Warranty labor is covered in the first year through an authorized dealer when the appliance is dealer installed, and parts shipping is covered for the first 90 days under the written terms. Coverage extends to the original purchaser and is not transferable; wear parts and conditions and exclusions apply. See the current written warranty for complete terms.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built stoves prized for long-lasting, comfortable heat for more than four decades. The Green Mountain Insert 90 brings HearthStone's signature soapstone lining to a large flush-fitting wood fireplace insert offered through authorized dealers.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the GMi90, current pricing, and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53700379214100,"sku":"8460","price":5399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/GMI90-8460_210426.webp?v=1787278349"},{"product_id":"hearthstone-stoves-wfp-100-zero-clearance-wood-fireplace","title":"Hearthstone Stoves WFP-100 Zero Clearance Wood Fireplace","description":"\u003ch2\u003eBuilt-In Wood Heat on a Grand Scale from HearthStone's Largest Zero-Clearance Fireplace\u003c\/h2\u003e\n\u003cp\u003eThe WFP-100 (Model 8420) is HearthStone's largest EPA-certified zero-clearance wood fireplace, combining a 4.28 cu. ft. firebox, double cast-iron-framed glass doors, and an included convection blower.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge 4.28 cu. ft. firebox\u003c\/strong\u003e — accepts logs up to 25\" loaded east-west, with a 16\" north-south log length recommended by the current owner's manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum heat output up to 95,000 BTU\/hr\u003c\/strong\u003e — per current HearthStone specifications, with a recommended heating area of 1,000 to 2,800 sq. ft. depending on home layout, insulation, and operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA 2020 certified using cordwood\u003c\/strong\u003e — certified at 1.6 g\/hr particulate emissions, with an EPA tested heat output of 16,610–43,021 BTU\/hr under specific test conditions and a 64% (HHV) average overall efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-catalytic double combustion\u003c\/strong\u003e — a self-regulating system pairing a primary combustion control with four secondary-air tubes beneath a C-Cast baffle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum burn time up to 10 hours\u003c\/strong\u003e — per the current owner's manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded convection blower\u003c\/strong\u003e — rated up to 176 CFM to move warmed air into the living space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble ceramic-glass doors with cast-iron frames\u003c\/strong\u003e — a wide view of the fire framed by a textured cast-iron facade in Matte Black or Brown Enamel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance construction\u003c\/strong\u003e — engineered for framed new-construction and remodeling installations with a dedicated 8\" chimney system; the specified clearances, framing, facing, and hearth protection in the current manual still apply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eLarge Zero-Clearance Fireplace Design\u003c\/h4\u003e\n\u003cp\u003eThe WFP-100 is a built-in wood-burning fireplace designed to be framed into new construction or a remodel, without the mass and footprint of a site-built masonry fireplace. The fireplace enclosure permits 0\" clearance at the back, sides, and floor under the fireplace, while every other published clearance, framing, facing, and hearth requirement in the current Model 8420 manual applies. The decorative cast-iron facade measures 50-3\/4\" wide, with an arched face of approximately 45-1\/4\" wide by 41-1\/2\" tall per the current HearthStone catalog, and a straight-wall framing depth reference of 26-7\/8\".\u003c\/p\u003e\n\u003ch4\u003e4.28 Cu. Ft. Firebox\u003c\/h4\u003e\n\u003cp\u003eThe 4.28 cu. ft. firebox burns dry, seasoned cordwood and accepts logs up to 25\" long loaded east-west. The current owner's manual recommends 16\" logs loaded north-south for everyday burning. Published maximum burn time is up to 10 hours, depending on wood, draft, and operating conditions.\u003c\/p\u003e\n\u003ch4\u003eNon-Catalytic Double Combustion\u003c\/h4\u003e\n\u003cp\u003eA self-regulating double-combustion system burns the wood and then the gases it releases. A primary combustion control regulates the burn, while four secondary-air tubes beneath the C-Cast baffle supply air to complete combustion before the exhaust enters the chimney. The system is certified to the EPA 2020 particulate standard using cordwood at 1.6 g\/hr, with a 64% (HHV) average overall efficiency per current HearthStone specifications (63.9% as printed in the current manual) and an optimum efficiency of 69.7% (LHV) at a specific burn rate.\u003c\/p\u003e\n\u003ch4\u003eIncluded Convection Blower\u003c\/h4\u003e\n\u003cp\u003eA convection blower rated up to 176 CFM is included with the fireplace, drawing room air around the firebox and returning warmed air to the living space.\u003c\/p\u003e\n\u003ch4\u003eDouble Cast-Iron-Framed Glass Doors\u003c\/h4\u003e\n\u003cp\u003eTwo ceramic-glass doors with cast-iron frames give the WFP-100 the wide, open sightline of a traditional hearth. The door opening measures approximately 33\" wide by 12-3\/4\" tall per the current manual's dimensional drawing, behind a hand-textured cast-iron facade.\u003c\/p\u003e\n\u003ch4\u003eRefractory Ceramic Interior\u003c\/h4\u003e\n\u003cp\u003eThe firebox is lined with molded refractory ceramic panels in a stacked-stone texture, reflecting heat back into the fire for cleaner combustion and giving the firebox a finished masonry appearance.\u003c\/p\u003e\n\u003ch4\u003eFlexible Heat Distribution Options\u003c\/h4\u003e\n\u003cp\u003eBeyond the included blower, the optional Forced Hot Air Kit (94-57200) can move heat to another room up to 50 ft away, and the optional Hot Air Circulation Kit (94-99200) adds passive convection vents. Fresh-air connector components — a 5\" adapter, an air-inlet block-off plate, and four screws — are included with the fireplace for installations that connect outside combustion air.\u003c\/p\u003e\n\u003ch4\u003eDedicated 8-Inch Chimney System\u003c\/h4\u003e\n\u003cp\u003eThe WFP-100 uses a dedicated 8\" chimney system listed to UL 103 HT (2100°F) or CAN\/ULC S629, beginning with the appropriate listed 8\" anchor plate. The minimum straight system height is 15 ft from the bottom of the unit to the chimney cap, and the fireplace must never share a flue with any other appliance.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe WFP-100 is a single base model available in two finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatte Black\u003c\/td\u003e\n\u003ctd\u003e8420-0010\u003c\/td\u003e\n\u003ctd\u003e$9,149\u003c\/td\u003e\n\u003ctd\u003eShips with the included convection blower and fresh-air connector components.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8420-0020\u003c\/td\u003e\n\u003ctd\u003e$9,699\u003c\/td\u003e\n\u003ctd\u003eShips with the included convection blower and fresh-air connector components.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWFP-100, Model 8420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eZero-clearance wood-burning fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eDry, seasoned cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion system\u003c\/td\u003e\n\u003ctd\u003eNon-catalytic primary and secondary (double) combustion with four secondary-air tubes and C-Cast baffle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output\u003c\/td\u003e\n\u003ctd\u003eUp to 95,000 BTU\/hr, per current HearthStone specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA tested heat output\u003c\/td\u003e\n\u003ctd\u003e16,610–43,021 BTU\/hr under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage overall efficiency\u003c\/td\u003e\n\u003ctd\u003e64% (HHV) per current HearthStone specifications (63.9% as printed in the current manual); 68.4% (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum efficiency\u003c\/td\u003e\n\u003ctd\u003e69.7% (LHV) at a specific burn rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA particulate emissions\u003c\/td\u003e\n\u003ctd\u003e1.6 g\/hr, certified using cordwood (EPA \/ ASTM WK47329)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended heating area\u003c\/td\u003e\n\u003ctd\u003e1,000 to 2,800 sq. ft., depending on home and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e4.28 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e25\", east-west\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended log length\u003c\/td\u003e\n\u003ctd\u003e16\", north-south, per the owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum burn time\u003c\/td\u003e\n\u003ctd\u003eUp to 10 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet\u003c\/td\u003e\n\u003ctd\u003e8\" diameter, top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney\u003c\/td\u003e\n\u003ctd\u003e8\" diameter, listed to UL 103 HT (2100°F) or CAN\/ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaffle\u003c\/td\u003e\n\u003ctd\u003eC-Cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoors\u003c\/td\u003e\n\u003ctd\u003eDouble ceramic-glass doors with cast-iron frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFacade\u003c\/td\u003e\n\u003ctd\u003eTextured cast iron, 50-3\/4\" decorative facade width; arched face approximately 45-1\/4\" W × 41-1\/2\" H per current catalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eIncluded, rated up to 176 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance weight\u003c\/td\u003e\n\u003ctd\u003e665 lb, including refractory slabs and faceplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e545 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove installation\u003c\/td\u003e\n\u003ctd\u003eNot approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile \/ manufactured home installation\u003c\/td\u003e\n\u003ctd\u003eNot approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety listing\u003c\/td\u003e\n\u003ctd\u003eUL 127 (USA); ULC-S610 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish options\u003c\/td\u003e\n\u003ctd\u003eMatte Black or Brown Enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation, Clearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003e\"Zero clearance\" describes this class of built-in fireplace, not an absence of requirements. The current Model 8420 manual permits 0\" enclosure clearance at the back, sides, and floor under the fireplace, and at the same time requires the combustible clearances, noncombustible facing, hearth protection, and chimney clearance below. The current owner's manual and its drawings govern every installation; review them with your installer and local building official.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible side trim, from the door opening\u003c\/td\u003e\n\u003ctd\u003e8\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjacent combustible side wall, from the door opening\u003c\/td\u003e\n\u003ctd\u003e24\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible side trim or mantel projection\u003c\/td\u003e\n\u003ctd\u003e6\" maximum, as shown by the manual's clearance figure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible wall in front of the fireplace\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeiling\u003c\/td\u003e\n\u003ctd\u003e84\", measured from the base of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace enclosure, back\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace enclosure, sides\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor under the fireplace\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney, to combustibles\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual publishes five hearth and floor-protection configurations. All five are reproduced below; do not rely on a single simplified R-value statement.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth Configuration\u003c\/th\u003e\n\u003cth\u003eRequired R-value\u003c\/th\u003e\n\u003cth\u003eMinimum front protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 1 — installed directly on the floor\u003c\/td\u003e\n\u003ctd\u003eR 2.00\u003c\/td\u003e\n\u003ctd\u003e32\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 2 — raised less than 8\" from the floor\u003c\/td\u003e\n\u003ctd\u003eR 2.00\u003c\/td\u003e\n\u003ctd\u003e32\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 3 — raised more than 8\" from the floor\u003c\/td\u003e\n\u003ctd\u003eR 2.00\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 4 — raised between 8\" and 12\", per the detailed option figure\u003c\/td\u003e\n\u003ctd\u003eR 1.00\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 5 — raised more than 12\", per the detailed Option 5 heading\u003c\/td\u003e\n\u003ctd\u003eNo R-value requirement\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn every configuration, the hearth protection must be at least 49\" wide in total, extending at least 8\" beyond each side of the door opening, with a 2\" sheet-metal joint-protection detail where the manual specifies it. The current Model 8420 manual is internally inconsistent at the 8\" and 12\" height boundaries. Its later minimum-hearth summary describes Option 4 as more than 8\" but less than 12\" and Option 5 as 12\" or more, while the detailed option headings use different boundary wording, and the Option 3 and Option 4 height descriptions overlap above 8\". Do not infer the required hearth construction for an installation exactly 8\" or exactly 12\" high from this summary alone; confirm the applicable configuration using the current Model 8420 manual, HearthStone and installer guidance, local code, and the authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003eFraming and facing requirements include the following. These reference values do not replace the manual's complete installation drawings, and allowances may need to increase for the fresh-air kit, the forced-air kit, or the finish materials used.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming and Facing Reference\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStraight-wall framing reference\u003c\/td\u003e\n\u003ctd\u003e50-3\/4\" wide × 26-7\/8\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming material, sides and rear\u003c\/td\u003e\n\u003ctd\u003e2\" × 3\" or heavier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectly above the fireplace\u003c\/td\u003e\n\u003ctd\u003eNo combustible framing; the zone must remain empty for 84\" from the base of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFresh-air framing allowance\u003c\/td\u003e\n\u003ctd\u003e12\" minimum on the applicable side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForced-air-kit framing allowance\u003c\/td\u003e\n\u003ctd\u003e18\" minimum on the applicable side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorner framing references\u003c\/td\u003e\n\u003ctd\u003e67-5\/8\" and 95-11\/16\", as shown by the manufacturer drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFacing\u003c\/td\u003e\n\u003ctd\u003eMaterials directly in front of the fireplace must be noncombustible; the faceplate must remain removable after the finish is installed; facing interface gap minimum 1\/2\", maximum 1-3\/8\", as shown in the manual detail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoncombustible shelf\u003c\/td\u003e\n\u003ctd\u003ePermitted only at 52\" or more from the base of the fireplace; the manual identifies this shelf as noncombustible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe chimney is a dedicated listed 8\" system (UL 103 HT or CAN\/ULC S629) beginning with the appropriate listed 8\" anchor plate and components. The minimum system height for a straight installation is 15 ft from the bottom of the unit to the chimney cap, and an installation at the minimum height requires optimal conditions. Where offsets are used, the manual calls for a minimum 18\" rise before the first offset, a 15 ft minimum system height with two elbows, and a 17 ft minimum with four elbows. The chimney must terminate at least 3 ft above its point of contact with the roof and at least 2 ft higher than any wall, roof, or building within 10 ft, must be braced if it extends more than 5 ft above the roof, and must maintain 2\" clearance to combustibles. A chimney venting this fireplace must not vent any other appliance. For certain masonry applications, the current manual provides approved chimney and liner connection methods; the fireplace is not approved for a so-called positive flue connection to the clay tile of a masonry chimney. Alcove and mobile\/manufactured-home installations are not approved.\u003c\/p\u003e\n\u003cp\u003eA supply of outside combustion air is strongly recommended and is required by some jurisdictions and codes. The fresh-air connector components included with the fireplace are a 5\" adapter, an air-inlet block-off plate, and four screws; the 5\" insulated flexible duct, outside wall termination, and two adjustable clamps are not included. The intake connects at the right side or right-side\/bottom location per the manual. Runs under 20 ft use 5\" duct; runs over 20 ft, or with more than two deviations, use 6\" duct, with a maximum duct length of 30 ft. The outside termination must not be located more than 50% of the total chimney height, more than 10 ft above the fireplace base, or more than 3 ft below it. Combustion air must come from outside the home — never from an attic, basement, or garage.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConvection blower, rated up to 176 CFM (included)\u003c\/li\u003e\n\u003cli\u003eFresh-air connector components: 5\" adapter, air-inlet block-off plate, and four screws (included with the fireplace)\u003c\/li\u003e\n\u003cli\u003eRefractory ceramic firebox interior (integral to the appliance)\u003c\/li\u003e\n\u003cli\u003eDouble ceramic-glass doors with cast-iron frames (integral to the appliance design)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 5\" insulated flexible fresh-air duct, outside wall termination, and adjustable clamps are not included and are supplied by the installer when outside air is connected.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cp\u003eAccessories are sold separately and installed per their instructions and the current Model 8420 manual.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForced Hot Air \/ Forced Air Convection Kit\u003c\/td\u003e\n\u003ctd\u003e94-57200\u003c\/td\u003e\n\u003ctd\u003e$949\u003c\/td\u003e\n\u003ctd\u003eConnects to either side of the WFP-100 and can distribute heat to another room up to 50 ft away when installed to the manufacturer's instructions; insulated flexible HVAC pipe is not included. The termination grille requires 1\" clearance to combustibles, and in Canada the termination grille must be at least 59\" above the floor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Air Circulation \/ Gravity Convection Kit\u003c\/td\u003e\n\u003ctd\u003e94-99200\u003c\/td\u003e\n\u003ctd\u003e$369\u003c\/td\u003e\n\u003ctd\u003eAdds wall-cavity vents that circulate warm air by natural convection; per the current HearthStone description, the vents are not directly ducted to the fireplace.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe WFP-100 is covered by the limited warranty published in the current Model 8420 owner's manual. In summary: combustion chamber welds, castings, the convector air-mate, and ceramic glass against thermal breakage carry lifetime parts coverage with four years of labor; plating carries lifetime parts coverage for manufacturing defects, subject to the written terms; stainless-steel firebox components, surrounds and heat shields, the C-Cast baffle, and secondary air tubes carry five years parts and three years labor; carbon-steel firebox components, glass retainers, and the handle assembly carry three years parts and two years labor; blowers, heat sensors, switches, rheostats, wiring, and controls carry two years parts and one year labor; and paint peeling, gaskets, insulation, and firebrick carry one year parts coverage. Lifetime coverage is subject to a one-time replacement limit. Coverage applies to the original consumer purchaser of a brand-new product in normal residential use, is not transferable, and requires authorized, qualified installation. See the current written warranty for complete terms.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built stoves prized for long-lasting, comfortable heat for more than four decades. The WFP-100 pairs HearthStone's textured European cast iron with the company's largest zero-clearance wood fireplace, offered through authorized dealers.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the WFP-100, current pricing, and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53705332490516,"sku":"8420","price":9149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/WFP1008420_190306.webp?v=1787362773"},{"product_id":"hearthstone-stoves-wfp-75-zero-clearance-wood-fireplace","title":"Hearthstone Stoves WFP-75 Zero Clearance Wood Fireplace","description":"\u003ch2\u003eBuilt-In Wood Heat and Classic Cast-Iron Character in a Zero-Clearance Fireplace\u003c\/h2\u003e\n\u003cp\u003eThe WFP-75 (Model 8411) is an EPA-certified zero-clearance wood fireplace pairing a 2.5 cu. ft. firebox, a single cast-iron-framed glass door, and an included convection blower.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 cu. ft. firebox\u003c\/strong\u003e — accepts logs up to 20\" loaded east-west, with a 16\" north-south log length recommended by the current owner's manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum heat output up to 80,000 BTU\/hr\u003c\/strong\u003e — with dry cordwood, per the current owner's manual, and a recommended heating area of 750 to 2,200 sq. ft. depending on home layout, insulation, and operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA certified using cordwood\u003c\/strong\u003e — certified at 1.14 g\/hr average particulate emissions, with a tested overall heat output of 14,200–48,200 BTU\/hr under specific test conditions and a 68% (HHV) average overall efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-catalytic double combustion\u003c\/strong\u003e — a primary and secondary combustion system with secondary-air tubes beneath a C-Cast baffle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum burn time up to 9 hours\u003c\/strong\u003e — per the current owner's manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded convection blower\u003c\/strong\u003e — rated up to 176 CFM to move warmed air into the living space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle ceramic-glass door with cast-iron frame\u003c\/strong\u003e — a wide view of the fire behind a chiseled-texture cast-iron facade in Matte Black or Brown Enamel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance construction\u003c\/strong\u003e — engineered for framed new-construction and remodeling installations with a dedicated 6\" chimney system; the specified clearances, framing, facing, and hearth protection in the current manual still apply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eZero-Clearance Built-In Design\u003c\/h4\u003e\n\u003cp\u003eThe WFP-75 is a built-in wood-burning fireplace designed to be framed into new construction or a remodel, without the mass and footprint of a site-built masonry fireplace. The fireplace enclosure permits 0\" clearance at the back, sides, and floor under the fireplace, while every other published clearance, framing, facing, and hearth requirement in the current Model 8411 manual applies. The arched face measures approximately 35-1\/2\" wide by 37\" tall per the current HearthStone catalog, with a door opening of approximately 24-1\/2\" wide by 12-3\/4\" tall per the current manual's dimensional drawing.\u003c\/p\u003e\n\u003ch4\u003e2.5 Cu. Ft. Firebox\u003c\/h4\u003e\n\u003cp\u003eThe 2.5 cu. ft. firebox burns dry, seasoned cordwood and accepts logs up to 20\" long loaded east-west. The current owner's manual recommends 16\" logs loaded north-south for everyday burning. Published maximum burn time is up to 9 hours, depending on wood, draft, and operating conditions.\u003c\/p\u003e\n\u003ch4\u003eNon-Catalytic Double Combustion\u003c\/h4\u003e\n\u003cp\u003eA non-catalytic double-combustion system burns the wood and then the gases it releases. Secondary-air tubes beneath the C-Cast baffle supply air to complete combustion before the exhaust enters the chimney. The system is EPA certified using cordwood at 1.14 g\/hr average particulate emissions, with a 68% (HHV) and 73% (LHV) average overall efficiency and an optimum efficiency of 74% (LHV) at a specific burn rate, per the current owner's manual.\u003c\/p\u003e\n\u003ch4\u003eIncluded Convection Blower\u003c\/h4\u003e\n\u003cp\u003eA convection blower rated up to 176 CFM is included with the fireplace, drawing room air around the firebox and returning warmed air to the living space.\u003c\/p\u003e\n\u003ch4\u003eChiseled Cast-Iron Facade\u003c\/h4\u003e\n\u003cp\u003eThe facade is European cast iron with HearthStone's chiseled stone texture, finished in Matte Black or Brown Enamel, and it ships installed on the fireplace. The single ceramic-glass door is framed in cast iron and gives the WFP-75 the open sightline of a traditional hearth.\u003c\/p\u003e\n\u003ch4\u003eRefractory Ceramic Interior\u003c\/h4\u003e\n\u003cp\u003eThe firebox is lined with refractory ceramic panels that reflect heat back into the fire for cleaner combustion and give the firebox a finished masonry appearance.\u003c\/p\u003e\n\u003ch4\u003eFlexible Heat Distribution\u003c\/h4\u003e\n\u003cp\u003eBeyond the included blower, the optional Forced Air Convection Kit (94-57110) can move heat to another room up to 50 ft away, and the optional Hot Air Distribution \/ Gravity Convection Kit (94-99100) adds two gravity hot-air outlets above the fireplace. Fresh-air connector components — a 4\" adapter, an air-inlet block-off plate, and four screws — are included with the fireplace for installations that connect outside combustion air.\u003c\/p\u003e\n\u003ch4\u003eDedicated 6-Inch Chimney System\u003c\/h4\u003e\n\u003cp\u003eThe WFP-75 uses a dedicated 6\" chimney system listed to UL 103 HT (2100°F) or CAN\/ULC S629, beginning with a listed 6\" anchor plate secured to the fireplace. The minimum straight system height is 15 ft from the base of the fireplace to the chimney cap, and the fireplace must never share a flue with any other appliance.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe WFP-75 is a single base model available in two finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatte Black\u003c\/td\u003e\n\u003ctd\u003e8411-0010\u003c\/td\u003e\n\u003ctd\u003e$5,599\u003c\/td\u003e\n\u003ctd\u003eShips with the included convection blower and fresh-air connector components.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8411-0020\u003c\/td\u003e\n\u003ctd\u003e$6,499\u003c\/td\u003e\n\u003ctd\u003eShips with the included convection blower and fresh-air connector components.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWFP-75, Model 8411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eZero-clearance wood-burning fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eDry, seasoned cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion system\u003c\/td\u003e\n\u003ctd\u003eNon-catalytic primary and secondary (double) combustion with secondary-air tubes and C-Cast baffle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output\u003c\/td\u003e\n\u003ctd\u003eUp to 80,000 BTU\/hr with dry cordwood, per the current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested overall heat output\u003c\/td\u003e\n\u003ctd\u003e14,200–48,200 BTU\/hr under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage overall efficiency\u003c\/td\u003e\n\u003ctd\u003e68% (HHV); 73% (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum efficiency\u003c\/td\u003e\n\u003ctd\u003e74% (LHV) at a specific burn rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA particulate emissions\u003c\/td\u003e\n\u003ctd\u003e1.14 g\/hr average, certified using cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended heating area\u003c\/td\u003e\n\u003ctd\u003e750 to 2,200 sq. ft., depending on home and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e20\", east-west\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended log length\u003c\/td\u003e\n\u003ctd\u003e16\", north-south, per the owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum burn time\u003c\/td\u003e\n\u003ctd\u003eUp to 9 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, listed to UL 103 HT (2100°F) or CAN\/ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaffle\u003c\/td\u003e\n\u003ctd\u003eC-Cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor\u003c\/td\u003e\n\u003ctd\u003eSingle ceramic-glass door with cast-iron frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFace dimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 35-1\/2\" W × 37\" H, arched, per the current catalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eIncluded, rated up to 176 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog listed weight\u003c\/td\u003e\n\u003ctd\u003e400 lb, per the current HearthStone catalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual listed weight\u003c\/td\u003e\n\u003ctd\u003e575 lb, including refractory panels, faceplate, and packaging, per the current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove installation\u003c\/td\u003e\n\u003ctd\u003eNot approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile \/ manufactured home installation\u003c\/td\u003e\n\u003ctd\u003eNot approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety listing\u003c\/td\u003e\n\u003ctd\u003eUL 127 (USA); ULC-S610 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish options\u003c\/td\u003e\n\u003ctd\u003eMatte Black or Brown Enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation, Clearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003e\"Zero clearance\" describes this class of built-in fireplace, not an absence of requirements. The current Model 8411 manual permits 0\" enclosure clearance at the back, sides, and floor under the fireplace, and at the same time requires the combustible clearances, noncombustible facing, hearth protection, and chimney clearance below. The current owner's manual and its drawings govern every installation; review them with your installer and local building official.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible side trim, from the door opening\u003c\/td\u003e\n\u003ctd\u003e8\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjacent combustible side wall, from the door opening\u003c\/td\u003e\n\u003ctd\u003e13\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible side-trim projection\u003c\/td\u003e\n\u003ctd\u003e3\" maximum, as shown by the manual's clearance figure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible wall in front of the fireplace\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeiling\u003c\/td\u003e\n\u003ctd\u003e80\", measured from the base of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace enclosure, back\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace enclosure, sides\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor under the fireplace\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney, to combustibles\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual publishes three hearth and floor-protection configurations. All three are reproduced below.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth Configuration\u003c\/th\u003e\n\u003cth\u003eRequired R-value\u003c\/th\u003e\n\u003cth\u003eMinimum front protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 1 — installed directly on the floor\u003c\/td\u003e\n\u003ctd\u003eR 1.00\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 2 — raised 4\" or less from the floor\u003c\/td\u003e\n\u003ctd\u003eR 1.00\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 3 — raised more than 4\" from the floor\u003c\/td\u003e\n\u003ctd\u003eNo R-value requirement\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn every configuration, the hearth protection must be at least 41-1\/2\" wide in total, extending at least 8\" beyond each side of the door opening, with sheet-metal joint protection where the manual specifies it. Confirm the applicable configuration and its construction details using the current Model 8411 manual, your installer, local code, and the authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003eFraming and facing requirements include the following. These reference values do not replace the manual's complete installation drawings, and allowances may need to increase for the fresh-air kit, the forced-air kit, or the finish materials used.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming and Facing Reference\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStraight-wall framing reference\u003c\/td\u003e\n\u003ctd\u003e37-3\/4\" wide × 23-7\/8\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming material, sides and rear\u003c\/td\u003e\n\u003ctd\u003e2\" × 3\" or heavier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectly above the fireplace\u003c\/td\u003e\n\u003ctd\u003eNo combustible framing; the zone must remain empty for 80\" from the base of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFresh-air framing allowance\u003c\/td\u003e\n\u003ctd\u003e12\" minimum on the applicable side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForced-air-kit framing allowance\u003c\/td\u003e\n\u003ctd\u003e18\" minimum on the applicable side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorner framing references\u003c\/td\u003e\n\u003ctd\u003e50-1\/4\" on each angled wall, 14-3\/8\" on each return, and 79-3\/4\" across the front, as shown by the manufacturer drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFacing\u003c\/td\u003e\n\u003ctd\u003eMaterials directly in front of the fireplace must be noncombustible within the area defined by the manual's facing drawing; the faceplate must remain removable after the finish is installed; faceplate projection minimum 3\/8\", maximum 1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoncombustible shelf\u003c\/td\u003e\n\u003ctd\u003ePermitted at 48\" or more from the base of the fireplace, regardless of shelf depth; the manual identifies this shelf as noncombustible and warns that it will be hot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eA combustible mantel or shelf must follow the current manual's shelf tables. Without the optional mantel shield, a 6\"-deep combustible shelf must be at least 58\" above the base of the fireplace, an 8\" shelf at least 60\", a 10\" shelf at least 62\", and a 12\" shelf at least 64\". With the Mantel Shield (94-79700) installed, those minimums become 50\", 52\", 54\", and 56\" respectively. For other shelf depths, the manual provides its calculation method. The current manual and accessory instructions control final mantel and shelf installation.\u003c\/p\u003e\n\u003cp\u003eThe chimney is a dedicated listed 6\" system (UL 103 HT or CAN\/ULC S629) beginning with a listed 6\" anchor plate secured to the fireplace; the manual notes the anchor plate is sold separately. The minimum system height for a straight installation is 15 ft from the base of the fireplace to the chimney cap. Where offsets are used, the manual calls for a recommended minimum 18\" rise before the first offset, a 15 ft minimum system height with two elbows, and a 17 ft minimum with four elbows. The chimney must terminate at least 3 ft above its point of contact with the roof and at least 2 ft higher than any wall, roof, or building within 10 ft, must be braced if it extends more than 5 ft above the roof, must carry a rain cap, and must maintain 2\" clearance to combustibles. A chimney venting this fireplace must not vent any other appliance. Alcove and mobile\/manufactured-home installations are not approved.\u003c\/p\u003e\n\u003cp\u003eThe WFP-75 is a zero-clearance fireplace, not a fireplace insert, and it has not been tested for installation inside a masonry chimney. For applications that connect to an existing masonry chimney, the current manual requires the chimney to be inspected, maintained with at least 1\" clearance between the exterior masonry and combustible framing or loose insulation, and relined with a listed stainless-steel liner of the same diameter as the fireplace flue outlet; no other appliance may share the chimney, and U.S. angled-connection limitations follow the exact manual.\u003c\/p\u003e\n\u003cp\u003eA supply of outside combustion air is strongly recommended and is required by some jurisdictions and codes. The fresh-air connector components included with the fireplace are a 4\" adapter, an air-inlet block-off plate, and four screws; the 4\" insulated flexible duct, outside wall termination, and two adjustable clamps are not included. The intake connects at the right side or right underside of the fireplace per the manual. The manual recommends at least 10 ft of insulated pipe to avoid condensation, with a maximum duct length of 30 ft. The outside termination must not be located more than 50% of the total chimney height, more than 10 ft above the fireplace base, or more than 3 ft below it. Combustion air must come from outside the home — never from an attic, basement, or garage.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConvection blower, rated up to 176 CFM (included)\u003c\/li\u003e\n\u003cli\u003eFresh-air connector components: 4\" adapter, air-inlet block-off plate, and four screws (included with the fireplace)\u003c\/li\u003e\n\u003cli\u003eChiseled cast-iron facade in the selected finish (ships installed)\u003c\/li\u003e\n\u003cli\u003eSingle ceramic-glass door with cast-iron frame (ships installed)\u003c\/li\u003e\n\u003cli\u003eRefractory ceramic firebox panels (integral to the appliance)\u003c\/li\u003e\n\u003cli\u003eC-Cast baffle and secondary-air tubes (integral combustion components)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4\" insulated flexible fresh-air duct, outside wall termination, and adjustable clamps are not included and are supplied by the installer when outside air is connected. Chimney components, including the 6\" anchor plate, are sold separately.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cp\u003eAccessories are sold separately and installed per their instructions and the current Model 8411 manual.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForced Air Convection Kit\u003c\/td\u003e\n\u003ctd\u003e94-57110\u003c\/td\u003e\n\u003ctd\u003e$1,299\u003c\/td\u003e\n\u003ctd\u003eConnects to either side of the WFP-75 — the manual notes the left side provides better performance — and can distribute heat to another room up to 50 ft away when installed to the manufacturer's instructions. Insulated flexible HVAC pipe is not included, and ducting must meet the applicable ULC S110 \/ UL 181 requirements and temperature rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel Shield\u003c\/td\u003e\n\u003ctd\u003e94-79700\u003c\/td\u003e\n\u003ctd\u003e$239\u003c\/td\u003e\n\u003ctd\u003ePermits the reduced combustible-shelf heights shown in the manual's heat-shield table (50\" to 56\" depending on shelf depth). Install per the current manual and accessory instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Air Distribution \/ Gravity Convection Kit\u003c\/td\u003e\n\u003ctd\u003e94-99100\u003c\/td\u003e\n\u003ctd\u003e$429\u003c\/td\u003e\n\u003ctd\u003eAdds two gravity hot-air outlets; both outlets must be installed, at least 68\" above the base of the fireplace, with a maximum duct length of 10 ft including elbows, no more than two elbows per duct, and 12\" minimum from the outlet frame to combustible ceilings, side walls, or mantels. Rigid 8\" ducting is not included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe WFP-75 is covered by the limited warranty published in the current Model 8411 owner's manual. In summary: combustion chamber welds, castings, the convector air-mate, and ceramic glass against thermal breakage carry lifetime parts coverage with four years of labor; plating carries lifetime parts coverage for manufacturing defects, subject to the written terms; stainless-steel firebox components, surrounds and heat shields, the C-Cast baffle, and secondary-air tubes carry five years parts and three years labor; carbon-steel firebox components, glass retainers, and the handle assembly carry three years parts and two years labor; blowers, heat sensors, switches, rheostats, wiring, and controls carry two years parts and one year labor; and paint peeling, gaskets, insulation, and firebrick carry one year parts coverage. Lifetime coverage is subject to a one-time replacement limit. Coverage applies to the original consumer purchaser of a brand-new product in normal residential use, is not transferable, and requires authorized, qualified installation. See the current written warranty for complete terms.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built stoves prized for long-lasting, comfortable heat for more than four decades. The WFP-75 pairs HearthStone's chiseled European cast iron with an EPA-certified zero-clearance wood fireplace, offered through authorized dealers.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the WFP-75, current pricing, and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53707956388116,"sku":"8411","price":5599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/WFP758411_matteblack_200218.webp?v=1787447149"},{"product_id":"hearthstone-stoves-deva-8220-wood-cook-stove","title":"Hearthstone Stoves Deva 8220 Wood Cook Stove","description":"\u003ch2\u003eWood-Fired Cooking, Baking and Room Heat from a Single Cast-Iron Range\u003c\/h2\u003e\n\u003cp\u003eThe Deva (Model 8220) is a wood-fired cook stove with a 2.5 cu. ft. stainless-steel baking oven, a ceramic glass cooktop, and a maximum heat output of 46,000 BTU\/hr.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 cu. ft. stainless-steel baking oven\u003c\/strong\u003e — equipped with racks; HearthStone describes the oven as large enough to cook a 20-pound turkey. The current owner's manual prints the exact oven capacity as 2.47 cu. ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVitreoceramic cooking surface\u003c\/strong\u003e — HearthStone describes the ceramic glass cooktop as easy to clean, scratch resistant, and spacious enough for a number of pots and pans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum heat output 46,000 BTU\/hr of cordwood\u003c\/strong\u003e — the current owner's manual qualifies this figure as based on independent laboratory test results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.6 cu. ft. firebox\u003c\/strong\u003e — burns natural cordwood, with a maximum log length of 17\" through the fuel loading door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable oven temperature control\u003c\/strong\u003e — a single control regulates the amount of hot air circulating around the oven, per the current HearthStone product information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlue bypass system\u003c\/strong\u003e — a push-pull handle at the top center of the stove opens a direct flue route to help establish draft on a cold start, then closes to route hot gases around the oven.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-catalytic wood combustion with secondary combustion\u003c\/strong\u003e — the current Model 8220 manual describes a secondary combustion system, and the Deva is a non-catalytic appliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAsh pan included\u003c\/strong\u003e — located under the fuel loading door and removed through the ash door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop or rear 6\" flue exit\u003c\/strong\u003e — the flue collar can be relocated from the top exit to the rear exit using the procedure in the current manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA Rating: Exempt\u003c\/strong\u003e — per current HearthStone consumer information; the appliance is tested to UL 1482-2022 and ULC S627-2021.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eWood-Fired Cooking and Heat\u003c\/h4\u003e\n\u003cp\u003eThe Deva is a freestanding wood cook stove, not a wood space heater and not a gas or electric range. A single cordwood fire in the 1.6 cu. ft. firebox heats the ceramic glass cooktop, the stainless-steel oven, and the room around it. The current owner's manual publishes a maximum heat output of 46,000 BTU\/hr of cordwood, based on independent laboratory test results. The manual identifies the appliance as the Deva 100; HearthStone's current consumer material calls it the Deva. Both names refer to Model 8220.\u003c\/p\u003e\n\u003ch4\u003e2.5 Cu. Ft. Stainless-Steel Oven\u003c\/h4\u003e\n\u003cp\u003eThe oven is constructed from stainless steel, is equipped with racks, and is described by HearthStone as large enough to cook a 20-pound turkey. Current HearthStone consumer material and the 2026 catalog publish the oven capacity as 2.5 cu. ft.; the current owner's manual prints 2.47 cu. ft. An analog oven thermometer is fitted to the oven door area so the cook can read oven temperature directly.\u003c\/p\u003e\n\u003ch4\u003eVitreoceramic Cooking Surface\u003c\/h4\u003e\n\u003cp\u003eThe cooktop is a vitreoceramic (ceramic glass) surface. HearthStone describes it as easy to clean, scratch resistant, and spacious enough for a number of pots and pans.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Oven Temperature Control\u003c\/h4\u003e\n\u003cp\u003eA simple control regulates the amount of hot air circulating around the oven, which HearthStone presents as the means of holding a consistent baking temperature. Oven performance depends on fuel, draft, and how the stove is operated.\u003c\/p\u003e\n\u003ch4\u003e1.6 Cu. Ft. Firebox\u003c\/h4\u003e\n\u003cp\u003eThe firebox holds 1.6 cu. ft. and accepts logs up to 17\" long through a 7\" × 9-3\/4\" fuel loading door. The current manual directs that natural wood only be burned and specifically prohibits kiln-dried wood, painted or treated wood, solvents, trash, plywood, colored or glossy paper, artificial logs, cardboard, coal, garbage and driftwood, along with gasoline, kerosene, lighter fluid, other liquid fuels and solid fire starters. A primary air control on the ash door regulates the air entering the firebox.\u003c\/p\u003e\n\u003ch4\u003eFlue Bypass System\u003c\/h4\u003e\n\u003cp\u003eThe flue bypass is a handle at the top center of the stove that pushes in and pulls out. Opened, it gives flue gases a direct route out so the chimney heats and draft establishes faster on a cold start. Closed, hot gases travel their normal route around the oven. The current manual warns that burning the Deva 100 with the bypass open will not allow the oven to reach maximum temperatures.\u003c\/p\u003e\n\u003ch4\u003eIncluded Ash Pan\u003c\/h4\u003e\n\u003cp\u003eAn ash pan sits under the fuel loading door and collects ash from the fire. It is reached through the ash door and slides out for emptying. The current manual directs that ashes be removed only when the stove is cold.\u003c\/p\u003e\n\u003ch4\u003eTop-or-Rear 6-Inch Venting\u003c\/h4\u003e\n\u003cp\u003eThe Deva vents through a 6\" diameter flue collar at either the top or the rear of the stove. The current manual gives the procedure for moving the collar to the rear exit and covering the top exit with the block-off plate. Choice of exit affects the published clearances and, for a horizontal connector, adds a floor-protection requirement beneath the connector.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finish and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe Deva is offered in one current configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Enamel\u003c\/td\u003e\n\u003ctd\u003e8220-0050\u003c\/td\u003e\n\u003ctd\u003e$7,349\u003c\/td\u003e\n\u003ctd\u003eSingle current configuration; ash pan included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8220 (Deva)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName in the owner's manual\u003c\/td\u003e\n\u003ctd\u003eDeva 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eWood-fired cook stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion\u003c\/td\u003e\n\u003ctd\u003eNon-catalytic, with a secondary combustion system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output\u003c\/td\u003e\n\u003ctd\u003e46,000 BTU\/hr of cordwood, based on independent laboratory test results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA rating\u003c\/td\u003e\n\u003ctd\u003eExempt, per current HearthStone consumer information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e1.6 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOven capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 cu. ft. (2.47 cu. ft. in the owner's manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimensions\u003c\/td\u003e\n\u003ctd\u003e40\" W × 23-3\/4\" D × 33-3\/4\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel loading door\u003c\/td\u003e\n\u003ctd\u003e7\" × 9-3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue exit and diameter\u003c\/td\u003e\n\u003ctd\u003eTop or rear, 6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e484 lb, per current HearthStone consumer information and the 2026 catalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooktop\u003c\/td\u003e\n\u003ctd\u003eVitreoceramic (ceramic glass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOven\u003c\/td\u003e\n\u003ctd\u003eStainless steel, equipped with racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsh pan\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside combustion air\u003c\/td\u003e\n\u003ctd\u003eNo additional outside-air kit is required or offered for the Deva 8220 per the current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile \/ manufactured home installation\u003c\/td\u003e\n\u003ctd\u003eNot approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeping room installation\u003c\/td\u003e\n\u003ctd\u003eDo not install\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory-built fireplace installation\u003c\/td\u003e\n\u003ctd\u003eNot approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove installation\u003c\/td\u003e\n\u003ctd\u003eApproved, subject to the manual's alcove dimensions and clearances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety certification\u003c\/td\u003e\n\u003ctd\u003eTested to UL 1482-2022 and ULC S627-2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification report reference\u003c\/td\u003e\n\u003ctd\u003eF20-643\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOwner's and installation manual\u003c\/td\u003e\n\u003ctd\u003e6400-40460, R: 1\/6\/2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eBlack Enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe current Model 8220 manual is the governing source for every clearance and hearth requirement. The customer-readable side and rear clearances below come from HearthStone's current published summary; the manual's own lettered clearance table carries the complete set and must be used for installation planning. The Deva is to be installed as a freestanding cook stove.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector and flue exit\u003c\/th\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eRear\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, top exit\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, rear exit\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, top exit\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, rear exit\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChimney connector clearance is a separate requirement and is not covered by the appliance clearances above. The current manual states that the single-wall connector clearances it shows are generic and that the double-wall clearances shown are specific to Simpson Dura-Vent DVL, and it directs the installer to check the specifications from the manufacturer of the connector actually used. A close-clearance connector pipe must be tested and listed to UL standards, and its own listing governs its clearances. The manual also notes that clearances to combustible surfaces may be reduced using an NFPA-approved wall protection system, referring the installer to NFPA 211 for specifications and complete details. Do not apply a protected-surface reduction to the base values above without following the manual and NFPA 211.\u003c\/p\u003e\n\u003cp\u003eFloor protection is required. The following values come from the current Model 8220 manual and HearthStone's current published hearth-pad summary.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth and floor protection\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired thermal protection\u003c\/td\u003e\n\u003ctd\u003eR-value of at least 0.89, or a UL-listed floor protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension beyond the fuel loading door — United States\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension beyond the fuel loading door — Canada\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension beyond each side of the cook stove\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum overall pad width\u003c\/td\u003e\n\u003ctd\u003e56\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall pad depth — United States\u003c\/td\u003e\n\u003ctd\u003e39-3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall pad depth — Canada\u003c\/td\u003e\n\u003ctd\u003e41-3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear-exit \/ horizontal connector installations\u003c\/td\u003e\n\u003ctd\u003eFloor protection must be installed beneath the connector and extend 2\" beyond each side of the connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe manual gives R-value conversion formulas for floor protectors specified by K-factor or C-factor, and allows the R-values of multiple layers to be added. Confirm the final assembly with your installer, local code, and the authority having jurisdiction.\u003c\/p\u003e\n\u003ch3\u003eAlcove Installation\u003c\/h3\u003e\n\u003cp\u003eUnlike several other HearthStone appliances, the Deva has published alcove installation requirements. The manual's alcove clearance table is printed for the top-exit connector configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAlcove requirement\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum alcove depth\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove height\u003c\/td\u003e\n\u003ctd\u003e96\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove width, single-wall connector\u003c\/td\u003e\n\u003ctd\u003e63\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum alcove width, double-wall connector\u003c\/td\u003e\n\u003ctd\u003e58\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe alcove clearances themselves are published in the manual as a lettered table with separate single-wall and double-wall connector columns. Consult the current Model 8220 manual's alcove table for the full connector-specific requirements before planning an alcove installation.\u003c\/p\u003e\n\u003ch3\u003eChimney and Venting Requirements\u003c\/h3\u003e\n\u003cp\u003eThe Deva requires a 6\" inside diameter flue for a new installation. An existing 8\" diameter flue may be used with a reducer. A prefabricated metal chimney must be Type HT (2100°F), listed to UL 103 or ULC S629. A lined masonry chimney may also be used; the manual specifies brick or modular block at least 4\" thick or a rubble or stone wall at least 12\" thick, a flue liner at least 5\/8\" thick installed with refractory mortar and at least a 1\" air space, at least 2\" clearance to combustible structure inside the building and at least 1\" outside it, and identifies an 8\" × 8\" tile flue as the size that gives best results. Have an existing masonry chimney professionally inspected before installation and make sure the cleanout is functional and sealed.\u003c\/p\u003e\n\u003cp\u003eMinimum chimney height is 13 ft and maximum chimney height is 30 ft. The Deva requires a draft between 0.06\" w.c. and 0.10\" w.c.; for drafts above 0.10\" w.c. the manual requires a stovepipe damper. Horizontal runs of stovepipe must rise away from the stove a minimum of 1\/4\" per foot. Do not connect this stove to a chimney serving another appliance. The chimney must terminate at least 3 ft higher than the highest part of the roof opening and at least 2 ft higher than any part of the roof within 10 ft.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAsh pan (included)\u003c\/li\u003e\n\u003cli\u003eStainless-steel baking oven, equipped with racks (integral appliance components)\u003c\/li\u003e\n\u003cli\u003eVitreoceramic cooking surface (integral appliance component)\u003c\/li\u003e\n\u003cli\u003eAnalog oven thermometer (integral control shown in the manual's controls and features figure)\u003c\/li\u003e\n\u003cli\u003eFlue bypass system (integral)\u003c\/li\u003e\n\u003cli\u003ePrimary air control (integral)\u003c\/li\u003e\n\u003cli\u003eRefractory firebox components (integral appliance components)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe current Model 8220 manual does not print a formal itemized pack list; the items above are the equipment confirmed by current official HearthStone sources. The manual directs that the stove and all parts be inspected on delivery and that a dealer be contacted immediately if anything is damaged or missing.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cp\u003eNo separately priced Deva accessories are listed in HearthStone's current dealer pricing, and HearthStone's current Deva product information states that there are no accessories listed for this product yet. No outside-air kit is offered for this appliance. Contact Cozy Glow Stoves for current service, replacement-part, or installation-component availability.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Deva is covered by HearthStone's applicable limited manufacturer warranty. Coverage, exclusions, eligibility, and claim requirements are governed by the current HearthStone warranty policy supplied with the appliance. Warranty registration is not required for coverage — HearthStone's current warranty and registration information states that completion of the warranty registration form is not required to be eligible to receive warranty parts or service, and the manual's own warranty registration page states that sending in the signed registration form is not a condition of warranty coverage. Retain your proof of purchase.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built wood and gas hearth appliances for more than four decades. The Deva is HearthStone's wood cook stove: one cordwood fire serving a baking oven, a ceramic glass cooktop, and the room.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the Deva, current pricing, and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53708157649172,"sku":"8220","price":7349.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Deva8220_nobackground.webp?v=1787451326"},{"product_id":"hearthstone-stoves-bristol-8764-direct-vent-gas-stove","title":"Hearthstone Stoves Bristol 8764 Direct Vent Gas Stove","description":"\u003ch2\u003eThree-Sided Direct Vent Gas Heat with Push-Button Convenience\u003c\/h2\u003e\n\u003cp\u003eThe Bristol (Model 8764) is a freestanding direct vent gas stove with a three-sided fire view, a cast-iron heat exchanger, and a maximum input of 26,500 BTU\/hr.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-sided view of the fire\u003c\/strong\u003e — HearthStone describes the Bristol as offering a beautiful 3-sided view of the fire, with the quality of the appliance displayed in the intricate details of the cast iron.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIT 821 gas system with 7-day pilot timeout\u003c\/strong\u003e — the current owner's manual states that the automatic timer shuts the pilot off after 7 days of inactivity. HearthStone presents this as meeting newer safety standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e26,500 BTU\/hr maximum input\u003c\/strong\u003e — on natural gas and on propane. Minimum input is 15,000 BTU\/hr on natural gas and 14,000 BTU\/hr on propane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats up to 1,400 sq. ft.\u003c\/strong\u003e — per current HearthStone consumer information. Actual heated area depends on layout, insulation, and climate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCast-iron heat exchanger\u003c\/strong\u003e — HearthStone states that all Traditions Family gas stoves incorporate a cast-iron heat exchanger, and that air flows through the heat exchanger to circulate more heat from the stove into the home.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShips configured for natural gas with an LP conversion kit included\u003c\/strong\u003e — the certified LP conversion kit (97-56641) is packed with the appliance and must be installed by a qualified installer for propane operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePan burner with a 4-piece decorative ceramic log set\u003c\/strong\u003e — supplied with Platinum Bright Embers and ceramic nuggets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral safety barrier screen\u003c\/strong\u003e — HearthStone describes each window into the fire as protected by a nearly invisible screen, seamlessly integrated into the stove.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop-vent 4\" × 6-5\/8\" direct vent\u003c\/strong\u003e — vertical and horizontal terminations are both permitted, within the limits published in the current manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved for mobile home installation\u003c\/strong\u003e — per the current Model 8764 manual, where not prohibited by local codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eThree-Sided Fire View\u003c\/h4\u003e\n\u003cp\u003eThe Bristol presents the fire through glass on three sides. HearthStone's current product information describes a beautiful 3-sided view of the fire, careful craftsmanship and reliable technology, with the quality of the product displayed in the intricate details of the cast iron and the warm flickering glow of the fire. Each viewing window is fitted with an integral safety barrier screen.\u003c\/p\u003e\n\u003ch4\u003eSIT 821 Gas Control with 7-Day Pilot Timeout\u003c\/h4\u003e\n\u003cp\u003eThe Bristol uses a SIT 821 gas valve. It is a millivolt system: the pilot flame heats a thermopile, which generates the millivoltage that powers the gas control valve. The pilot itself is lit with the appliance's continuous sparker rather than a match. The current manual states that the appliance has a 7-day time-out pilot assembly and that the automatic timer shuts the pilot off after 7 days of inactivity. The manual instructs that the 7-day timer system must not be defeated. This is not a conventional pilot that burns indefinitely without regard to use.\u003c\/p\u003e\n\u003ch4\u003eNatural Gas with Included LP Conversion Kit\u003c\/h4\u003e\n\u003cp\u003eThe Bristol ships configured for natural gas. A certified LP conversion kit, part 97-56641, is included with the appliance and is required for propane operation. Conversion must be carried out by a qualified installer following the current manual. The appliance operates on one fuel at a time; it is not a dual-fuel appliance. The appliance is equipped for use at 0 to 2,000 ft altitude.\u003c\/p\u003e\n\u003ch4\u003eCast-Iron Construction and Heat Exchanger\u003c\/h4\u003e\n\u003cp\u003eHearthStone states that all Traditions Family gas stoves incorporate a cast-iron heat exchanger, and that air flows through the heat exchanger to circulate more heat from the stove into the home rather than up the chimney. The Bristol is offered in Matte Black, Brown Enamel and Basil Enamel.\u003c\/p\u003e\n\u003ch4\u003ePan Burner and Ceramic Log Set\u003c\/h4\u003e\n\u003cp\u003eThe current HearthStone product information identifies the Bristol's burner as a Pan Burner. HearthStone's technical resource page for Model 8764 describes it as a stainless steel burner; the current manual's parts list calls it a steel burner. The appliance is supplied with a 4-piece decorative ceramic log set, a bag of Platinum Bright Embers and a bag of ceramic nuggets. Log, ember and nugget placement must follow the current manual exactly.\u003c\/p\u003e\n\u003ch4\u003eOptional Blower and Remote Controls\u003c\/h4\u003e\n\u003cp\u003eA convection blower kit (93-57100) is available separately and is not included. The blower assembly includes a rheostat speed control and a snap switch that starts the fan once the stove chassis reaches its preset temperature; it requires a grounded 120V receptacle. Two remote control kits are offered separately: a Programmable Thermostatic Remote (90-56917) and a Thermostatic Remote (90-56914). No remote is included with the appliance. The standard appliance can also be operated from its own ON\/OFF\/T-STAT control or from a wall-mounted 750-millivolt thermostat, which is not supplied with the appliance.\u003c\/p\u003e\n\u003ch4\u003eDirect Vent Installation\u003c\/h4\u003e\n\u003cp\u003eThe Bristol is a direct vent appliance using 4\" × 6-5\/8\" coaxial pipe with a top vent connection. It may be terminated vertically through the roof or horizontally through a wall, within the limits published in the current manual, and it may not share a vent with any other appliance. The current manual also permits approved direct vent chimney conversion methods in a lined masonry chimney or in a listed prefabricated solid-fuel chimney, under the manual's own conditions. The manual notes that use of an existing chimney as the air intake is not covered by the ANSI Z21.88 \/ CSA 2.33-2019 test methods, that this installation was tested and approved by PFS-TECO Laboratories, and that the code authority having jurisdiction must be consulted before proceeding.\u003c\/p\u003e\n\u003ch4\u003eMobile Home Certified\u003c\/h4\u003e\n\u003cp\u003eThe current Model 8764 manual states that the appliance may be installed in an aftermarket permanently located manufactured home in the United States where not prohibited by local codes, and that the installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eAll three finishes are the same base appliance, Model 8764, and all three ship configured for natural gas with the LP conversion kit included. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eFuel configuration\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatte Black\u003c\/td\u003e\n\u003ctd\u003e8764-0010\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas; LP conversion kit included\u003c\/td\u003e\n\u003ctd\u003e$4,949\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8764-0020\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas; LP conversion kit included\u003c\/td\u003e\n\u003ctd\u003e$5,349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasil Enamel\u003c\/td\u003e\n\u003ctd\u003e8764-0083\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas; LP conversion kit included\u003c\/td\u003e\n\u003ctd\u003e$5,349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe blower and the remote controls are ordered separately and are listed under Compatible Accessories. Contact Cozy Glow Stoves for current availability and lead times.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed as\u003c\/td\u003e\n\u003ctd\u003eDirect Vent Gas Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas factory configuration; certified LP conversion kit (97-56641) included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input\u003c\/td\u003e\n\u003ctd\u003e26,500 BTU\/hr natural gas; 26,500 BTU\/hr propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum input\u003c\/td\u003e\n\u003ctd\u003e15,000 BTU\/hr natural gas; 14,000 BTU\/hr propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeats up to\u003c\/td\u003e\n\u003ctd\u003e1,400 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Efficiency\u003c\/td\u003e\n\u003ctd\u003e70% natural gas; 72% propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP.4.1.09 Efficiency\u003c\/td\u003e\n\u003ctd\u003e63.4% natural gas; 65.8% propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas system \/ ignition\u003c\/td\u003e\n\u003ctd\u003eSIT 821 with 7-day pilot timeout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurner\u003c\/td\u003e\n\u003ctd\u003ePan Burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger\u003c\/td\u003e\n\u003ctd\u003eCast iron, integral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety barrier\u003c\/td\u003e\n\u003ctd\u003eIntegral screens over the viewing glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e4\" × 6-5\/8\" direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting location\u003c\/td\u003e\n\u003ctd\u003eTop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately (93-57100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately (90-56917 or 90-56914)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall thermostat\u003c\/td\u003e\n\u003ctd\u003e750 millivolt; not supplied with the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile home\u003c\/td\u003e\n\u003ctd\u003eApproved for mobile home installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eEquipped for use at 0 to 2,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e170 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth (front)\u003c\/td\u003e\n\u003ctd\u003e22-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e26-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront-to-rear (top-plan drawing reference)\u003c\/td\u003e\n\u003ctd\u003e19-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas connection\u003c\/td\u003e\n\u003ctd\u003e3\/8\" male NPT at the gas control valve; 1\/2\" supply piping recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting agency\u003c\/td\u003e\n\u003ctd\u003ePFS TECO, file 22-832\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested to\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.88-2019 \/ CSA 2.33-2019; CSA 2.17-2017; efficiency tested to CSA P.4.1-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOwner's and installation manual\u003c\/td\u003e\n\u003ctd\u003e6400-40585, R: 7\/6\/26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinishes\u003c\/td\u003e\n\u003ctd\u003eMatte Black, Brown Enamel, Basil Enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe manual's dimension drawing also prints a 15-1\/4\" front-to-rear reference on the side-body view. The 15-1\/4\" and 19-1\/4\" references are taken between different points on the appliance and are not competing values. Confirm final dimensions against the current Model 8764 manual before planning an installation.\u003c\/p\u003e\n\u003ch3\u003eClearances and Floor Protection\u003c\/h3\u003e\n\u003cp\u003eThe current Model 8764 manual is the governing source for every clearance and installation requirement. The values below are the published standard appliance clearances.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eMinimum\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorner\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe manual specifies the 4\" corner clearance measured from the edge of the top castings to the adjacent wall. Vent pipe clearances are a separate requirement and are not covered by the appliance clearances above: the manual requires 1\" to combustibles along vertical runs, 1\" below and to the sides of horizontal runs, and 2\" above horizontal runs. Where a vent pipe clearance is larger than the appliance clearance at the same point, the vent pipe clearance governs. Mantel and trim clearances are published separately in the manual's clearance figures and must also be satisfied.\u003c\/p\u003e\n\u003cp\u003eFloor protection requirements are as follows.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFloor surface\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoncombustible surface\u003c\/td\u003e\n\u003ctd\u003eThe appliance may be placed directly on the surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWood floor\u003c\/td\u003e\n\u003ctd\u003eThe appliance may be placed directly on the floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther combustible surface\u003c\/td\u003e\n\u003ctd\u003eInstall a panel of metal, wood, stone or glass under the appliance, extending the full width and depth of the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual notes that some luxury vinyl plank and luxury vinyl tile products begin to warp at relatively low temperatures, that every installation and flooring specification is different, and that additional shielding may be necessary depending on the flooring used. Check the flooring manufacturer's temperature limits with your installer before installing over vinyl flooring.\u003c\/p\u003e\n\u003ch3\u003eDirect Vent Requirements\u003c\/h3\u003e\n\u003cp\u003eThe Bristol uses a 4\" × 6-5\/8\" direct vent system connected at the top of the appliance. It may not be vented into a shared vent system. The planning limits below come from the current Model 8764 manual; the manual's complete venting instructions, its vent termination clearance figure and its venting termination chart govern the actual installation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVertical termination\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum vertical pipe\u003c\/td\u003e\n\u003ctd\u003e11 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum vertical run\u003c\/td\u003e\n\u003ctd\u003e35 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical vent restrictor kit\u003c\/td\u003e\n\u003ctd\u003eIncluded with the appliance and required for vertical termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum elbows\u003c\/td\u003e\n\u003ctd\u003eTwo 90-degree elbows or four 45-degree elbows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination cap\u003c\/td\u003e\n\u003ctd\u003eNo less than 18\" horizontally from any roof or vertical surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHorizontal termination\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum vertical rise off the appliance\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum vertical rise with a 14\" or larger snorkel\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum horizontal run at minimum rise\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum horizontal run at minimum rise\u003c\/td\u003e\n\u003ctd\u003e8 ft, with 1\/4\" of rise for every 12\" of horizontal run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum horizontal run with 3 ft of vertical rise\u003c\/td\u003e\n\u003ctd\u003e10 ft, with 1\/4\" of rise for every 12\" of horizontal run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall pass-through\u003c\/td\u003e\n\u003ctd\u003eMinimum 10\" × 10\" framed opening, with 2\" minimum clearance maintained at the top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eVent termination clearances to windows, doors, soffits, corners, grade, decks, gas meters and regulators, air inlets and public walkways are published as a lettered figure in the current manual, with separate United States and Canada values for several of them. The manual also sets air restrictor positions by vent configuration; these are installer settings and are made at installation. Your HearthStone installer will select the vent configuration, the restrictor setting and the termination location for your home.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBristol 8764 gas-fired direct vent heater\u003c\/li\u003e\n\u003cli\u003eBurner\u003c\/li\u003e\n\u003cli\u003eOwner's packet (manual)\u003c\/li\u003e\n\u003cli\u003eLP conversion kit (97-56641)\u003c\/li\u003e\n\u003cli\u003eDecorative ceramic log set, 4 pieces, in a separate box\u003c\/li\u003e\n\u003cli\u003eBag of Platinum Bright Embers\u003c\/li\u003e\n\u003cli\u003eBag of ceramic nuggets\u003c\/li\u003e\n\u003cli\u003eVertical vent restrictor kit\u003c\/li\u003e\n\u003cli\u003eSafety barrier screens (integral)\u003c\/li\u003e\n\u003cli\u003eSIT 821 gas valve and pilot system (integral)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVent pipe, vent components and termination kits are supplied separately and are selected for the specific installation. A convection blower and a remote control are not included. Inspect the appliance and all parts on delivery and contact your dealer immediately if anything is damaged or missing.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Thermostatic Remote Control\u003c\/td\u003e\n\u003ctd\u003e90-56917\u003c\/td\u003e\n\u003ctd\u003e$399\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately. Not included with the appliance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostatic Remote Control\u003c\/td\u003e\n\u003ctd\u003e90-56914\u003c\/td\u003e\n\u003ctd\u003e$229\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately. Listed in the current manual as the optional remote control kit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvection Blower Kit\u003c\/td\u003e\n\u003ctd\u003e93-57100\u003c\/td\u003e\n\u003ctd\u003e$499\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately. Requires a grounded 120V receptacle. Includes a rheostat speed control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese are the accessories listed for Model 8764 in HearthStone's current dealer pricing and on HearthStone's current Bristol product information. Contact Cozy Glow Stoves for current availability and for vent components.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Bristol is covered by HearthStone's limited manufacturer warranty as printed in the current Model 8764 owner's manual, which defines its Limited Lifetime coverage as 10 years from the beginning of warranty coverage. For gas appliances the manual's warranty table covers stone and cast iron not listed elsewhere under Limited Lifetime; door handles and latches, steel components and firebox, and burner and logs for 5 years; appliance electrical and gas components and refractory, vermiculite panels and baffles for 2 years; and enamel finish against peeling or fading, accessories, glass and all components not listed elsewhere for 1 year. Warranty labor is covered during the first year only, at HearthStone's published labor rates, and only where the appliance was installed by an authorized dealer or their designated representative. Coverage applies only to components present on this appliance. Exclusions, eligibility and claim requirements are governed by the warranty as printed in the manual supplied with the appliance. Retain your proof of purchase.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built wood and gas hearth appliances for more than four decades. The Bristol is part of HearthStone's Traditions Family of gas stoves, all of which use a cast-iron heat exchanger.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the Bristol 8764, current pricing, fuel configuration and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53719016079636,"sku":"8764","price":4949.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Bristol8763_matteblack_01.webp?v=1787708475"},{"product_id":"hearthstone-stoves-champlain-8304-direct-vent-gas-stove","title":"Hearthstone Stoves Champlain 8304 Direct Vent Gas Stove","description":"\u003ch2\u003eClassic Cast-Iron Styling with 35,000 BTU Direct Vent Gas Heat\u003c\/h2\u003e\n\u003cp\u003eThe Champlain (Model 8304) is a freestanding direct vent gas stove with a steel pan burner, a cast-iron heat exchanger, and a maximum input of 35,000 BTU\/hr.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIT 820 Nova millivolt gas system with a 7-day pilot timeout\u003c\/strong\u003e — the current owner's manual states that the appliance is equipped with a gas valve which will extinguish the pilot light after 7 days of inactivity of the main burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e35,000 BTU\/hr maximum input\u003c\/strong\u003e — on natural gas and on propane. Minimum input is 21,000 BTU\/hr on both fuels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats up to 1,800 sq. ft.\u003c\/strong\u003e — per current HearthStone consumer information. Actual heated area depends on layout, insulation, and climate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e74.6% steady state efficiency\u003c\/strong\u003e — with a published P.4.1.09 efficiency of 67.9%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCast-iron heat exchanger\u003c\/strong\u003e — HearthStone states that all of its gas stoves incorporate a cast iron heat exchanger to radiate more heat into the home.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteel pan burner with a six-piece ceramic log set\u003c\/strong\u003e — supplied with a bag of Platinum Bright Embers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShips configured for natural gas with an LP conversion kit included\u003c\/strong\u003e — the certified LP conversion kit (93-56041) is packed with the appliance and must be installed by a qualified installer for propane operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral safety barrier screen\u003c\/strong\u003e — listed by HearthStone as a standard feature of the appliance, not as an optional accessory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e45° 4\" × 6-5\/8\" direct vent connection\u003c\/strong\u003e — vertical and horizontal terminations are both permitted, within the limits published in the current manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved for mobile home installation\u003c\/strong\u003e — per the current Model 8304 manual, where not prohibited by local codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eArtfully Balanced Fire\u003c\/h4\u003e\n\u003cp\u003eHearthStone describes the Champlain as adding a touch of classic style to a room, and states that it has been carefully designed to present a balanced, gently flickering fire on both low and high settings. The fire is viewed through the front glass, which carries an integral safety barrier screen. An adjustable restrictor plate is provided to control excess draft where necessary; the manual notes that adjusting the restrictor also changes the appearance of the flame, and that the plate has a large range of settings.\u003c\/p\u003e\n\u003ch4\u003eSIT Nova with 7-Day Pilot Timeout\u003c\/h4\u003e\n\u003cp\u003eThe Champlain uses a SIT 820 Nova gas control system. It is a millivolt system: the pilot flame heats a thermopile, which generates the 325 to 500 millivolts that power the gas control valve. The pilot itself is lit with the appliance's piezoelectric spark igniter. HearthStone states that the Champlain 8304 maintains a standing pilot which shuts off after 7 days of inactivity, and the current manual states that the gas valve extinguishes the pilot light after 7 days of inactivity of the main burner. This is not a pilot that burns indefinitely without regard to use.\u003c\/p\u003e\n\u003ch4\u003eNatural Gas with Included LP Conversion Kit\u003c\/h4\u003e\n\u003cp\u003eThe Champlain is factory equipped to burn natural gas. A certified LP conversion kit, part 93-56041, is included with the appliance and is required for propane operation. Conversion must be carried out by a qualified installer following the current manual. The appliance operates on one fuel at a time; it is not a dual-fuel appliance. Maximum input is 35,000 BTU\/hr on either fuel, and the manual publishes ratings for both the 0 to 2,000 ft and the 2,000 to 4,500 ft altitude ranges. For installations above those ranges the manual directs the installer to consult the local gas distributor or the authority having jurisdiction for proper rating methods.\u003c\/p\u003e\n\u003ch4\u003eSteel Pan Burner and Ceramic Log Set\u003c\/h4\u003e\n\u003cp\u003eHearthStone's current product information identifies the Champlain's burner as a Pan Burner; the current 2026 catalog calls it a Steel Pan Burner. The appliance is supplied with six decorative ceramic logs in a separate box and a bag of Platinum Bright Embers. Log and ember placement must follow the current manual exactly.\u003c\/p\u003e\n\u003ch4\u003eCast-Iron Heat Exchanger\u003c\/h4\u003e\n\u003cp\u003eHearthStone states that all of its gas stoves incorporate a cast iron heat exchanger to radiate more heat into the home. The Champlain is offered in Matte Black, Brown Enamel and Basil Enamel.\u003c\/p\u003e\n\u003ch4\u003eOptional Blower and Remote\u003c\/h4\u003e\n\u003cp\u003eA convection blower (93-57020) is available separately and is not included with the appliance; the current manual lists the blower among the appliance's features as optional. Two remote control kits are also offered separately: a Thermostatic Remote Control (90-56914), which the manual names as the optional remote control kit, and a Programmable Thermostatic Remote Control (90-56917). No remote is included. The appliance carries a three-way ON \/ OFF \/ T-STAT control switch, and the manual describes operation in the T-STAT position with the main burner cycled by a thermostat.\u003c\/p\u003e\n\u003ch4\u003eDirect Vent Installation\u003c\/h4\u003e\n\u003cp\u003eThe Champlain is a direct vent appliance using 4\" × 6-5\/8\" coaxial pipe with a 45° connection at the appliance. It may be terminated vertically through the roof or horizontally through a wall, including with a snorkel termination, within the limits published in the current manual, and it may not share a vent with any other appliance. The manual also describes approved methods for venting through an existing masonry or listed prefabricated chimney using direct vent chimney liner termination, co-linear and co-axial adapter arrangements, under the manual's own conditions. Only vent components from the manufacturers listed in the current manual may be used.\u003c\/p\u003e\n\u003ch4\u003eMobile Home Certified\u003c\/h4\u003e\n\u003cp\u003eThe current Model 8304 manual states that the appliance may be installed in an aftermarket permanently located manufactured home in the United States where not prohibited by local codes, and references the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, together with the Canadian manufactured-home standards printed in the manual.\u003c\/p\u003e\n\u003ch4\u003eMade in USA\u003c\/h4\u003e\n\u003cp\u003eHearthStone's current gas stove catalog section presents its certified gas-fired direct vent heaters as made in Vermont, and the Model 8304 rating label carries a Made in USA marking. HearthStone states separately that its cast iron parts are produced at its own foundry in Spain.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eAll three finishes are the same base appliance, Model 8304, and all three ship configured for natural gas with the LP conversion kit included. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eFuel configuration\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatte Black\u003c\/td\u003e\n\u003ctd\u003e8304-0010NP\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas; LP conversion kit included\u003c\/td\u003e\n\u003ctd\u003e$4,499\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8304-0020NP\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas; LP conversion kit included\u003c\/td\u003e\n\u003ctd\u003e$5,049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasil Enamel\u003c\/td\u003e\n\u003ctd\u003e8304-0083NP\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas; LP conversion kit included\u003c\/td\u003e\n\u003ctd\u003e$5,049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone's current consumer literature shows the Champlain in Matte Black and Brown Enamel. Basil Enamel is a currently priced Model 8304 configuration on HearthStone's current dealer pricing. The blower and the remote controls are ordered separately and are listed under Compatible Accessories. Contact Cozy Glow Stoves for current availability and lead times.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed as\u003c\/td\u003e\n\u003ctd\u003eGas-Fired Direct Vent Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas factory configuration; certified LP conversion kit (93-56041) included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input\u003c\/td\u003e\n\u003ctd\u003e35,000 BTU\/hr natural gas; 35,000 BTU\/hr propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum input\u003c\/td\u003e\n\u003ctd\u003e21,000 BTU\/hr natural gas; 21,000 BTU\/hr propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeats up to\u003c\/td\u003e\n\u003ctd\u003e1,800 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Efficiency\u003c\/td\u003e\n\u003ctd\u003e74.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP.4.1.09 Efficiency\u003c\/td\u003e\n\u003ctd\u003e67.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas system \/ ignition\u003c\/td\u003e\n\u003ctd\u003eSIT 820 Nova millivolt system with 7-day pilot timeout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot ignition\u003c\/td\u003e\n\u003ctd\u003ePiezoelectric spark igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurner\u003c\/td\u003e\n\u003ctd\u003eSteel Pan Burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger\u003c\/td\u003e\n\u003ctd\u003eCast iron, integral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety barrier\u003c\/td\u003e\n\u003ctd\u003eIntegral safety barrier screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog set\u003c\/td\u003e\n\u003ctd\u003eSix decorative ceramic logs with Platinum Bright Embers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e4\" × 6-5\/8\" direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting location\u003c\/td\u003e\n\u003ctd\u003e45° connection at the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately (93-57020)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately (90-56914 or 90-56917)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance control\u003c\/td\u003e\n\u003ctd\u003eThree-way ON \/ OFF \/ T-STAT switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile home\u003c\/td\u003e\n\u003ctd\u003eApproved for mobile home installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e220 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e26-1\/2\" × 21-3\/8\" × 28-7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas connection\u003c\/td\u003e\n\u003ctd\u003e3\/8\" male NPT at the gas control valve; 1\/2\" supply piping recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMade in USA\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting agency\u003c\/td\u003e\n\u003ctd\u003ePFS, file 20-639\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested to\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.88-2017 \/ CSA 2.33-2017; CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOwner's and installation manual\u003c\/td\u003e\n\u003ctd\u003e6400-41424, R: 5\/31\/2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinishes\u003c\/td\u003e\n\u003ctd\u003eMatte Black, Brown Enamel, Basil Enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe manual's dimension drawing prints additional references associated with the 45° elbow vent arrangement and notes that it is shown with 45° elbow venting and that dimensions may vary depending on the venting manufacturer. Confirm final dimensions and vent geometry against the current Model 8304 manual before planning an installation.\u003c\/p\u003e\n\u003ch3\u003eClearances and Floor Protection\u003c\/h3\u003e\n\u003cp\u003eThe current Model 8304 manual is the governing source for every clearance and installation requirement. The values below are the published standard appliance clearances.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eMinimum\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide, with snorkel termination\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorner\u003c\/td\u003e\n\u003ctd\u003e4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel depth\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal vent to mantel\u003c\/td\u003e\n\u003ctd\u003e2\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop of unit to mantel, snorkel termination\u003c\/td\u003e\n\u003ctd\u003e16\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe manual specifies the 4\" corner clearance measured from the edge of the firebox to the adjacent wall. The 2\" horizontal-vent-to-mantel dimension is a separate vent clearance and is not the same requirement as the 2\" appliance side clearance. Vent component clearances, the vent manufacturer's own instructions and local code requirements apply in addition to the appliance clearances above, and where a vent clearance is larger at the same point it governs.\u003c\/p\u003e\n\u003cp\u003eFloor protection requirements are as follows.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFloor surface\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoncombustible surface\u003c\/td\u003e\n\u003ctd\u003eThe appliance may be placed directly on the surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWood floor\u003c\/td\u003e\n\u003ctd\u003eThe appliance may be placed directly on the floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther combustible surface\u003c\/td\u003e\n\u003ctd\u003eInstall a panel of metal, wood, stone or glass under the appliance, extending the full width and the full depth of the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual states that luxury vinyl plank and luxury vinyl tile flooring begins to warp at 110 degrees Fahrenheit, and that the minimum required clearance from the front glass of the stove to LVP or LVT flooring is 6\". Maintain that 6\" minimum and check the flooring manufacturer's temperature limits with your installer before installing over vinyl flooring.\u003c\/p\u003e\n\u003ch3\u003eDirect Vent Requirements\u003c\/h3\u003e\n\u003cp\u003eThe Champlain uses a 4\" × 6-5\/8\" direct vent system connected at 45° at the appliance. It may not be vented into a shared vent system. The planning limits below come from the current Model 8304 manual; the manual's complete venting instructions, its vent termination clearance figure and its venting chart govern the actual installation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting limit\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system height without offsets\u003c\/td\u003e\n\u003ctd\u003e40 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum offset\u003c\/td\u003e\n\u003ctd\u003e14 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum rise to run\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum vertical rise, horizontal termination\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal sections\u003c\/td\u003e\n\u003ctd\u003e1\/4\" of rise for every 12\" of horizontal run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEach 90° elbow after the second\u003c\/td\u003e\n\u003ctd\u003eSubtract 5 ft from the allowable horizontal run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSnorkel termination\u003c\/td\u003e\n\u003ctd\u003e45\" maximum horizontal run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall pass-through\u003c\/td\u003e\n\u003ctd\u003eMinimum 10\" × 10\" framed opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall thickness adjustment range\u003c\/td\u003e\n\u003ctd\u003e3\" minimum to 9\" maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum pipe insertion into the horizontal cap\u003c\/td\u003e\n\u003ctd\u003e1-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared vent\u003c\/td\u003e\n\u003ctd\u003eNot permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRoof pitch\u003c\/th\u003e\n\u003cth\u003eMinimum vent height above the roof\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlat to 6\/12\u003c\/td\u003e\n\u003ctd\u003e1 ft (0.3 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\/12 to 9\/12\u003c\/td\u003e\n\u003ctd\u003e2 ft (0.6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\/12 to 12\/12\u003c\/td\u003e\n\u003ctd\u003e4 ft (1.2 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\/12 to 16\/12\u003c\/td\u003e\n\u003ctd\u003e6 ft (1.8 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e17\/12 to 21\/12\u003c\/td\u003e\n\u003ctd\u003e8 ft (2.4 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eVent termination clearances to windows, doors, soffits, corners, grade, decks, gas meters and regulators, air inlets and public walkways are published as a lettered figure in the current manual, with separate United States and Canada values for several of them. The manual also sets the restrictor plate position by vent configuration; this is an installer setting made at installation. Your HearthStone installer will select the vent components, the vent configuration, the restrictor setting and the termination location for your home.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChamplain 8304 gas-fired direct vent heater\u003c\/li\u003e\n\u003cli\u003ePan burner\u003c\/li\u003e\n\u003cli\u003eOwner's packet (manual and warranty card)\u003c\/li\u003e\n\u003cli\u003eLP conversion kit (93-56041)\u003c\/li\u003e\n\u003cli\u003eSix decorative ceramic logs, in a separate box\u003c\/li\u003e\n\u003cli\u003eBag of Platinum Bright Embers\u003c\/li\u003e\n\u003cli\u003eSafety barrier screen (integral)\u003c\/li\u003e\n\u003cli\u003eCast-iron heat exchanger (integral)\u003c\/li\u003e\n\u003cli\u003eSIT 820 Nova gas control system (integral)\u003c\/li\u003e\n\u003cli\u003eRestrictor plate (integral)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVent pipe, vent components and termination kits are supplied separately and are selected for the specific installation. A convection blower and a remote control are not included. The appliance can be operated from its own ON \/ OFF \/ T-STAT switch, from a wall thermostat, or from an optional remote control kit; confirm current thermostat supply with Cozy Glow Stoves. Inspect the appliance and all parts on delivery and contact your dealer immediately if anything is damaged or missing.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvection Blower\u003c\/td\u003e\n\u003ctd\u003e93-57020\u003c\/td\u003e\n\u003ctd\u003e$949\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately. Not included with the appliance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostatic Remote Control\u003c\/td\u003e\n\u003ctd\u003e90-56914\u003c\/td\u003e\n\u003ctd\u003e$229\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately. Named in the current manual as the optional remote control kit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Thermostatic Remote Control\u003c\/td\u003e\n\u003ctd\u003e90-56917\u003c\/td\u003e\n\u003ctd\u003e$399\u003c\/td\u003e\n\u003ctd\u003eOptional; sold separately. Listed for Model 8304 on HearthStone's current dealer pricing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese are the accessories listed for Model 8304 in HearthStone's current dealer pricing and on HearthStone's current Champlain product information. The included LP conversion kit is supplied with the appliance and is not a separately purchased accessory. Contact Cozy Glow Stoves for current availability and for vent components.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Champlain is covered by HearthStone's limited manufacturer warranty as printed in the current Model 8304 owner's manual, which defines its Limited Lifetime coverage as 10 years from the beginning of warranty coverage. For gas appliances the manual's warranty table covers stone, cast iron not listed elsewhere and the clean burning air supply system under Limited Lifetime; door handles and latches, steel components and firebox, and burner and logs for 5 years; appliance electrical and gas components and refractory, vermiculite panels and baffles for 2 years; and enamel finish against peeling or fading, accessories, glass and all components not listed elsewhere for 1 year. Warranty labor is covered during the first year only, at HearthStone's published labor rates, and only where the appliance was installed by an authorized dealer or their designated representative. The manual states that online registration is not required as a condition of warranty coverage. Coverage applies only to components present on this appliance. Exclusions, eligibility and claim requirements are governed by the warranty as printed in the manual supplied with the appliance. Retain your proof of purchase.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built wood and gas hearth appliances for more than four decades. The Champlain 8304 is part of HearthStone's current direct vent gas stove range, all of which use a cast-iron heat exchanger.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the Champlain 8304, current pricing, fuel configuration and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53734830866708,"sku":"8304","price":4499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Champlain8302_matteblack.webp?v=1787794445"},{"product_id":"hearthstone-stoves-stowe-8325-direct-vent-gas-stove","title":"Hearthstone Stoves Stowe 8325 Direct Vent Gas Stove","description":"\u003ch2\u003eCompact Cast-Iron Direct Vent Gas Heat with an 80.1% Steady State Efficiency\u003c\/h2\u003e\n\u003cp\u003eThe Stowe (Model 8325) is a compact freestanding direct vent gas stove with an enameled or painted cast-iron body, a ceramic burner and a maximum input of 22,400 BTU\/hr.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIT 820 Nova millivolt control system\u003c\/strong\u003e with a standing pilot and a 7-day pilot timeout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e22,400 BTU\/hr maximum input\u003c\/strong\u003e at 0 to 2,000 ft on natural gas or propane, with a 15,000 BTU\/hr minimum input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e80.1% Steady State Efficiency\u003c\/strong\u003e and 75.7% P.4.1.09 Efficiency as published for Model 8325\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats up to 1,200 sq. ft.\u003c\/strong\u003e, depending on installation and operating conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShips configured for natural gas\u003c\/strong\u003e with an LP conversion kit included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral cast-iron heat exchanger\u003c\/strong\u003e and integral safety barrier screen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\" x 6-5\/8\" direct vent\u003c\/strong\u003e with a 45-degree appliance outlet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved for mobile home installation\u003c\/strong\u003e in the United States and certified for Canada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour finishes\u003c\/strong\u003e: Matte Black, Brown Enamel, Oyster Enamel and Basil Enamel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eSIT 820 Nova Control with 7-Day Pilot Timeout\u003c\/h4\u003e\n\u003cp\u003eThe Stowe uses a SIT 820 valve system. The pilot is a standing pilot lit with the stove's own piezoelectric spark igniter, and the thermopile generates the millivolt supply that powers the gas control valve, so the appliance itself does not depend on household current to operate. The gas valve extinguishes the pilot after 7 days without a call for heat. HearthStone notes in the owner's manual that where the stove is left idle outside peak heating season, a programmable thermostat set to run the stove at least once a week will keep the pilot from timing out.\u003c\/p\u003e\n\u003ch4\u003eManual, Thermostat or Optional Remote Operation\u003c\/h4\u003e\n\u003cp\u003eThe Stowe can be run manually at the gas control valve, with a wall-mounted 750 millivolt thermostat, or with the optional SIT remote control kit. A variable output control on the gas valve adjusts heat output between the published minimum and maximum inputs, so a low flame setting gives longer burn cycles at reduced output and a high setting gives a shorter, hotter cycle.\u003c\/p\u003e\n\u003ch4\u003eCeramic Burner, Five-Piece Log Set and Platinum Bright Embers\u003c\/h4\u003e\n\u003cp\u003eModel 8325 is published with a ceramic burner. The stove ships with a five-piece decorative ceramic log set packed separately and a bag of Platinum Bright Embers, both installed in a specified sequence during setup.\u003c\/p\u003e\n\u003ch4\u003eIntegral Cast-Iron Heat Exchanger\u003c\/h4\u003e\n\u003cp\u003eA cast-iron heat exchanger sits above the fire and is integral to the appliance. HearthStone describes its purpose as moving heat from the fire into the room rather than up the chimney.\u003c\/p\u003e\n\u003ch4\u003eIntegral Safety Barrier Screen\u003c\/h4\u003e\n\u003cp\u003eThe Stowe includes a safety barrier screen as an integral part of the appliance. The owner's manual lists the safety barrier screen among the Model 8325 features, and the current specification sheet lists safety barrier screens as included.\u003c\/p\u003e\n\u003ch4\u003eNatural Gas as Shipped, Propane with the Included Kit\u003c\/h4\u003e\n\u003cp\u003eThe Stowe is factory equipped to burn natural gas. A propane conversion kit is included with the appliance and must be installed by qualified service personnel before the stove is operated on propane. At elevations from 0 to 2,000 ft, maximum input is 22,400 BTU\/hr on either natural gas or propane, with a 15,000 BTU\/hr minimum input. For installations from 2,000 to 4,500 ft, current Model 8325 technical data specifies a 21,000 BTU\/hr maximum input on natural gas while propane remains rated at 22,400 BTU\/hr. Natural-gas installations above 2,000 ft require the manufacturer's high-altitude conversion procedure.\u003c\/p\u003e\n\u003ch4\u003eOptional Blower and Optional Remote\u003c\/h4\u003e\n\u003cp\u003eA convection blower and a remote control kit are both optional on Model 8325 and are sold separately. Neither is included with the appliance. The optional blower is a variable speed unit and requires household current; the appliance itself operates on its own millivolt system.\u003c\/p\u003e\n\u003ch4\u003eDirect Vent Installation\u003c\/h4\u003e\n\u003cp\u003eThe Stowe is a direct vent appliance using a 4\" x 6-5\/8\" vent with a 45-degree outlet at the stove. HearthStone approves three venting configurations for this model: vertical venting with vertical termination, vertical venting with horizontal termination, and horizontal venting with snorkel termination. Vent components must come from an approved manufacturer and must not be mixed between manufacturers within the same system.\u003c\/p\u003e\n\u003ch4\u003eApproved for Mobile Home Installation\u003c\/h4\u003e\n\u003cp\u003eModel 8325 is approved for installation in an aftermarket, permanently located manufactured home in the United States where not prohibited by local codes, and the rating plate is marked certified for mobile home installation. The rating plate is also marked certified for Canada.\u003c\/p\u003e\n\u003ch4\u003eBuilt in Vermont\u003c\/h4\u003e\n\u003cp\u003eThe Model 8325 rating plate identifies the appliance as manufactured by HearthStone QHHP, Inc. of Morrisville, Vermont, and the current HearthStone catalog describes its direct vent gas stoves as certified gas-fired direct vent heaters made in Vermont.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eAll four configurations are the same Model 8325 appliance and differ only in exterior finish. Each ships configured for natural gas with an LP conversion kit included.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eFuel configuration\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eIncluded equipment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatte Black\u003c\/td\u003e\n\u003ctd\u003e8325-0010NP\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas\u003c\/td\u003e\n\u003ctd\u003e$4,149\u003c\/td\u003e\n\u003ctd\u003eLP conversion kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8325-0020NP\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas\u003c\/td\u003e\n\u003ctd\u003e$4,449\u003c\/td\u003e\n\u003ctd\u003eLP conversion kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasil Enamel\u003c\/td\u003e\n\u003ctd\u003e8325-0083NP\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas\u003c\/td\u003e\n\u003ctd\u003e$4,449\u003c\/td\u003e\n\u003ctd\u003eLP conversion kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOyster Enamel\u003c\/td\u003e\n\u003ctd\u003e8325-0031NP\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas\u003c\/td\u003e\n\u003ctd\u003e$4,999\u003c\/td\u003e\n\u003ctd\u003eLP conversion kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePlease contact us to confirm current finish availability and lead time before ordering.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eModel 8325\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003e8325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed as\u003c\/td\u003e\n\u003ctd\u003eDirect Vent Gas Room Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input, natural gas, 0 to 2,000 ft\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input, propane, 0 to 2,000 ft\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input, natural gas, 2,000 to 4,500 ft\u003c\/td\u003e\n\u003ctd\u003e21,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input, propane, 2,000 to 4,500 ft\u003c\/td\u003e\n\u003ctd\u003e22,400 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum input, natural gas\u003c\/td\u003e\n\u003ctd\u003e15,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum input, propane\u003c\/td\u003e\n\u003ctd\u003e15,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating area\u003c\/td\u003e\n\u003ctd\u003eUp to 1,200 sq. ft., depending on installation and operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Efficiency\u003c\/td\u003e\n\u003ctd\u003e80.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP.4.1.09 Efficiency\u003c\/td\u003e\n\u003ctd\u003e75.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel as shipped\u003c\/td\u003e\n\u003ctd\u003eNatural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePropane conversion\u003c\/td\u003e\n\u003ctd\u003eConversion kit included with the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl system\u003c\/td\u003e\n\u003ctd\u003eSIT 820 Nova millivolt system, standing pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot timeout\u003c\/td\u003e\n\u003ctd\u003e7 days of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot ignition\u003c\/td\u003e\n\u003ctd\u003ePiezoelectric spark igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurner\u003c\/td\u003e\n\u003ctd\u003eCeramic Burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog set\u003c\/td\u003e\n\u003ctd\u003eFive-piece decorative ceramic log set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmber media\u003c\/td\u003e\n\u003ctd\u003ePlatinum Bright Embers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger\u003c\/td\u003e\n\u003ctd\u003eIntegral cast-iron heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety barrier\u003c\/td\u003e\n\u003ctd\u003eIntegral safety barrier screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior\u003c\/td\u003e\n\u003ctd\u003eEnameled or painted cast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent size\u003c\/td\u003e\n\u003ctd\u003e4\" x 6-5\/8\" direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent outlet\u003c\/td\u003e\n\u003ctd\u003e45-degree outlet at the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas connection\u003c\/td\u003e\n\u003ctd\u003e3\/8\" male NPT at the gas control valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvection blower\u003c\/td\u003e\n\u003ctd\u003eOptional, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003ctd\u003eOptional, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile home installation\u003c\/td\u003e\n\u003ctd\u003eApproved, United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003eCertified for Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.88-2017 \/ CSA 2.33-2017, CSA 2.17-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFS File\u003c\/td\u003e\n\u003ctd\u003e#20-640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting agency\u003c\/td\u003e\n\u003ctd\u003eIntertek Testing Services NA, Inc. (ITS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing agency\u003c\/td\u003e\n\u003ctd\u003ePFS Teco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e155 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e22-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e18-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight to center of rear vent exit\u003c\/td\u003e\n\u003ctd\u003e22-3\/4\", shown with 45-degree elbow venting; dimensions may vary depending on venting manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eEquipped for use at 0 to 2,000 ft. Natural gas installations from 2,000 to 4,500 ft must be de-rated using the manufacturer's high-altitude conversion procedure; propane does not require de-rating through 4,500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePublished dimensions describe the appliance body. Overall installed dimensions that include the vent depend on the venting arrangement and the vent manufacturer.\u003c\/p\u003e\n\u003ch3\u003eClearances and Installation\u003c\/h3\u003e\n\u003cp\u003eThe values below are minimum clearances to combustibles for the appliance as published for Model 8325. They are minimum distances in all cases. The installer is responsible for assessing the combustible materials in the actual installation, and the installation must also meet local codes and the requirements of the gas supplier.\u003c\/p\u003e\n\u003ch4\u003eAppliance Clearances to Combustibles\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003cth\u003eMinimum clearance\u003c\/th\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit to rear wall\u003c\/td\u003e\n\u003ctd\u003e3\" (77 mm)\u003c\/td\u003e\n\u003ctd\u003eAppliance rear clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit to side walls\u003c\/td\u003e\n\u003ctd\u003e4\" (102 mm)\u003c\/td\u003e\n\u003ctd\u003eWhere the side wall is 18\" deep or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit to side walls\u003c\/td\u003e\n\u003ctd\u003e6\" (153 mm)\u003c\/td\u003e\n\u003ctd\u003eWhere the side wall is deeper than 18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorner to adjacent wall\u003c\/td\u003e\n\u003ctd\u003e4\" (102 mm)\u003c\/td\u003e\n\u003ctd\u003eCorner installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe side clearance is conditional. A side wall 18\" deep or less requires 4\". A side wall deeper than 18\" requires 6\". Confirm the actual side wall depth before siting the stove.\u003c\/p\u003e\n\u003cp\u003eHearthStone also notes that the governing rear clearance is set by either the appliance's minimum clearance or the vent pipe's minimum clearance, depending on whether the installation uses vertical rise within the room or a rear exit through-the-wall vent. Allow for access to the gas control valve access door on the front of the unit, for periodic cleaning and servicing, and for the blower assembly if one is present or planned.\u003c\/p\u003e\n\u003ch4\u003eMantel Clearances\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel depth\u003c\/td\u003e\n\u003ctd\u003e17\" (432 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal vent to mantel\u003c\/td\u003e\n\u003ctd\u003e2\" (51 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSnorkel termination, top of unit to mantel\u003c\/td\u003e\n\u003ctd\u003e15\" (381 mm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eVent Pipe Clearances to Combustibles\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVent run\u003c\/th\u003e\n\u003cth\u003eMinimum clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical runs\u003c\/td\u003e\n\u003ctd\u003e1\" to all sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal runs, below and to the side\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal runs, above\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eHearth and Floor Protection\u003c\/h4\u003e\n\u003cp\u003eThe Stowe may be placed directly on any non-combustible surface or on a wood floor. On any other combustible surface a panel of metal, wood, stone or glass must be installed under the appliance, extending the full width and depth of the appliance. Installations must meet all local codes.\u003c\/p\u003e\n\u003cp\u003eWhere the stove is installed in a room with luxury vinyl plank or luxury vinyl tile flooring, the minimum required clearance from the front glass of the stove to the LVP or LVT flooring is 6\". HearthStone notes that LVP and LVT flooring begins to warp at 110 degrees Fahrenheit.\u003c\/p\u003e\n\u003ch4\u003eVenting Requirements\u003c\/h4\u003e\n\u003cp\u003eThree venting configurations are approved for Model 8325: vertical venting with vertical termination, vertical venting with horizontal termination, and horizontal venting with snorkel termination.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical termination\u003c\/strong\u003e requires at least 10 ft of vertical pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum vertical run\u003c\/strong\u003e is 35 ft, and the maximum length of vent in a chimney installation is 35 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElbows in vertical terminations\u003c\/strong\u003e are limited to a maximum of two 90-degree or four 45-degree elbows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal venting\u003c\/strong\u003e requires a minimum 9\" rise, taken either directly off the heater or with a minimum 14\" snorkel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal sections\u003c\/strong\u003e require a 1\/4\" rise every 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAt minimum vertical rise\u003c\/strong\u003e, the maximum horizontal run is 10 ft. A maximum horizontal run of 10 ft also applies where a 14\" snorkel termination is used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor each 90-degree elbow after the second\u003c\/strong\u003e, remove 5 ft from the allowable horizontal run. For Canadian installations, remove 4 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall penetrations\u003c\/strong\u003e require a minimum 10\" x 10\" square hole, with the vent positioned to maintain 2\" minimum clearance at the top and 1\" minimum clearance on the other sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination caps\u003c\/strong\u003e must be no less than 18\" horizontally from any roof or vertical surface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVent and air intake termination clearances above the high side of an angled roof are published as follows.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRoof pitch\u003c\/th\u003e\n\u003cth\u003eMinimum clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlat to 6\/12\u003c\/td\u003e\n\u003ctd\u003e1 ft (0.3 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\/12 to 9\/12\u003c\/td\u003e\n\u003ctd\u003e2 ft (0.6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\/12 to 12\/12\u003c\/td\u003e\n\u003ctd\u003e4 ft (1.2 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\/12 to 16\/12\u003c\/td\u003e\n\u003ctd\u003e6 ft (1.8 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e17\/12 to 21\/12\u003c\/td\u003e\n\u003ctd\u003e8 ft (2.4 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eVent terminal locations are further governed by the acceptable termination location requirements published for this model, which set separate minimum distances to grade, windows and doors, soffits, corners, gas meters and regulators, air supply inlets, sidewalks and decks, and which differ between United States and Canadian installations. Review these with your installer before selecting a termination point.\u003c\/p\u003e\n\u003cp\u003eVent kits and components are supplied separately. Only venting components from the manufacturers approved by HearthStone for this appliance may be used, and components from different manufacturers must not be mixed within the same venting system.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cp\u003eThe Model 8325 packing list specifies the following.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 Stowe 8325 gas-fired heater\u003c\/li\u003e\n\u003cli\u003e1 Pan Burner\u003c\/li\u003e\n\u003cli\u003e1 Owner's Packet, containing the manual and warranty card\u003c\/li\u003e\n\u003cli\u003e1 LP Conversion Kit\u003c\/li\u003e\n\u003cli\u003e5 Decorative Ceramic Logs, in a separate box\u003c\/li\u003e\n\u003cli\u003e1 Bag of Platinum Bright Embers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe safety barrier screen and the cast-iron heat exchanger are integral to the appliance. Vent kits and vent components are supplied separately and are not included with the stove. A convection blower and a remote control kit are optional and are not included.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower: Stowe\u003c\/td\u003e\n\u003ctd\u003e93-57230\u003c\/td\u003e\n\u003ctd\u003e$949\u003c\/td\u003e\n\u003ctd\u003eOptional convection blower. Sold Separately. Requires household current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Control Kit, SIT\u003c\/td\u003e\n\u003ctd\u003e90-56914\u003c\/td\u003e\n\u003ctd\u003e$229\u003c\/td\u003e\n\u003ctd\u003eOptional thermostatic remote control. Sold Separately. Listed for 8324 and 8325 models only.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAccessory availability and pricing are current as published by HearthStone and may change. Contact us to confirm before ordering.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Stowe is covered by HearthStone's limited manufacturer warranty as printed in the current Model 8325 owner's manual, which defines its Limited Lifetime coverage as 10 years from the beginning of warranty coverage. For gas appliances the manual's warranty table covers stone and cast iron not listed elsewhere under Limited Lifetime; door handles and latches, steel components and firebox, and burner and logs for 5 years; appliance electrical and gas components and refractory, vermiculite panels and baffles for 2 years; and enamel finish against peeling or fading, accessories, glass and all components not listed elsewhere for 1 year. Warranty labor is covered during the first year only, and only where the appliance was installed by an authorized dealer or their designated representative. The warranty extends to the original retail purchaser and is not transferrable. The manual notes that online registration is not required as a condition of warranty coverage. Coverage applies only to components present on this appliance. Exclusions, eligibility and claim requirements are governed by the warranty as printed in the manual supplied with the appliance. Retain your proof of purchase.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built wood and gas hearth appliances for more than four decades. The Stowe 8325 is part of HearthStone's current direct vent gas stove range, all of which use a cast-iron heat exchanger.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the Stowe 8325, current pricing, finish availability, fuel configuration and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53896618344724,"sku":"8325","price":4149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Stowe8323_matteblack.webp?v=1788102096"},{"product_id":"hearthstone-stoves-waitsfield-8771-direct-vent-gas-stove","title":"Hearthstone Stoves Waitsfield 8771 Direct Vent Gas Stove","description":"\u003ch2\u003eThree-Sided Cast-Iron Direct Vent Gas Heat for Rooms Up to 1,800 Sq. Ft.\u003c\/h2\u003e\n\u003cp\u003eThe Waitsfield (Model 8771) is a freestanding direct vent gas stove with an enameled or painted cast-iron body, a steel pan burner and a maximum input of 33,000 BTU\/hr.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIT Nova 821 millivolt gas control\u003c\/strong\u003e with a 7-day pilot timeout and a battery-powered continuous sparker for pilot ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e32,500 BTU\/hr maximum input on natural gas and 33,000 BTU\/hr on propane\u003c\/strong\u003e, with a 17,500 BTU\/hr natural gas and 18,500 BTU\/hr propane minimum input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats up to 1,800 sq. ft.\u003c\/strong\u003e, depending on installation and operating conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e72.8% Steady State Efficiency on natural gas and 74.5% on propane\u003c\/strong\u003e as published for Model 8771\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShips configured for natural gas\u003c\/strong\u003e with an LP conversion kit included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteel pan burner with a five-piece ceramic log set\u003c\/strong\u003e, Platinum Bright Embers and ceramic nuggets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral cast-iron heat exchanger\u003c\/strong\u003e and integral safety barrier screen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\" x 6-5\/8\" direct vent\u003c\/strong\u003e with a top outlet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved for mobile home installation\u003c\/strong\u003e in the United States and certified for Canada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree finishes\u003c\/strong\u003e: Matte Black, Brown Enamel and Basil Enamel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eSIT Nova 821 Millivolt Control with 7-Day Pilot Timeout\u003c\/h4\u003e\n\u003cp\u003eThe Waitsfield uses a SIT Nova 821 gas control valve. The thermopile generates the millivolt supply that powers the valve, so the appliance itself does not depend on household current to operate. HearthStone specifies a thermopile output of 325 to 500 millivolts. The valve extinguishes the pilot after 7 days without a call for heat, a feature HearthStone describes as meeting the requirements of states and municipalities that do not permit continuously burning pilots. The owner's manual warns that the timer system must not be defeated or modified.\u003c\/p\u003e\n\u003ch4\u003eBattery-Powered Continuous Sparker for Pilot Ignition\u003c\/h4\u003e\n\u003cp\u003eThe pilot is lit by a continuous spark igniter connected to the pilot assembly, powered by a single AA battery housed in a sparker box mounted below the stove. The spark begins as the gas control knob is pressed in at the pilot position. HearthStone directs that the appliance must not be lit by a match or by any means other than the supplied ignition system, and recommends replacing the battery each season.\u003c\/p\u003e\n\u003ch4\u003eManual, Thermostat or Optional Remote Operation\u003c\/h4\u003e\n\u003cp\u003eThe Waitsfield can be run manually at the gas control valve, with a wall-mounted 750 millivolt thermostat, or with an optional remote control kit. The thermostat is not supplied with the appliance. A variable output control on the gas valve adjusts heat output between the published minimum and maximum inputs, so a low flame setting gives longer burn cycles at reduced output and a high setting gives a shorter, hotter cycle.\u003c\/p\u003e\n\u003ch4\u003eSteel Pan Burner, Five-Piece Log Set and Ember Media\u003c\/h4\u003e\n\u003cp\u003eModel 8771 is published with a steel pan burner. The stove ships with a five-piece decorative ceramic log set packed separately, a bag of Platinum Bright Embers and a bag of ceramic nuggets. The manual specifies an exact log and ember placement sequence, which is required for a correct flame pattern and clean combustion.\u003c\/p\u003e\n\u003ch4\u003eIntegral Cast-Iron Heat Exchanger\u003c\/h4\u003e\n\u003cp\u003eA cast-iron heat exchanger is integral to the appliance. HearthStone describes its purpose as moving heat from the fire into the room rather than up the chimney.\u003c\/p\u003e\n\u003ch4\u003eIntegral Safety Barrier Screen\u003c\/h4\u003e\n\u003cp\u003eThe Waitsfield includes a safety barrier screen as an integral part of the appliance. The screens are mechanically affixed to the inside surface of the front and side castings, and HearthStone requires that a damaged barrier be replaced with the manufacturer's barrier for this appliance before the stove is operated.\u003c\/p\u003e\n\u003ch4\u003eNatural Gas as Shipped, Propane with the Included Kit\u003c\/h4\u003e\n\u003cp\u003eThe Waitsfield is factory equipped to burn natural gas. A propane conversion kit is included with the appliance and must be installed by qualified service personnel before the stove is operated on propane. Maximum input is 32,500 BTU\/hr on natural gas and 33,000 BTU\/hr on propane, with minimum inputs of 17,500 BTU\/hr and 18,500 BTU\/hr respectively. The Model 8771 rating label publishes the same maximum ratings at 0 to 2,000 ft and at 2,000 to 4,500 ft, and the manual states that the de-rating gas suppliers typically apply above 2,000 ft is not necessary with the Waitsfield.\u003c\/p\u003e\n\u003ch4\u003eOptional Blower and Optional Remote\u003c\/h4\u003e\n\u003cp\u003eA convection blower and two remote control options are optional on Model 8771 and are sold separately. None of them is included with the appliance. The blower mounts below the stove, is switched on automatically by a snap switch once the stove body reaches temperature, and is speed-adjusted with a rheostat. The blower requires household current; the appliance itself operates on its own millivolt system.\u003c\/p\u003e\n\u003ch4\u003eDirect Vent Installation\u003c\/h4\u003e\n\u003cp\u003eThe Waitsfield is a direct vent appliance using a 4\" x 6-5\/8\" vent with a top outlet at the stove. HearthStone approves two venting configurations for this model: vertical venting with vertical termination, and vertical venting with horizontal termination. Vent components must come from an approved manufacturer and must not be mixed between manufacturers within the same venting system.\u003c\/p\u003e\n\u003ch4\u003eApproved for Mobile Home Installation\u003c\/h4\u003e\n\u003cp\u003eModel 8771 is approved for installation in an aftermarket, permanently located manufactured home in the United States where not prohibited by local codes, and the rating label is marked certified for mobile home installation. The rating label is also marked certified for Canada.\u003c\/p\u003e\n\u003ch4\u003eMade in the USA\u003c\/h4\u003e\n\u003cp\u003eThe Model 8771 rating label identifies HearthStone QHHP, Inc. of Morrisville, Vermont as the manufacturer and is marked Made in USA.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eAll three configurations are the same Model 8771 appliance and differ only in exterior finish. Each ships configured for natural gas with an LP conversion kit included.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eFuel configuration\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eIncluded equipment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatte Black\u003c\/td\u003e\n\u003ctd\u003e8771-0010\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas\u003c\/td\u003e\n\u003ctd\u003e$5,399\u003c\/td\u003e\n\u003ctd\u003eLP conversion kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8771-0020\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas\u003c\/td\u003e\n\u003ctd\u003e$6,249\u003c\/td\u003e\n\u003ctd\u003eLP conversion kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasil Enamel\u003c\/td\u003e\n\u003ctd\u003e8771-0083\u003c\/td\u003e\n\u003ctd\u003eShips as natural gas\u003c\/td\u003e\n\u003ctd\u003e$6,249\u003c\/td\u003e\n\u003ctd\u003eLP conversion kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePlease contact us to confirm current finish availability and lead time before ordering.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eModel 8771\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eFreestanding direct vent gas stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003e8771\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed as\u003c\/td\u003e\n\u003ctd\u003eDirect Vent Gas Room Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input, natural gas, 0 to 2,000 ft\u003c\/td\u003e\n\u003ctd\u003e32,500 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input, propane, 0 to 2,000 ft\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input, natural gas, 2,000 to 4,500 ft\u003c\/td\u003e\n\u003ctd\u003e32,500 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input, propane, 2,000 to 4,500 ft\u003c\/td\u003e\n\u003ctd\u003e33,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum input, natural gas\u003c\/td\u003e\n\u003ctd\u003e17,500 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum input, propane\u003c\/td\u003e\n\u003ctd\u003e18,500 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating area\u003c\/td\u003e\n\u003ctd\u003eUp to 1,800 sq. ft., depending on installation and operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Efficiency\u003c\/td\u003e\n\u003ctd\u003e72.8% natural gas, 74.5% propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP.4.1.09 Efficiency\u003c\/td\u003e\n\u003ctd\u003e66.5% natural gas, 67.5% propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel as shipped\u003c\/td\u003e\n\u003ctd\u003eNatural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePropane conversion\u003c\/td\u003e\n\u003ctd\u003eConversion kit included with the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl system\u003c\/td\u003e\n\u003ctd\u003eSIT Nova 821 millivolt gas control valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot ignition\u003c\/td\u003e\n\u003ctd\u003eBattery-powered continuous sparker, one AA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot timeout\u003c\/td\u003e\n\u003ctd\u003e7 days of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermopile output\u003c\/td\u003e\n\u003ctd\u003e325 to 500 millivolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat output control\u003c\/td\u003e\n\u003ctd\u003eVariable output control at the gas valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurner\u003c\/td\u003e\n\u003ctd\u003eSteel pan burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog set\u003c\/td\u003e\n\u003ctd\u003eFive-piece decorative ceramic log set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmber media\u003c\/td\u003e\n\u003ctd\u003ePlatinum Bright Embers and ceramic nuggets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger\u003c\/td\u003e\n\u003ctd\u003eIntegral cast-iron heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety barrier\u003c\/td\u003e\n\u003ctd\u003eIntegral safety barrier screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior\u003c\/td\u003e\n\u003ctd\u003eEnameled or painted cast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent size\u003c\/td\u003e\n\u003ctd\u003e4\" x 6-5\/8\" direct vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent outlet\u003c\/td\u003e\n\u003ctd\u003eTop outlet at the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas connection\u003c\/td\u003e\n\u003ctd\u003e3\/8\" male NPT at the gas control valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas supply line\u003c\/td\u003e\n\u003ctd\u003e1\/2\" diameter recommended, or as appropriately sized, subject to local codes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical rating\u003c\/td\u003e\n\u003ctd\u003e120 volts, 60 Hz, 15 A. Required only for the optional blower; the appliance operates on its own millivolt system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvection blower\u003c\/td\u003e\n\u003ctd\u003eOptional, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003ctd\u003eOptional, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall thermostat\u003c\/td\u003e\n\u003ctd\u003e750 millivolt wall thermostat supported, not supplied with the appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile home installation\u003c\/td\u003e\n\u003ctd\u003eApproved, United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003ctd\u003eCertified for Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.88-2019 \/ CSA 2.33-2019, CSA 2.17-17, CSA P.4.1-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFS File\u003c\/td\u003e\n\u003ctd\u003e#22-831\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting agency\u003c\/td\u003e\n\u003ctd\u003ePFS TECO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing agency\u003c\/td\u003e\n\u003ctd\u003ePFS TECO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e215 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e21-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e26-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eThe rating label publishes the same input ratings and the same orifice sizes at 0 to 2,000 ft and at 2,000 to 4,500 ft. The manual states that the de-rating gas suppliers typically apply above 2,000 ft is not necessary with the Waitsfield.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePublished dimensions describe the appliance body. Overall installed dimensions that include the vent depend on the venting arrangement and the vent manufacturer.\u003c\/p\u003e\n\u003ch3\u003eClearances and Floor Protection\u003c\/h3\u003e\n\u003cp\u003eThe values below are minimum clearances to combustibles published for Model 8771. They are minimum distances in all cases. The installer is responsible for assessing the combustible materials in the actual installation, and the installation must also meet local codes and the requirements of the gas supplier.\u003c\/p\u003e\n\u003ch4\u003eAppliance Clearances to Combustibles\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003cth\u003eMinimum clearance\u003c\/th\u003e\n\u003cth\u003eMeasured from\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit to rear wall\u003c\/td\u003e\n\u003ctd\u003e2\" (51 mm)\u003c\/td\u003e\n\u003ctd\u003eRear of the appliance at the vent collar housing to the wall surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit to side walls\u003c\/td\u003e\n\u003ctd\u003e16\" (407 mm)\u003c\/td\u003e\n\u003ctd\u003eSide of the stove body to the wall surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorner to adjacent wall\u003c\/td\u003e\n\u003ctd\u003e11\" (280 mm)\u003c\/td\u003e\n\u003ctd\u003eEdge of the top castings to the adjacent wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that the governing rear clearance is set by either the appliance's minimum clearance or the vent pipe's minimum clearance, depending on whether the installation uses vertical rise within the room or a rear exit through-the-wall vent. Allow for access to the gas control valve access door on the front of the unit, for periodic cleaning and servicing, and for the blower assembly if one is present or planned.\u003c\/p\u003e\n\u003ch4\u003eMantel Clearances\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel depth\u003c\/td\u003e\n\u003ctd\u003e17\" (432 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal vent to underside of mantel\u003c\/td\u003e\n\u003ctd\u003e2\" (51 mm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eVent Pipe Clearances to Combustibles\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVent run\u003c\/th\u003e\n\u003cth\u003eMinimum clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical runs\u003c\/td\u003e\n\u003ctd\u003e1\" to all sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal runs, below and to the sides\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal runs, above\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eHearth and Floor Protection\u003c\/h4\u003e\n\u003cp\u003eThe Waitsfield may be placed directly on any non-combustible surface or on a wood floor. On any other combustible surface a panel of metal, wood, stone or glass must be installed under the appliance, extending the full width and depth of the appliance. Installations must meet all local codes.\u003c\/p\u003e\n\u003cp\u003eWhere the stove is installed in a room with luxury vinyl plank or luxury vinyl tile flooring, HearthStone notes that some LVP and LVT flooring begins to warp at 110 degrees Fahrenheit, that each installation and flooring specification is different, and that additional shielding to prevent warping may be necessary depending on the flooring used. HearthStone directs the installer to consult the flooring manufacturer for maximum temperature recommendations. The Model 8771 manual does not publish a numeric stove-to-flooring distance for LVP or LVT.\u003c\/p\u003e\n\u003ch3\u003eDirect Vent Requirements\u003c\/h3\u003e\n\u003cp\u003eTwo venting configurations are approved for Model 8771: vertical venting with vertical termination, and vertical venting with horizontal termination.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical termination\u003c\/strong\u003e requires at least 10 ft of vertical pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum vertical run\u003c\/strong\u003e is 35 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElbows in vertical terminations\u003c\/strong\u003e are limited to a maximum of two 90-degree or four 45-degree elbows, and HearthStone recommends 45-degree elbows wherever possible because they offer less restriction to the flue gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal termination\u003c\/strong\u003e requires a minimum 36\" rise directly off the heater, unless a minimum 14\" snorkel is used, in which case a 24\" vertical rise is required directly off the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum horizontal run\u003c\/strong\u003e is 9\" and the \u003cstrong\u003emaximum horizontal run\u003c\/strong\u003e is 10 ft, provided a 1\/4\" rise is provided for every 12\" of horizontal run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor each 90-degree elbow after the second\u003c\/strong\u003e, remove 5 ft from the allowable horizontal run. For Canadian installations, remove 4 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall penetrations\u003c\/strong\u003e require a minimum 10\" x 10\" square hole, with the vent positioned to maintain 2\" minimum clearance at the top and 1\" minimum clearance to combustible materials around the other sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination caps\u003c\/strong\u003e must be no less than 18\" horizontally from any roof or vertical surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA listed fire stop\u003c\/strong\u003e is required at any floor penetration, framed according to the venting manufacturer's instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVinyl siding\u003c\/strong\u003e requires a vinyl siding stand-off, and the termination cap must not be recessed into the wall or siding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe vent restrictor setting\u003c\/strong\u003e must follow the venting termination chart published in the manual for the vertical rise and horizontal run actually installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVent and air intake termination clearances above the high side of an angled roof are published as follows.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRoof pitch\u003c\/th\u003e\n\u003cth\u003eMinimum clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlat to 6\/12\u003c\/td\u003e\n\u003ctd\u003e1 ft (0.3 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\/12 to 9\/12\u003c\/td\u003e\n\u003ctd\u003e2 ft (0.6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\/12 to 12\/12\u003c\/td\u003e\n\u003ctd\u003e4 ft (1.2 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\/12 to 16\/12\u003c\/td\u003e\n\u003ctd\u003e6 ft (1.8 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e17\/12 to 21\/12\u003c\/td\u003e\n\u003ctd\u003e8 ft (2.4 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eVent Terminal Location Requirements\u003c\/h4\u003e\n\u003cp\u003eTerminal placement is governed by the acceptable direct vent terminal locations published for this model. United States and Canadian requirements differ, and HearthStone publishes recommendations that exceed several of the code minimums. Both are shown below. Review these with your installer before selecting a termination point.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003cth\u003ePublished requirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eClearance above grade, veranda, porch, deck or balcony\u003c\/td\u003e\n\u003ctd\u003e12 inches (30 cm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eClearance to a window or door that may be opened\u003c\/td\u003e\n\u003ctd\u003e9 inches minimum United States, 12 inches (30 cm) Canada. HearthStone recommends 12 inches minimum to prevent condensation on the window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eClearance to a permanently closed window\u003c\/td\u003e\n\u003ctd\u003e9 inches minimum United States, 12 inches (30 cm) Canada. HearthStone recommends 12 inches minimum to prevent condensation on the window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003eVertical clearance to a ventilated soffit located above the termination within a horizontal distance of 2 feet (60 cm) from the center line of the termination\u003c\/td\u003e\n\u003ctd\u003e18 inches (46 cm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eClearance to an unventilated soffit\u003c\/td\u003e\n\u003ctd\u003e12 inches (30 cm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eClearance to an outside corner\u003c\/td\u003e\n\u003ctd\u003e9 inches minimum United States, 12 inches (30 cm) Canada. HearthStone strongly recommends 12 inches, particularly where windy conditions prevail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eClearance to an inside corner\u003c\/td\u003e\n\u003ctd\u003e6 inches minimum United States, 12 inches (30 cm) Canada. HearthStone strongly recommends 12 inches, particularly where strong winds prevail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eClearance to a meter or regulator assembly\u003c\/td\u003e\n\u003ctd\u003eCanada: Not to be installed within 15 feet (4.5 m) above a meter or regulator assembly within 3 feet (91 cm) horizontally from the center line of the regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003ctd\u003eClearance to a service regulator vent\u003c\/td\u003e\n\u003ctd\u003e3 feet (91 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eClearance to a non-mechanical air supply inlet to the building, or to the combustion air inlet of any other appliance\u003c\/td\u003e\n\u003ctd\u003e12 inches (30 cm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003eClearance to a mechanical air supply inlet\u003c\/td\u003e\n\u003ctd\u003eUnited States: 3 feet (91 cm) above if within 10 feet horizontally, minimum. Canada: 6 feet (1.83 m) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eClearance above a paved sidewalk or a paved driveway located on public property\u003c\/td\u003e\n\u003ctd\u003e7 feet (2.1 m) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM\u003c\/td\u003e\n\u003ctd\u003eClearance under a veranda, porch, deck or balcony\u003c\/td\u003e\n\u003ctd\u003e12 inches (30 cm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone publishes the following conditions with the table above. Values marked as United States minimums are in accordance with the current ANSI Z223.1 \/ NFPA 54 National Fuel Gas Code, and local codes and regulations may require different clearances. Values marked for Canada are in accordance with CSA B149 installation codes. A vent must not terminate directly above a sidewalk or driveway which is located between two single family dwellings and serves both dwellings. Clearance M applies only where the veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.\u003c\/p\u003e\n\u003ch4\u003eChimney Installations\u003c\/h4\u003e\n\u003cp\u003eModel 8771 is approved for use with direct vent chimney conversion kits in masonry or prefabricated solid fuel listed chimneys. The termination must fall within the manual's venting termination chart. A masonry chimney must have a fireclay liner or a listed steel liner present for the entire length of the chimney. A prefabricated chimney must be UL103 or ULC S-629 listed, must have a minimum inside diameter of 6\", and must be listed for the specific manufacturer's conversion kit. The maximum vertical length of vent is 35 ft and the liner must have an inside dimension or diameter of 6\" or greater. HearthStone notes that the use of an existing chimney as an air intake is not listed under the ANSI Z21.88 \/ CSA 2.33-2019 test methods, and that this installation has been tested and approved by PFS-TECO Laboratories with an appropriate test; the code authority having jurisdiction must be consulted before proceeding with this installation method.\u003c\/p\u003e\n\u003cp\u003eVent kits and components are supplied separately. Only venting components from the manufacturers approved by HearthStone for this appliance may be used, and components from different manufacturers must not be mixed within the same venting system.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cp\u003eThe Model 8771 packing list specifies the following.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 Waitsfield 8771 gas-fired heater\u003c\/li\u003e\n\u003cli\u003e1 Burner\u003c\/li\u003e\n\u003cli\u003e1 Owner's Packet, containing the manual\u003c\/li\u003e\n\u003cli\u003e1 LP Conversion Kit\u003c\/li\u003e\n\u003cli\u003e1 Decorative Ceramic Log set, in a separate box\u003c\/li\u003e\n\u003cli\u003e1 Bag of Platinum Bright Embers\u003c\/li\u003e\n\u003cli\u003e1 Bag of Ceramic Nuggets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe safety barrier screens, the cast-iron heat exchanger and the SIT Nova 821 gas control system are integral to the appliance. Vent kits and vent components are supplied separately and are not included with the stove. A convection blower and the remote control kits are optional and are not included. A wall thermostat is not supplied with the appliance.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvection Blower\u003c\/td\u003e\n\u003ctd\u003e93-57100\u003c\/td\u003e\n\u003ctd\u003e$499\u003c\/td\u003e\n\u003ctd\u003eOptional convection blower. Sold Separately. Snap-switch activated with rheostat speed control. Requires household current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Remote Control\u003c\/td\u003e\n\u003ctd\u003e90-56917\u003c\/td\u003e\n\u003ctd\u003e$399\u003c\/td\u003e\n\u003ctd\u003eOptional programmable wireless thermostatic control. Sold Separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostatic Remote Control\u003c\/td\u003e\n\u003ctd\u003e90-56914\u003c\/td\u003e\n\u003ctd\u003e$229\u003c\/td\u003e\n\u003ctd\u003eOptional wireless thermostatic control. Sold Separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAccessory availability and pricing are current as published by HearthStone and may change. Contact us to confirm before ordering.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Waitsfield is covered by HearthStone's limited manufacturer warranty as printed in the current Model 8771 owner's manual, which defines its Limited Lifetime coverage as 10 years from the beginning of warranty coverage. For gas appliances the manual's warranty table covers cast iron not listed elsewhere under Limited Lifetime; door handles and latches, steel components and firebox, and burner and logs for 5 years; appliance electrical and gas components and refractory, vermiculite panels and baffles for 2 years; and enamel finish against peeling or fading, accessories, glass and all components not listed elsewhere for 1 year. Warranty labor is covered during the first year only, and only where the appliance was installed by an authorized dealer or their designated representative. The warranty extends to the original retail purchaser and is not transferrable. The manual notes that online registration is not required as a condition of warranty coverage. Coverage applies only to components present on this appliance. Exclusions, eligibility and claim requirements are governed by the warranty as printed in the manual supplied with the appliance. Retain your proof of purchase.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built wood and gas hearth appliances for more than four decades. The Waitsfield 8771 is part of HearthStone's current direct vent gas stove range, all of which use a cast-iron heat exchanger.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the Waitsfield 8771, current pricing, finish availability, fuel configuration and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53918120214804,"sku":"8771","price":5399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Waitsfield8770_matteblack.webp?v=1788137228"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/collections\/HS-LOGO-BLACK.webp?v=1786757717","url":"https:\/\/cozyglowstoves.com\/collections\/hearthstone-stoves.oembed","provider":"Cozy Glow Stoves","version":"1.0","type":"link"}