{"product_id":"hearthstone-stoves-lincoln-freestanding-wood-stove","title":"Hearthstone Stoves Lincoln Freestanding Wood Stove","description":"\u003ch2\u003eA Compact Soapstone Log Burner with TruHybrid™ Catalytic Combustion\u003c\/h2\u003e\n\u003cp\u003eFull soapstone and cast iron construction, TruHybrid™ catalytic combustion, and a 1.0 cubic foot firebox in a 14-inch-wide body designed for small spaces.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 1.14 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e78.5% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003eCompact 14\" wide body sized for cabins, accessory dwelling units, and smaller rooms; heats up to a maximum of 575 square feet\u003c\/li\u003e\n\u003cli\u003e1.0 cubic foot firebox that burns full-size cordwood up to 18\" long, with 16\" recommended\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 9½ hours on a low burn\u003c\/li\u003e\n\u003cli\u003eEnameled square cook plate on the stove top with sliding catalyst access beneath\u003c\/li\u003e\n\u003cli\u003eOptional clip-on side and rear heat shields reduce wall clearances to as little as 9\" at the sides and 3½\" at the rear\u003c\/li\u003e\n\u003cli\u003eApproved for mobile home installation with the required outside air kit, and for alcove installation per the published clearances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe Lincoln 8060 uses HearthStone's TruHybrid™ system, which combines primary and secondary combustion with tertiary combustion through a catalytic combustor. The stainless steel catalytic combustor becomes active at approximately 500°F (260°C) and burns smoke and remaining particles that were not fully consumed in the firebox. A bypass rod routes combustion products around the catalyst during startup and reloading, and a catalyst thermometer indicates when the stove is in the active range. HearthStone states that when the catalyst is active and fully functional, there should be little to no visible smoke from the chimney.\u003c\/p\u003e\n\u003ch4\u003eSoapstone and Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003eFull soapstone and cast iron construction absorbs the high heat of the fire and radiates gentle, long-lasting warmth into the room. Soapstone warms the objects in the room rather than just the air, and HearthStone's cast iron parts are produced at the company's own foundry in Spain. The large glass window allows fire viewing from a variety of locations in the room.\u003c\/p\u003e\n\u003ch4\u003eCompact Log-Burner Design\u003c\/h4\u003e\n\u003cp\u003eThe Lincoln was designed as a traditional log burner that is simple to use, easy to maintain, and sized for small living spaces. It burns full-size cordwood but fits in tight spaces, and HearthStone positions it for cabins, accessory dwelling units, and smaller rooms within a home. Optional heat shields clip onto either side and the back of the stove so it can be placed closer to walls and tucked into corners.\u003c\/p\u003e\n\u003ch4\u003eEnameled Cook Plate and Sliding Catalyst System\u003c\/h4\u003e\n\u003cp\u003eThe square plate on the top of the stove is finished with HearthStone's food-grade enamel, which makes it practical for warming things up and easy to clean. The catalyst rides on a sliding sled: the bypass rod slides it into position once the fire is hot, and the slide system helps you remember to engage the catalyst for a clean burn. With the cook plate removed, the catalyst is accessible for inspection, cleaning, and service.\u003c\/p\u003e\n\u003ch4\u003eEveryday Operation\u003c\/h4\u003e\n\u003cp\u003eA wood-handled front door provides loading access, and a single primary air control lever under the ash lip regulates the burn rate from high to low. The manufacturer-set minimum low burn rate must not be altered. The primary air control, bypass rod, and catalyst thermometer are the stove's operating controls, and fireplace gloves are recommended when the stove is hot.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eThe Lincoln delivers up to 23,000 BTU per hour of maple cordwood and heats up to a maximum of 575 square feet. Factors unique to the home, including insulation value, number and efficiency of windows, floor plan, stove placement, and fuel quality, can reduce the square footage the stove will heat. The stove requires a chimney draft between 0.06\" and 0.1\" water column, verified at installation.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Lincoln 8060 is currently orderable in two finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003e8060-4110\u003c\/td\u003e\n\u003ctd\u003e$2,549\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlue Black\u003c\/td\u003e\n\u003ctd\u003e8060-4159\u003c\/td\u003e\n\u003ctd\u003e$3,049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics FIRECAT stainless steel combustor; replacement part 3050-010 or 3050-020 (two approved alternatives)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalyst activation temperature\u003c\/th\u003e\n\u003ctd\u003eApproximately 500°F (260°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 575 sq ft, depending on home insulation, windows, floor plan, stove placement, fuel quality, and other conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e23,000 BTU per hour of maple cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e14,545 to 20,507 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eUp to 9½ hours on low\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 20 hours, per the current owner's manual (revision 11\/10\/25)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e1.0 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 18\" (45 cm); 16\" (40 cm) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoading\u003c\/th\u003e\n\u003ctd\u003eFront load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDoor glass\u003c\/th\u003e\n\u003ctd\u003eCeramic glass, 9.5\" x 8.7\" (per the current spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e28\" (71.1 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e14\" (35.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e24.5\" (62.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e250 lbs (113.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 40\" x W 29\" x L 36\" (102 x 74 x 92 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter; single-wall connector of 24 MSG or 25 MSG blued steel, or listed double-wall connector (published double-wall clearances are specific to Simpson Dura-Vent DVL and may vary with other brands)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney, 6\" (152 mm) round flue or 8\" x 8\" (203 x 203 mm) square tile; an existing 8\" (203 mm) diameter flue can be used with a reducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended chimney height\u003c\/th\u003e\n\u003ctd\u003eMinimum 16 feet (4.9 m) from the top of the stove; maximum 30 feet (9 m) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; drafts above 0.1\" WC require a stovepipe damper, checked at installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 96-53400 with a minimum 3\" (76 mm) diameter duct supplied by others; adapter 90-53308 is available for 4\" duct; in Canada, outside-air installations require the stove to be attached to the floor and a damper allowing 100% closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved when installed per 24 CFR Part 3280; the outside air kit, permanent floor attachment, a spark arrester, and a listed mobile home chimney and connector kit conforming to UL 103 or CAN\/ULC-S629 are required; not for installation in a sleeping room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlcove installation\u003c\/th\u003e\n\u003ctd\u003eApproved; see the published alcove clearances below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFactory-built fireplace\u003c\/th\u003e\n\u003ctd\u003eDo not install the Lincoln 8060 into a factory-built fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e78.5% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e1.14 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60, using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification report\u003c\/th\u003e\n\u003ctd\u003ePFS Report F22-859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 38.7 g\/hr, Category 2 (medium low) 18.2 g\/hr, Category 3 (medium high) 17.3 g\/hr, Category 4 69.0 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to CAN\/ULC Std. S627:2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Lincoln 8060 owner's and installation manual (revision 11\/10\/25). Reduced side clearances require the HearthStone side heat shield, kit 90-68605, installed on each shielded side; reduced rear clearances require the rear heat shield, kit 90-68601. Heat shields can be installed individually to reduce the required distance to the wall being shielded. Close-clearance connector pipe must be tested to UL standards and listed; double-wall figures published by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands. The manual publishes clearances both for the stove body and for the chimney connector, and the tables below state which one each row measures: stove-body rows are measured from the cast body of the stove to the combustible wall, and chimney-connector rows are measured from the connector pipe to the combustible wall. Both must be satisfied in an installation. As a general rule, keep furniture, drapes, wood, paper, and other combustibles at least 36\" (92 cm) away from the stove.\u003c\/p\u003e\n\u003cp\u003eThe clearances below apply to parallel and corner installations; the manual publishes the same values for single-wall and double-wall connector pipe in these configurations.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eNo Heat Shields\u003c\/th\u003e\n\u003cth\u003eWith Side Heat Shields 90-68605\u003c\/th\u003e\n\u003cth\u003eWith Rear Heat Shield 90-68601\u003c\/th\u003e\n\u003cth\u003eWith Side and Rear Heat Shields\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e22\" (56 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e22\" (56 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e27¼\" (70 cm)\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e27¼\" (70 cm)\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to rear wall\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e3½\" (9 cm)\u003c\/td\u003e\n\u003ctd\u003e3½\" (9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to rear wall\u003c\/td\u003e\n\u003ctd\u003e13½\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e13½\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to corner wall\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e13¾\" (35 cm)\u003c\/td\u003e\n\u003ctd\u003e7¼\" (19 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to corner wall\u003c\/td\u003e\n\u003ctd\u003e18½\" (47 cm)\u003c\/td\u003e\n\u003ctd\u003e18½\" (47 cm)\u003c\/td\u003e\n\u003ctd\u003e18½\" (47 cm)\u003c\/td\u003e\n\u003ctd\u003e12\" (31 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eThrough-the-rear-wall flue exit (elbow atop the stove to a rear wall exit)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe values below apply to through-the-rear-wall installations with a single-wall connector, and include both the stove-body and the chimney-connector clearances for each shield configuration. For double-wall connectors, use the chimney-connector clearance table that follows and refer to the connector pipe's certification where the manual directs, rather than the single-wall values.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eNo Heat Shields\u003c\/th\u003e\n\u003cth\u003eWith Side Heat Shields 90-68605\u003c\/th\u003e\n\u003cth\u003eWith Rear Heat Shield 90-68601\u003c\/th\u003e\n\u003cth\u003eWith Side and Rear Heat Shields\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e22\" (56 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003ctd\u003e22\" (56 cm)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e27¼\" (70 cm)\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003ctd\u003e27¼\" (70 cm)\u003c\/td\u003e\n\u003ctd\u003e17\" (44 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to rear wall\u003c\/td\u003e\n\u003ctd\u003eUnited States 11\"; Canada 43 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 11\"; Canada 43 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 5½\"; Canada 43 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 5½\"; Canada 43 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney connector to rear wall\u003c\/td\u003e\n\u003ctd\u003eUnited States 15½\"; Canada 54 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 15½\"; Canada 54 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 11\"; Canada 54 cm\u003c\/td\u003e\n\u003ctd\u003eUnited States 11\"; Canada 54 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eChimney-connector clearances for the through-the-wall exit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manual separately publishes the clearance from the rear combustible wall to the vertical chimney connector rising from the flue collar, and the clearance from the rear wall for the through-the-wall exit arrangement with no vertical pipe. Where the table shows check pipe certification, use the clearance established by the double-wall connector manufacturer's listing instead of a single-wall value.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eSingle-Wall Pipe, No Rear Heat Shield\u003c\/th\u003e\n\u003cth\u003eSingle-Wall Pipe, With Rear Heat Shield 90-68601\u003c\/th\u003e\n\u003cth\u003eDouble-Wall Pipe\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear wall to the vertical chimney connector, United States\u003c\/td\u003e\n\u003ctd\u003e15½\" (40 cm)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm) with the rear heat shield; otherwise check pipe certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear wall to the vertical chimney connector, Canada\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003ctd\u003eCheck pipe certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear wall to the through-the-wall exit with no vertical pipe, United States\u003c\/td\u003e\n\u003ctd\u003e12½\" (32 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm)\u003c\/td\u003e\n\u003ctd\u003e8\" (20 cm) with the rear heat shield; otherwise check pipe certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear wall to the through-the-wall exit with no vertical pipe, Canada\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003ctd\u003eCheck pipe certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSingle-wall connector pipe requires a minimum of 18\" of clearance to the ceiling. For double-wall connector pipe, follow the connector manufacturer's ceiling-clearance specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum unshielded alcove width\u003c\/td\u003e\n\u003ctd\u003e58\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, single-wall connector\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor\u003c\/td\u003e\n\u003ctd\u003e58½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, double-wall connector\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor\u003c\/td\u003e\n\u003ctd\u003e58½\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, no heat shields\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, no heat shields\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e27¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, no heat shields\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall, United States\u003c\/td\u003e\n\u003ctd\u003e11\" (Canada: see the owner's manual clearance figure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, no heat shields\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall, United States\u003c\/td\u003e\n\u003ctd\u003e15½\" (Canada: see the owner's manual clearance figure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, with side and rear heat shields\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall\u003c\/td\u003e\n\u003ctd\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, with side and rear heat shields\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, with side and rear heat shields\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall, United States\u003c\/td\u003e\n\u003ctd\u003e5½\" (Canada: see the owner's manual clearance figure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, with side and rear heat shields\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall, United States\u003c\/td\u003e\n\u003ctd\u003e11\" (Canada: see the owner's manual clearance figure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTrim and mantel clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace installation — protruding trim up to 6\" (16 cm)\u003c\/td\u003e\n\u003ctd\u003eDistance from the stove\u003c\/td\u003e\n\u003ctd\u003e13\" (33 cm) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel with 12\" protrusion, no shield\u003c\/td\u003e\n\u003ctd\u003eHeight from the floor\u003c\/td\u003e\n\u003ctd\u003e58½\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material, such as a continuous layer of tile, brick, slate, or glass. The Lincoln 8060 does not require an insulated hearth pad and there is no R-value requirement; hearth pad coverage is for ember protection. The minimum floor protection for United States installations is 27½\" x 37½\", and the minimum floor protection for installations in Canada is 30\" (762 mm) x 47½\" (1206 mm), with the stove positioned on the pad as shown in the hearth diagram in the owner's manual. Rooms with luxury vinyl plank or luxury vinyl tile flooring require extra consideration, because some of these floorings begin to warp at 110°F; consult the flooring manufacturer, as additional shielding may be necessary.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLincoln Model 8060 woodstove with catalytic combustor installed\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eHardware kit with four feet, leveling and mounting hardware, front door handle, air control handle, and catalyst temperature indicator\u003c\/li\u003e\n\u003cli\u003eFloor refractory stones, shipped loose in the firebox for final assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Heat Shield\u003c\/td\u003e\n\u003ctd\u003e90-68601\u003c\/td\u003e\n\u003ctd\u003e$59\u003c\/td\u003e\n\u003ctd\u003eFor the Lincoln 8060. Clips onto the back of the stove; required for the reduced rear clearances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Heat Shield (Left or Right)\u003c\/td\u003e\n\u003ctd\u003e90-68605\u003c\/td\u003e\n\u003ctd\u003e$89\u003c\/td\u003e\n\u003ctd\u003eFor the Lincoln 8060. A single shield that clips onto the left or right side; one shield is required for each side being shielded for the reduced side clearances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter Kit, 3\"\u003c\/td\u003e\n\u003ctd\u003e96-53400\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eListed for the Lincoln. Required for mobile home installations and recommended for well-sealed newer homes; minimum 3\" duct supplied by others.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Increaser, 3\" to 4\"\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eAdapts the outside air starter kit to a 4\" duct for longer outside air runs; listed by HearthStone as a Lincoln accessory.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components and refractory, vermiculite panels, and baffles carry a 2-year period. Enamel finish against peeling or fading, glass, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustor is covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Refer to the complete warranty in the current Lincoln 8060 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53612858409236,"sku":"8060","price":2549.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/Lincoln-8060matteblack240116.webp?v=1786152324","url":"https:\/\/cozyglowstoves.com\/products\/hearthstone-stoves-lincoln-freestanding-wood-stove","provider":"Cozy Glow Stoves","version":"1.0","type":"link"}