{"product_id":"hearthstone-stoves-manchester-freestanding-wood-stove","title":"Hearthstone Stoves Manchester Freestanding Wood Stove","description":"\u003ch2\u003eFull Cast Iron Convective Heat with TruHybrid™ Catalytic Combustion and Left-Side Loading\u003c\/h2\u003e\n\u003cp\u003eFull cast iron construction with a soapstone-lined firebox, TruHybrid™ catalytic combustion, a left-side loading door with integral ash pan, and published burn times of up to 30+ hours.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion\u003c\/li\u003e\n\u003cli\u003eEPA certified at 0.65 g\/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood\u003c\/li\u003e\n\u003cli\u003e78% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology\u003c\/li\u003e\n\u003cli\u003ePublished burn time of up to 30+ hours and HeatLife™ of up to 30 hours, depending on wood, draft, and operating conditions\u003c\/li\u003e\n\u003cli\u003eBuilt-in convective air channel up the back and across the top of the stove that helps circulate warm air through the home\u003c\/li\u003e\n\u003cli\u003eLeft-side loading door accepts logs up to 24\" in length; integral ash pan with shaker grate keeps the hearth tidy\u003c\/li\u003e\n\u003cli\u003eSoapstone-lined 2.45 cubic foot firebox stores heat and releases it gradually\u003c\/li\u003e\n\u003cli\u003eHeats up to a maximum of 2,400 square feet, depending on insulation, floor plan, stove placement, and fuel quality\u003c\/li\u003e\n\u003cli\u003eCast iron rear heat shield included from the factory\u003c\/li\u003e\n\u003cli\u003eTwo current finishes: Black Matte and Brown Enamel\u003c\/li\u003e\n\u003cli\u003e6\" flue collar with top or rear exit, and approval for U.S. mobile home installation when installed to the manufacturer's requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eTruHybrid™ Combustion Technology\u003c\/h4\u003e\n\u003cp\u003eThe TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through the catalysts for tertiary combustion. A bypass handle directs combustion products around the catalysts during startup and reloading, and through the catalysts once the catalyst thermometer shows the stove is in its active range. The Manchester uses Applied Ceramics ACI-6M2 catalytic combustors, two required per the current illustrated parts list, which require periodic inspection and eventual replacement. The catalysts become active around 500°F, and the Manchester 8362 typically operates in the 800°F to 1300°F range.\u003c\/p\u003e\n\u003ch4\u003eNatural Convective Heat\u003c\/h4\u003e\n\u003cp\u003eThe Manchester is built with an air channel up the back and across the top of the stove, which helps circulate warm air through the home without a fan. An optional blower, kit 93-57600, is available for installations that call for forced air movement.\u003c\/p\u003e\n\u003ch4\u003eCast Iron and Soapstone Construction\u003c\/h4\u003e\n\u003cp\u003eThe Manchester combines full cast iron construction with a soapstone-lined firebox. The soapstone absorbs the heat of the fire and releases it gradually, supporting the stove's long published HeatLife™. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and surface fractures may appear with use without affecting stove function.\u003c\/p\u003e\n\u003ch4\u003eSide Loading and Everyday Convenience\u003c\/h4\u003e\n\u003cp\u003eA left-side loading door accepts logs up to 24\" in length, and the built-in ash pan with a shaker grate allows ash to be sifted from the firebox and carried away without shoveling through the front door. A single primary air lever below the ash lip regulates the burn rate, the bypass handle controls catalyst engagement, and a catalyst thermometer shows when the stove is in the active temperature range. HearthStone requires 18\" between the loading-door side of the stove and the side wall unless the optional side door locking kit is installed, and recommends allowing space for loading through the side door.\u003c\/p\u003e\n\u003ch4\u003eFire Viewing\u003c\/h4\u003e\n\u003cp\u003eA large glass window lets the fire be seen from a variety of locations in the room. An air-wash system helps keep the ceramic glass clear when logs are kept away from the glass and the stove is run at adequate temperatures.\u003c\/p\u003e\n\u003ch4\u003eHeating Performance\u003c\/h4\u003e\n\u003cp\u003eHearthStone publishes a heating area of up to a maximum of 2,400 square feet and a maximum heat output of 75,000 BTU per hour of cordwood. Under specific EPA test conditions, the Manchester 8362 delivered heat at rates ranging from 14,000 to 33,000 BTU (output). HearthStone states in the current owner's manual that the Manchester should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe Manchester 8362 is currently orderable in two finishes. Both current configurations load through a left-side door. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003eLoading Configuration\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eIncluded Equipment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlack Matte\u003c\/td\u003e\n\u003ctd\u003eLeft load\u003c\/td\u003e\n\u003ctd\u003e8362-0010L\u003c\/td\u003e\n\u003ctd\u003e$5,449\u003c\/td\u003e\n\u003ctd\u003eCast iron rear heat shield included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003eLeft load\u003c\/td\u003e\n\u003ctd\u003e8362-0020L\u003c\/td\u003e\n\u003ctd\u003e$6,149\u003c\/td\u003e\n\u003ctd\u003eCast iron rear heat shield included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePricing notice:\u003c\/strong\u003e Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8362\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCombustion system\u003c\/th\u003e\n\u003ctd\u003eTruHybrid™ — primary, secondary, and catalytic tertiary combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalytic combustor\u003c\/th\u003e\n\u003ctd\u003eApplied Ceramics ACI-6M2, two required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating area\u003c\/th\u003e\n\u003ctd\u003eUp to a maximum of 2,400 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum heat output\u003c\/th\u003e\n\u003ctd\u003e75,000 BTU per hour of cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested heat output range\u003c\/th\u003e\n\u003ctd\u003e14,000 to 33,000 BTU (output) under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurn time\u003c\/th\u003e\n\u003ctd\u003eUp to 30+ hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeatLife™\u003c\/th\u003e\n\u003ctd\u003eUp to 30 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical operating range\u003c\/th\u003e\n\u003ctd\u003e800°F to 1300°F catalyst temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFirebox and Fuel\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel type\u003c\/th\u003e\n\u003ctd\u003eNatural cordwood only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFirebox capacity\u003c\/th\u003e\n\u003ctd\u003e2.45 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum log length\u003c\/th\u003e\n\u003ctd\u003eUp to 24\" (61 cm) through the side door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoading\u003c\/th\u003e\n\u003ctd\u003eFront door and left-side loading door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAsh pan\u003c\/th\u003e\n\u003ctd\u003eBuilt in, with ash door and shaker grate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions and Weight\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e32⅛\" (81.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e30¼\" (76.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e20\" (50.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e520 lbs (236 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCrate dimensions\u003c\/th\u003e\n\u003ctd\u003eH 49.5\" x W 32.4\" x L 24.5\" (126 x 82.3 x 62.2 cm); add 4\" (10.2 cm) for pallet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFlue and Installation\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue exit location\u003c\/th\u003e\n\u003ctd\u003eTop or rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue collar and connector size\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetal chimney requirement\u003c\/th\u003e\n\u003ctd\u003e6\" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMasonry chimney requirement\u003c\/th\u003e\n\u003ctd\u003eCode-approved lined chimney, 6\" (152 mm) round flue or 8\" x 8\" (203 x 203 mm) square flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, top exit\u003c\/th\u003e\n\u003ctd\u003e16 feet (4.9 m) off the floor, or 13 feet 5⅛\" (4.1 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended minimum chimney height, rear exit\u003c\/th\u003e\n\u003ctd\u003e19 feet (5.8 m) off the floor, or 16 feet 5⅛\" (5.0 m) from the top of the stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended maximum chimney height\u003c\/th\u003e\n\u003ctd\u003e30 feet (9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired draft\u003c\/th\u003e\n\u003ctd\u003e0.06\" to 0.1\" water column; drafts above 0.1\" WC require a stovepipe damper, checked at installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutside air connection\u003c\/th\u003e\n\u003ctd\u003eOptional kit 93-53500, minimum 3\" (76 mm) diameter duct supplied by others; adaptor 90-53308 available for 4\" duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile home approval\u003c\/th\u003e\n\u003ctd\u003eApproved in the U.S. when installed per 24 CFR Part 3280; outside air kit, floor anchoring, a spark arrester, and a listed mobile home chimney and connector kit are required; not for installation in a sleeping room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFireplace installation\u003c\/th\u003e\n\u003ctd\u003eNot to be installed in any factory-built fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEfficiency, Emissions, and Certification\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHHV efficiency\u003c\/th\u003e\n\u003ctd\u003e78% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParticulate emissions\u003c\/th\u003e\n\u003ctd\u003e0.65 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEPA certification\u003c\/th\u003e\n\u003ctd\u003eCertified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60 where applicable, using crib wood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification file\u003c\/th\u003e\n\u003ctd\u003ePFS File F19-023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO emissions by burn category\u003c\/th\u003e\n\u003ctd\u003eCategory 1 (low) 40.46 g\/hr, Category 2 (medium low) 37.04 g\/hr, Category 3 (medium high) 63.46 g\/hr, Category 4 79.04 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTested standards\u003c\/th\u003e\n\u003ctd\u003eConforms to UL Std. 1482-2022; certified to ULC Std. S627-2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003eThe values below are from the current Manchester 8362 owner's and installation manual (revision 1\/9\/23) and are measured from the body of the stove unless otherwise indicated. The cast iron rear heat shield is included from the factory, and the published clearances apply to the stove as shipped. Reduced clearances require the optional close clearance heat shield, kit 93-68600, which is sold separately. Double-wall connector figures shown by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands; check the specifications from the manufacturer of your connector.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (dimension A)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (dimension B)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (dimension C)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (dimension D)\u003c\/td\u003e\n\u003ctd\u003e33⅝\" (86 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to corner wall (dimension E)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (dimension A)\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (dimension B)\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (dimension C)\u003c\/td\u003e\n\u003ctd\u003e15\" (39 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (dimension D)\u003c\/td\u003e\n\u003ctd\u003e33⅝\" (86 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to corner wall (dimension E)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (dimension A)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (dimension B)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (dimension C)\u003c\/td\u003e\n\u003ctd\u003e21\" (54 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (dimension D)\u003c\/td\u003e\n\u003ctd\u003e31⅝\" (81 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector, no close clearance heat shield\u003c\/td\u003e\n\u003ctd\u003eStove body to corner wall (dimension E)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to side wall (dimension A)\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to rear wall (dimension B)\u003c\/td\u003e\n\u003ctd\u003e6\" (16 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eChimney connector to rear wall (dimension C)\u003c\/td\u003e\n\u003ctd\u003e11\" (28 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eChimney connector to side wall (dimension D)\u003c\/td\u003e\n\u003ctd\u003e31⅝\" (81 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall connector with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eStove body to corner wall (dimension E)\u003c\/td\u003e\n\u003ctd\u003e9\" (23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSide loading door:\u003c\/strong\u003e The side of the stove with the loading door must be 18\" from the side wall unless the side door locking kit, 93-70607, is installed. HearthStone advises considering space for loading the stove through the side door.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChimney connector clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Type and Configuration\u003c\/th\u003e\n\u003cth\u003eVertical Pipe Length Before Elbow\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003e18\" or more\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe without heat shield\u003c\/td\u003e\n\u003ctd\u003e18\" or more\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eLess than 18\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe without heat shield\u003c\/td\u003e\n\u003ctd\u003eLess than 18\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-wall pipe, direct rear exit\u003c\/td\u003e\n\u003ctd\u003eDirect rear exit\u003c\/td\u003e\n\u003ctd\u003e14\" without heat shield; heat shield configuration listed as N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003e18\" or more\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe without heat shield\u003c\/td\u003e\n\u003ctd\u003e18\" or more\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe with close clearance heat shield 93-68600\u003c\/td\u003e\n\u003ctd\u003eLess than 18\"\u003c\/td\u003e\n\u003ctd\u003e10\" (26 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe without heat shield\u003c\/td\u003e\n\u003ctd\u003eLess than 18\"\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble-wall pipe, direct rear exit\u003c\/td\u003e\n\u003ctd\u003eDirect rear exit\u003c\/td\u003e\n\u003ctd\u003e6\" without heat shield; heat shield configuration listed as N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConnector clearance to ceiling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-wall connector to an unprotected ceiling:\u003c\/strong\u003e 18\" minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-wall connector to a protected ceiling:\u003c\/strong\u003e 9\" minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble-wall connector to the ceiling:\u003c\/strong\u003e follow the connector manufacturer's specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe close clearance heat shield referenced in the connector tables is kit 93-68600.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlcove installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Configuration\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove width\u003c\/td\u003e\n\u003ctd\u003e62¼\" (159 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMaximum alcove depth\u003c\/td\u003e\n\u003ctd\u003e52\" (132 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, single-wall connector\u003c\/td\u003e\n\u003ctd\u003e68\" (173 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, unprotected surfaces\u003c\/td\u003e\n\u003ctd\u003eMinimum alcove ceiling height from floor, double-wall connector\u003c\/td\u003e\n\u003ctd\u003e61½\" (163 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove, protected surfaces\u003c\/td\u003e\n\u003ctd\u003eAll alcove dimensions\u003c\/td\u003e\n\u003ctd\u003eSee NFPA 211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTrim and mantel clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRequired Clearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide trim clearance\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop trim clearance above the stove\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel clearance above the stove\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrim thickness shown in the manual\u003c\/td\u003e\n\u003ctd\u003e1¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual states that the same clearances apply with the stove installed in a fireplace.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHearth and floor protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombustible flooring must be protected with a covering of noncombustible material. The Manchester 8362 does not require an insulated hearth pad and there is no R-value requirement; the requirement is ember protection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFloor Protection Measurement\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eApplies To\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum overall floor protection\u003c\/td\u003e\n\u003ctd\u003e48\" x 36¾\"\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum overall floor protection\u003c\/td\u003e\n\u003ctd\u003e56\" x 44\"\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear extension from the stove body\u003c\/td\u003e\n\u003ctd\u003e2\" (6 cm)\u003c\/td\u003e\n\u003ctd\u003eUnited States and Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension from the loading-door opening\u003c\/td\u003e\n\u003ctd\u003e16\" (41 cm)\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension from the loading-door opening\u003c\/td\u003e\n\u003ctd\u003e18\" (46 cm)\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEdge of the fuel-door opening to the edge of the hearth\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStove body to the side edge of the hearth\u003c\/td\u003e\n\u003ctd\u003e8\" (21 cm)\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used. Clearances to combustible surfaces may be reduced using an NFPA 211 approved wall protection system with the additional approval of the regulatory authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation notice:\u003c\/strong\u003e Clearances and hearth requirements vary by connector type, shielding, and installation configuration. Refer to the current Manchester 8362 installation manual and applicable local requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManchester Model 8362 woodstove with catalytic combustors installed\u003c\/li\u003e\n\u003cli\u003eCast iron rear heat shield, included per the current dealer listing\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operating instructions\u003c\/li\u003e\n\u003cli\u003eBag of handles and hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eCompatibility or Requirement Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air Starter\u003c\/td\u003e\n\u003ctd\u003e93-53500\u003c\/td\u003e\n\u003ctd\u003e$129\u003c\/td\u003e\n\u003ctd\u003eFor Manchester. Required for mobile home installations; connects to a minimum 3\" duct supplied by others.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e93-57600\u003c\/td\u003e\n\u003ctd\u003e$699\u003c\/td\u003e\n\u003ctd\u003eFor Manchester. Optional convection blower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtra Close Clearance (Exit) Heat Shield\u003c\/td\u003e\n\u003ctd\u003e93-68600\u003c\/td\u003e\n\u003ctd\u003e$109\u003c\/td\u003e\n\u003ctd\u003eFor Manchester. Required for the reduced clearances shown in the clearance tables. Separate from the included cast iron rear heat shield.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Door Lock Kit\u003c\/td\u003e\n\u003ctd\u003e93-70607\u003c\/td\u003e\n\u003ctd\u003e$99\u003c\/td\u003e\n\u003ctd\u003eFor Manchester. Permits the loading-door side of the stove to be closer than 18\" to the side wall.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\" to 4\" Outside Air Increaser\u003c\/td\u003e\n\u003ctd\u003e90-53308\u003c\/td\u003e\n\u003ctd\u003e$49\u003c\/td\u003e\n\u003ctd\u003eFor use when adapting the Manchester's 3\" outside-air connection to 4\" duct.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll accessories listed above are optional and sold separately unless expressly stated otherwise.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.\u003c\/p\u003e\n\u003cp\u003eWarranty periods differ by component. HearthStone defines the term \"Limited Lifetime\" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period, as do refractory and vermiculite panels and baffles. Enamel finish against peeling or fading, glass, the ash grate, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.\u003c\/p\u003e\n\u003cp\u003eHearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Manchester 8362 owner's manual for the full terms, conditions, and limitations.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53616113975572,"sku":"8362","price":5449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/manchester8362_brown_CMYK.webp?v=1786235846","url":"https:\/\/cozyglowstoves.com\/products\/hearthstone-stoves-manchester-freestanding-wood-stove","provider":"Cozy Glow Stoves","version":"1.0","type":"link"}