{"product_id":"hearthstone-stoves-wfp-75-zero-clearance-wood-fireplace","title":"Hearthstone Stoves WFP-75 Zero Clearance Wood Fireplace","description":"\u003ch2\u003eBuilt-In Wood Heat and Classic Cast-Iron Character in a Zero-Clearance Fireplace\u003c\/h2\u003e\n\u003cp\u003eThe WFP-75 (Model 8411) is an EPA-certified zero-clearance wood fireplace pairing a 2.5 cu. ft. firebox, a single cast-iron-framed glass door, and an included convection blower.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 cu. ft. firebox\u003c\/strong\u003e — accepts logs up to 20\" loaded east-west, with a 16\" north-south log length recommended by the current owner's manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum heat output up to 80,000 BTU\/hr\u003c\/strong\u003e — with dry cordwood, per the current owner's manual, and a recommended heating area of 750 to 2,200 sq. ft. depending on home layout, insulation, and operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA certified using cordwood\u003c\/strong\u003e — certified at 1.14 g\/hr average particulate emissions, with a tested overall heat output of 14,200–48,200 BTU\/hr under specific test conditions and a 68% (HHV) average overall efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-catalytic double combustion\u003c\/strong\u003e — a primary and secondary combustion system with secondary-air tubes beneath a C-Cast baffle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum burn time up to 9 hours\u003c\/strong\u003e — per the current owner's manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded convection blower\u003c\/strong\u003e — rated up to 176 CFM to move warmed air into the living space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle ceramic-glass door with cast-iron frame\u003c\/strong\u003e — a wide view of the fire behind a chiseled-texture cast-iron facade in Matte Black or Brown Enamel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-clearance construction\u003c\/strong\u003e — engineered for framed new-construction and remodeling installations with a dedicated 6\" chimney system; the specified clearances, framing, facing, and hearth protection in the current manual still apply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003ch4\u003eZero-Clearance Built-In Design\u003c\/h4\u003e\n\u003cp\u003eThe WFP-75 is a built-in wood-burning fireplace designed to be framed into new construction or a remodel, without the mass and footprint of a site-built masonry fireplace. The fireplace enclosure permits 0\" clearance at the back, sides, and floor under the fireplace, while every other published clearance, framing, facing, and hearth requirement in the current Model 8411 manual applies. The arched face measures approximately 35-1\/2\" wide by 37\" tall per the current HearthStone catalog, with a door opening of approximately 24-1\/2\" wide by 12-3\/4\" tall per the current manual's dimensional drawing.\u003c\/p\u003e\n\u003ch4\u003e2.5 Cu. Ft. Firebox\u003c\/h4\u003e\n\u003cp\u003eThe 2.5 cu. ft. firebox burns dry, seasoned cordwood and accepts logs up to 20\" long loaded east-west. The current owner's manual recommends 16\" logs loaded north-south for everyday burning. Published maximum burn time is up to 9 hours, depending on wood, draft, and operating conditions.\u003c\/p\u003e\n\u003ch4\u003eNon-Catalytic Double Combustion\u003c\/h4\u003e\n\u003cp\u003eA non-catalytic double-combustion system burns the wood and then the gases it releases. Secondary-air tubes beneath the C-Cast baffle supply air to complete combustion before the exhaust enters the chimney. The system is EPA certified using cordwood at 1.14 g\/hr average particulate emissions, with a 68% (HHV) and 73% (LHV) average overall efficiency and an optimum efficiency of 74% (LHV) at a specific burn rate, per the current owner's manual.\u003c\/p\u003e\n\u003ch4\u003eIncluded Convection Blower\u003c\/h4\u003e\n\u003cp\u003eA convection blower rated up to 176 CFM is included with the fireplace, drawing room air around the firebox and returning warmed air to the living space.\u003c\/p\u003e\n\u003ch4\u003eChiseled Cast-Iron Facade\u003c\/h4\u003e\n\u003cp\u003eThe facade is European cast iron with HearthStone's chiseled stone texture, finished in Matte Black or Brown Enamel, and it ships installed on the fireplace. The single ceramic-glass door is framed in cast iron and gives the WFP-75 the open sightline of a traditional hearth.\u003c\/p\u003e\n\u003ch4\u003eRefractory Ceramic Interior\u003c\/h4\u003e\n\u003cp\u003eThe firebox is lined with refractory ceramic panels that reflect heat back into the fire for cleaner combustion and give the firebox a finished masonry appearance.\u003c\/p\u003e\n\u003ch4\u003eFlexible Heat Distribution\u003c\/h4\u003e\n\u003cp\u003eBeyond the included blower, the optional Forced Air Convection Kit (94-57110) can move heat to another room up to 50 ft away, and the optional Hot Air Distribution \/ Gravity Convection Kit (94-99100) adds two gravity hot-air outlets above the fireplace. Fresh-air connector components — a 4\" adapter, an air-inlet block-off plate, and four screws — are included with the fireplace for installations that connect outside combustion air.\u003c\/p\u003e\n\u003ch4\u003eDedicated 6-Inch Chimney System\u003c\/h4\u003e\n\u003cp\u003eThe WFP-75 uses a dedicated 6\" chimney system listed to UL 103 HT (2100°F) or CAN\/ULC S629, beginning with a listed 6\" anchor plate secured to the fireplace. The minimum straight system height is 15 ft from the base of the fireplace to the chimney cap, and the fireplace must never share a flue with any other appliance.\u003c\/p\u003e\n\u003ch3\u003eAvailable Finishes and Configurations\u003c\/h3\u003e\n\u003cp\u003eThe WFP-75 is a single base model available in two finishes. Pricing varies by finish.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatte Black\u003c\/td\u003e\n\u003ctd\u003e8411-0010\u003c\/td\u003e\n\u003ctd\u003e$5,599\u003c\/td\u003e\n\u003ctd\u003eShips with the included convection blower and fresh-air connector components.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrown Enamel\u003c\/td\u003e\n\u003ctd\u003e8411-0020\u003c\/td\u003e\n\u003ctd\u003e$6,499\u003c\/td\u003e\n\u003ctd\u003eShips with the included convection blower and fresh-air connector components.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWFP-75, Model 8411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eZero-clearance wood-burning fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eDry, seasoned cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion system\u003c\/td\u003e\n\u003ctd\u003eNon-catalytic primary and secondary (double) combustion with secondary-air tubes and C-Cast baffle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output\u003c\/td\u003e\n\u003ctd\u003eUp to 80,000 BTU\/hr with dry cordwood, per the current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested overall heat output\u003c\/td\u003e\n\u003ctd\u003e14,200–48,200 BTU\/hr under specific test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage overall efficiency\u003c\/td\u003e\n\u003ctd\u003e68% (HHV); 73% (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum efficiency\u003c\/td\u003e\n\u003ctd\u003e74% (LHV) at a specific burn rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA particulate emissions\u003c\/td\u003e\n\u003ctd\u003e1.14 g\/hr average, certified using cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended heating area\u003c\/td\u003e\n\u003ctd\u003e750 to 2,200 sq. ft., depending on home and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e20\", east-west\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended log length\u003c\/td\u003e\n\u003ctd\u003e16\", north-south, per the owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum burn time\u003c\/td\u003e\n\u003ctd\u003eUp to 9 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney\u003c\/td\u003e\n\u003ctd\u003e6\" diameter, listed to UL 103 HT (2100°F) or CAN\/ULC S629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaffle\u003c\/td\u003e\n\u003ctd\u003eC-Cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor\u003c\/td\u003e\n\u003ctd\u003eSingle ceramic-glass door with cast-iron frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFace dimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 35-1\/2\" W × 37\" H, arched, per the current catalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eIncluded, rated up to 176 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog listed weight\u003c\/td\u003e\n\u003ctd\u003e400 lb, per the current HearthStone catalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual listed weight\u003c\/td\u003e\n\u003ctd\u003e575 lb, including refractory panels, faceplate, and packaging, per the current owner's manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove installation\u003c\/td\u003e\n\u003ctd\u003eNot approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile \/ manufactured home installation\u003c\/td\u003e\n\u003ctd\u003eNot approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety listing\u003c\/td\u003e\n\u003ctd\u003eUL 127 (USA); ULC-S610 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish options\u003c\/td\u003e\n\u003ctd\u003eMatte Black or Brown Enamel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation, Clearances and Hearth Requirements\u003c\/h3\u003e\n\u003cp\u003e\"Zero clearance\" describes this class of built-in fireplace, not an absence of requirements. The current Model 8411 manual permits 0\" enclosure clearance at the back, sides, and floor under the fireplace, and at the same time requires the combustible clearances, noncombustible facing, hearth protection, and chimney clearance below. The current owner's manual and its drawings govern every installation; review them with your installer and local building official.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClearance\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible side trim, from the door opening\u003c\/td\u003e\n\u003ctd\u003e8\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjacent combustible side wall, from the door opening\u003c\/td\u003e\n\u003ctd\u003e13\" minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible side-trim projection\u003c\/td\u003e\n\u003ctd\u003e3\" maximum, as shown by the manual's clearance figure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible wall in front of the fireplace\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeiling\u003c\/td\u003e\n\u003ctd\u003e80\", measured from the base of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace enclosure, back\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace enclosure, sides\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor under the fireplace\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney, to combustibles\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe current manual publishes three hearth and floor-protection configurations. All three are reproduced below.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHearth Configuration\u003c\/th\u003e\n\u003cth\u003eRequired R-value\u003c\/th\u003e\n\u003cth\u003eMinimum front protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 1 — installed directly on the floor\u003c\/td\u003e\n\u003ctd\u003eR 1.00\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 2 — raised 4\" or less from the floor\u003c\/td\u003e\n\u003ctd\u003eR 1.00\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 3 — raised more than 4\" from the floor\u003c\/td\u003e\n\u003ctd\u003eNo R-value requirement\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn every configuration, the hearth protection must be at least 41-1\/2\" wide in total, extending at least 8\" beyond each side of the door opening, with sheet-metal joint protection where the manual specifies it. Confirm the applicable configuration and its construction details using the current Model 8411 manual, your installer, local code, and the authority having jurisdiction.\u003c\/p\u003e\n\u003cp\u003eFraming and facing requirements include the following. These reference values do not replace the manual's complete installation drawings, and allowances may need to increase for the fresh-air kit, the forced-air kit, or the finish materials used.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming and Facing Reference\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStraight-wall framing reference\u003c\/td\u003e\n\u003ctd\u003e37-3\/4\" wide × 23-7\/8\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming material, sides and rear\u003c\/td\u003e\n\u003ctd\u003e2\" × 3\" or heavier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectly above the fireplace\u003c\/td\u003e\n\u003ctd\u003eNo combustible framing; the zone must remain empty for 80\" from the base of the fireplace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFresh-air framing allowance\u003c\/td\u003e\n\u003ctd\u003e12\" minimum on the applicable side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForced-air-kit framing allowance\u003c\/td\u003e\n\u003ctd\u003e18\" minimum on the applicable side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorner framing references\u003c\/td\u003e\n\u003ctd\u003e50-1\/4\" on each angled wall, 14-3\/8\" on each return, and 79-3\/4\" across the front, as shown by the manufacturer drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFacing\u003c\/td\u003e\n\u003ctd\u003eMaterials directly in front of the fireplace must be noncombustible within the area defined by the manual's facing drawing; the faceplate must remain removable after the finish is installed; faceplate projection minimum 3\/8\", maximum 1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoncombustible shelf\u003c\/td\u003e\n\u003ctd\u003ePermitted at 48\" or more from the base of the fireplace, regardless of shelf depth; the manual identifies this shelf as noncombustible and warns that it will be hot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eA combustible mantel or shelf must follow the current manual's shelf tables. Without the optional mantel shield, a 6\"-deep combustible shelf must be at least 58\" above the base of the fireplace, an 8\" shelf at least 60\", a 10\" shelf at least 62\", and a 12\" shelf at least 64\". With the Mantel Shield (94-79700) installed, those minimums become 50\", 52\", 54\", and 56\" respectively. For other shelf depths, the manual provides its calculation method. The current manual and accessory instructions control final mantel and shelf installation.\u003c\/p\u003e\n\u003cp\u003eThe chimney is a dedicated listed 6\" system (UL 103 HT or CAN\/ULC S629) beginning with a listed 6\" anchor plate secured to the fireplace; the manual notes the anchor plate is sold separately. The minimum system height for a straight installation is 15 ft from the base of the fireplace to the chimney cap. Where offsets are used, the manual calls for a recommended minimum 18\" rise before the first offset, a 15 ft minimum system height with two elbows, and a 17 ft minimum with four elbows. The chimney must terminate at least 3 ft above its point of contact with the roof and at least 2 ft higher than any wall, roof, or building within 10 ft, must be braced if it extends more than 5 ft above the roof, must carry a rain cap, and must maintain 2\" clearance to combustibles. A chimney venting this fireplace must not vent any other appliance. Alcove and mobile\/manufactured-home installations are not approved.\u003c\/p\u003e\n\u003cp\u003eThe WFP-75 is a zero-clearance fireplace, not a fireplace insert, and it has not been tested for installation inside a masonry chimney. For applications that connect to an existing masonry chimney, the current manual requires the chimney to be inspected, maintained with at least 1\" clearance between the exterior masonry and combustible framing or loose insulation, and relined with a listed stainless-steel liner of the same diameter as the fireplace flue outlet; no other appliance may share the chimney, and U.S. angled-connection limitations follow the exact manual.\u003c\/p\u003e\n\u003cp\u003eA supply of outside combustion air is strongly recommended and is required by some jurisdictions and codes. The fresh-air connector components included with the fireplace are a 4\" adapter, an air-inlet block-off plate, and four screws; the 4\" insulated flexible duct, outside wall termination, and two adjustable clamps are not included. The intake connects at the right side or right underside of the fireplace per the manual. The manual recommends at least 10 ft of insulated pipe to avoid condensation, with a maximum duct length of 30 ft. The outside termination must not be located more than 50% of the total chimney height, more than 10 ft above the fireplace base, or more than 3 ft below it. Combustion air must come from outside the home — never from an attic, basement, or garage.\u003c\/p\u003e\n\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConvection blower, rated up to 176 CFM (included)\u003c\/li\u003e\n\u003cli\u003eFresh-air connector components: 4\" adapter, air-inlet block-off plate, and four screws (included with the fireplace)\u003c\/li\u003e\n\u003cli\u003eChiseled cast-iron facade in the selected finish (ships installed)\u003c\/li\u003e\n\u003cli\u003eSingle ceramic-glass door with cast-iron frame (ships installed)\u003c\/li\u003e\n\u003cli\u003eRefractory ceramic firebox panels (integral to the appliance)\u003c\/li\u003e\n\u003cli\u003eC-Cast baffle and secondary-air tubes (integral combustion components)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4\" insulated flexible fresh-air duct, outside wall termination, and adjustable clamps are not included and are supplied by the installer when outside air is connected. Chimney components, including the 6\" anchor plate, are sold separately.\u003c\/p\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cp\u003eAccessories are sold separately and installed per their instructions and the current Model 8411 manual.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003ePart ID\u003c\/th\u003e\n\u003cth\u003eMSRP\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForced Air Convection Kit\u003c\/td\u003e\n\u003ctd\u003e94-57110\u003c\/td\u003e\n\u003ctd\u003e$1,299\u003c\/td\u003e\n\u003ctd\u003eConnects to either side of the WFP-75 — the manual notes the left side provides better performance — and can distribute heat to another room up to 50 ft away when installed to the manufacturer's instructions. Insulated flexible HVAC pipe is not included, and ducting must meet the applicable ULC S110 \/ UL 181 requirements and temperature rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMantel Shield\u003c\/td\u003e\n\u003ctd\u003e94-79700\u003c\/td\u003e\n\u003ctd\u003e$239\u003c\/td\u003e\n\u003ctd\u003ePermits the reduced combustible-shelf heights shown in the manual's heat-shield table (50\" to 56\" depending on shelf depth). Install per the current manual and accessory instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Air Distribution \/ Gravity Convection Kit\u003c\/td\u003e\n\u003ctd\u003e94-99100\u003c\/td\u003e\n\u003ctd\u003e$429\u003c\/td\u003e\n\u003ctd\u003eAdds two gravity hot-air outlets; both outlets must be installed, at least 68\" above the base of the fireplace, with a maximum duct length of 10 ft including elbows, no more than two elbows per duct, and 12\" minimum from the outlet frame to combustible ceilings, side walls, or mantels. Rigid 8\" ducting is not included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe WFP-75 is covered by the limited warranty published in the current Model 8411 owner's manual. In summary: combustion chamber welds, castings, the convector air-mate, and ceramic glass against thermal breakage carry lifetime parts coverage with four years of labor; plating carries lifetime parts coverage for manufacturing defects, subject to the written terms; stainless-steel firebox components, surrounds and heat shields, the C-Cast baffle, and secondary-air tubes carry five years parts and three years labor; carbon-steel firebox components, glass retainers, and the handle assembly carry three years parts and two years labor; blowers, heat sensors, switches, rheostats, wiring, and controls carry two years parts and one year labor; and paint peeling, gaskets, insulation, and firebrick carry one year parts coverage. Lifetime coverage is subject to a one-time replacement limit. Coverage applies to the original consumer purchaser of a brand-new product in normal residential use, is not transferable, and requires authorized, qualified installation. See the current written warranty for complete terms.\u003c\/p\u003e\n\u003ch3\u003eAbout HearthStone\u003c\/h3\u003e\n\u003cp\u003eHearthStone Quality Home Heating Products of Morrisville, Vermont has built stoves prized for long-lasting, comfortable heat for more than four decades. The WFP-75 pairs HearthStone's chiseled European cast iron with an EPA-certified zero-clearance wood fireplace, offered through authorized dealers.\u003c\/p\u003e\n\u003cp\u003eCozy Glow Stoves is an authorized HearthStone dealer. Visit our Logan, Ohio showroom to see HearthStone products in person, or contact us with questions about the WFP-75, current pricing, and installation planning.\u003c\/p\u003e","brand":"Hearthstone Stoves","offers":[{"title":"Default Title","offer_id":53707956388116,"sku":"8411","price":5599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9381\/2756\/files\/WFP758411_matteblack_200218.webp?v=1787447149","url":"https:\/\/cozyglowstoves.com\/products\/hearthstone-stoves-wfp-75-zero-clearance-wood-fireplace","provider":"Cozy Glow Stoves","version":"1.0","type":"link"}