Drolet Heat Commander II Wood Burning Furnace | DF02003
Questions?
Call 1-888-323-2699, or start a chat with us today. We are available Mon.-Fri. 9 am - 5 pm EST.
Questions?
Call 1-888-323-2699, or start a chat with us today. We are available Mon.-Fri. 9 am - 5 pm EST.
The Drolet Heat Commander II is a central warm-air wood furnace for 1,000–2,500 ft², with a 3.6 ft³ firebox, 21" logs, up to 10 hours of burn time, and thermostat-driven combustion control.
The Heat Commander II is a central warm-air wood furnace, not a freestanding room stove, fireplace insert, or zero-clearance fireplace. It heats by supplying warm air to a hot-air plenum and duct system engineered for the building, with a separate cold-air return. Overall heat output includes radiated and delivered heat, while delivered output refers to heat provided remotely through the duct system. The 310,000 BTU figure is the maximum input capacity on dry cordwood, not delivered heat output. Installation must follow the certification label and the current installation and operating manual.
The furnace uses Dual Fire two-stage electronic combustion control: automated air controls respond to thermostat demand, the furnace modulates from higher to lower combustion based on thermostatic demand, the combustion-state indicator and reload light communicate the operating condition, and the plenum RTD probe controls the distribution blower. A fixed wall-mounted 24 V thermostat is required and must be installed according to the current manual. The furnace requires regular fueling, ash management, and maintenance; it is not maintenance-free or self-cleaning.
| Component | Details |
|---|---|
| Direct-drive blower | 1/3 hp, one speed, 875 CFM at the current manual’s published test condition |
| Fixed wall-mounted thermostat | 24 V, installed per the current manual |
| Adjustable hot-air plenum assembly | Included |
| Combustion-state indicator / reload light | Included |
| Automated combustion-control system | Dual Fire two-stage electronic control |
| Ash lip | 1 |
| Ash drawer | Included |
| Poker | Included |
| Scraper | Included |
| Hot-air plenum assembly hardware | Supplied according to the current manual |
Optional air filters (published optional size 15" x 20" x 1") and the optional return-air adapter are not included. A chimney, connector pipe, ductwork, registers, building wiring, hearth protection, barometric draft control, additional combustion-air duct, and installation labor are not included.
| Specification | Value |
|---|---|
| Fuel Type | Dry cordwood (16" recommended) |
| Heating Area | 1,000 - 2,500 ft² |
| Overall Firebox Volume | 3.6 ft³ |
| Maximum Burn Time | 10 h |
| Maximum Input Capacity (Dry Cordwood) | 310,000 BTU |
| Nominal Heat Output at 15 lb/ft³ Fuel Loading Density | 75,000 BTU |
| Minimum Overall Heat Output Rate | 21,742 BTU/h (6.37 kW) |
| Maximum Overall Heat Output Rate | 62,107 BTU/h (18.2 kW) |
| Minimum Delivered Heat Output Rate | 19,851 BTU/h (5.82 kW) |
| Maximum Delivered Heat Output Rate | 64,073 BTU/h (18.8 kW) |
| Optimum Efficiency | 79% (LHV) |
| Optimum Heat Transfer Efficiency | 81% |
| Average Particulate Emission Rate | 0.09 lb/mmBTU (0.039 g/MJ) |
| Average CO | 1.3 g/min |
| Average Electrical Power Consumption | 330 W |
| Average Overall Efficiency | 78% (HHV) |
| Average Delivered Efficiency | 77% (HHV) |
| Specification | Value |
|---|---|
| Size | Medium |
| High-Efficiency Certified Appliance | Yes, EPA 2020 approved |
| Certified According to Applicable Standards | By an accredited laboratory (CAN/USA) |
| Premium Quality Blower (CFM) | Included |
| Blower (hp | speed | CFM) | 1/3 | 1 | 875 (per the current model manual) |
| Stainless-Steel Secondary-Air System | Yes |
| Specification | Value |
|---|---|
| Flue Outlet Diameter | 6" |
| Recommended Chimney Diameter | 6" |
| Type of Chimney | CAN/ULC S629, UL 103 HT (2100 °F) |
| Evacuation Direction | Horizontal |
| Distance - Center of the Flue Outlet to Floor | 37 1/8" |
| Distance - Center of the Flue Outlet to Side of Unit | 13 7/8" |
| Specification | Value |
|---|---|
| Door Type | Single, glass with cast iron frame |
| Door Opening Size (Width) | 13 3/4" |
| Door Opening Size (Height) | 10" |
| Glass Type | Ceramic glass |
| Glass Surface - W x H | 12 3/8" x 10 1/8" |
| Baffle Type | C-Cast or equivalent |
| Firebox Size (Width) | 18 3/4" |
| Firebox Size (Height) | 16 1/8" |
| Firebox Size (Depth) | 22 3/4" (per the official appliance drawing) |
| Maximum Log Length | 21" |
| Log Positioning | Loading over width and over depth |
| Firebox Lined with Refractory Bricks | Yes |
| Steel Thickness - Top | 1/4" |
| Steel Thickness - Body | 3/16" |
| Specification | Value |
|---|---|
| Overall Dimension (Width) | 27 3/4" |
| Overall Dimension (Height) | 63 1/2" min. |
| Overall Dimension (Depth) | 51 1/2" maximum (per the official appliance drawing) |
| Filter - Dimensions (Width x Height x Depth) | 15" x 20" x 1" (option) |
| Hot Air Plenum - Minimum Height of the Furnace with Plenum | 63 1/2" min. for a 69" ceiling | 73 1/4" to 88" for a ceiling of 78 1/4" to 93" and more |
| Hot Air Plenum - Height (Minimum - Maximum) | 22 3/8" x 26 7/8" (plenum horizontal dimensions per the official drawing; see Furnace and Plenum Dimensions) |
| Canadian Standard (Safety) | CAN/CSA B366.1 |
| USA Standard (Safety) | UL 391 |
| Canadian Standard (Emissions) | CSA B415.1-10 |
| USA Standard (Emissions) | EPA |
| Warranty | Limited lifetime |
| Shipping Weight | 758 lb (344 kg) |
| Component | Published Dimension |
|---|---|
| Furnace Width | 27 3/4" |
| Maximum Overall Depth | 51 1/2" |
| Minimum Furnace Height with Plenum | 63 1/2" |
| Plenum Horizontal Dimensions | 22 3/8" x 26 7/8" |
| Adjustable Plenum Height | 22 1/2" to 47" |
| Maximum Configured Furnace Height | 88" |
The plenum footprint, the adjustable plenum height, and the total configured furnace height are separate published dimensions; verify ceiling height and layout against the current manual before installation.
The authorized standard configuration uses the Heat Commander II as the only appliance connected to its hot-air distribution system and its air-return system.
The current manual permits a parallel add-on configuration in the United States only when all manual requirements are satisfied, including: the wood furnace and the existing gas, oil, or electric furnace remain parallel; each furnace has its own air-return duct system; the existing furnace’s input is equal to or greater than the wood furnace’s applicable rating; the greater applicable appliance and duct clearances govern; the wood furnace’s static pressure is adjusted to 0.20 in. W.C. (50 Pa); and the controls are properly interlocked so both appliances do not operate at maximum rate simultaneously.
DF02003 is not approved for installation in series with another furnace; the hot-air outlet of one furnace must never feed the return-air side of the other. The furnace is not approved for mobile-home installation, not approved for alcove installation, and not approved to share a chimney flue with another appliance. Air ducts serving a garage must remain isolated as required by the manual. Installation must follow the certification label and the current manual.
| Requirement | Value |
|---|---|
| Hot-Air Plenum Outlets | 6 to 10 |
| Outlet Diameter | 6" |
| Required Plenum Static Pressure | 0.20 in. W.C. (50 Pa) |
| Maximum Main-Duct Run | 35 ft |
| Maximum Combined Main-Duct Length | 180 ft |
| Maximum Secondary-Duct Run | 10 ft |
| Maximum Combined Secondary-Duct Length | 100 ft |
| Maximum Secondary Outputs per Main Duct | 3 |
| Recommended Register-Air Velocity | 500 - 750 ft/min |
The installer is responsible for system design and performance: duct quantity, length, size, balancing, insulation, and return-air capacity depend on the building, and duct sizing and configuration must follow the complete current manual. The total cold-air return volume should be at least equal to or slightly greater than the hot-air distribution volume, and rigid ductwork is favored by the manual because it is less restrictive. The furnace is not a plug-and-play room heater, and not every duct system, chimney, electrical service, or return-air layout is compatible without evaluation. The optional return-air adapter is a room-air return accessory that may improve circulation - it is not an outside-air intake, and return air and combustion air remain separate systems. The optional air-filter system is recommended by the manual to reduce dust circulation and protect the blower; neither the adapter nor the filters are included.
A 6" listed solid-fuel chimney (CAN/ULC S629 or UL 103 HT) is strongly recommended; a 7" chimney may be permitted only when proper venting is verified and authorized by a qualified installer. The furnace must not share a chimney flue with another appliance, no manual flue damper may be installed, connector joints must be secured according to the current manual, chimney and connector systems must follow their manufacturers’ instructions and applicable requirements, and draft must be measured and calibrated according to the current manual. No chimney or connector system is included.
The electrical supply is 120 V on a recommended dedicated 15 A circuit, with a minimum wire temperature rating of 167°F (75°C). The thermostat is a fixed wall-mounted 24 V unit wired with 18 AWG two-conductor wire. The furnace arrives factory assembled electrically and normally connects through its power cord; installation and verification must be completed by a qualified person, electrical work must comply with applicable codes, and the plenum RTD probe must be positioned and connected according to the current manual.
The information on the certification label affixed to the appliance always overrides information published in any other media. The current July 17, 2026 manual and its diagrams govern; ducts require a 1" clearance to combustible materials per the current manual.
| Manual Reference | Canada | USA |
|---|---|---|
| A — From the Back of the Blower Box | 14 1/4" | 14 1/4" |
| B — See Current Manual Diagram | 18" | 18" |
| C — See Current Manual Diagram | 5" | 5" |
| D — See Current Manual Diagram | 1" | 1" |
| E — See Current Manual Diagram | 69" minimum | 69" minimum |
| F — See Current Manual Diagram | 12" | 12" |
| G — See Current Manual Diagram | 5" | 5" |
| H — See Current Manual Diagram | 24" minimum | 24" minimum |
| I — See Current Manual Diagram | 11" | 11" |
| Manual Reference | Canada | USA |
|---|---|---|
| A — From the Back of the Blower Box | 6 3/4" | 6 3/4" |
| B — See Current Manual Diagram | 11 1/2" recommended; otherwise use the connector manufacturer’s clearance | 11 1/2" recommended; otherwise use the connector manufacturer’s clearance |
| C — See Current Manual Diagram | 5" | 5" |
| D — See Current Manual Diagram | 1" | 1" |
| E — See Current Manual Diagram | 69" minimum | 69" minimum |
| F — See Current Manual Diagram | 12" | 12" |
| G — See Current Manual Diagram | 5" | 5" |
| H — See Current Manual Diagram | 24" minimum | 24" minimum |
| I — See Current Manual Diagram | 11" | 11" |
| Requirement | Canada | USA |
|---|---|---|
| Cold-Air Return Ductwork to Combustibles | 0" | 0" |
| Manual Reference | Canada | USA |
|---|---|---|
| A — See Current Manual Diagram | 18" from the door opening | 16" from the door opening |
| B — See Current Manual Diagram | N/A | 8" from the door opening |
| C — See Current Manual Diagram | 8" | N/A |
| D — See Current Manual Diagram | 8", subject to Note 1 | N/A |
| E — See Current Manual Diagram | N/A | 2", subject to Note 2 |
| F — See Current Manual Diagram | 74" | 64" |
| G — See Current Manual Diagram | 43 3/4" | 30 1/4" |
Floor protection must be steel with a minimum thickness of 0.015" or sealed ceramic tile; no protector is required over an approved noncombustible floor. Note 1: rear protection is limited to the furnace’s required rear clearance when that clearance is smaller. Note 2: the protection applies beneath the horizontal connector and extends at least 2" beyond each side. Follow the current manual diagram, material requirements, certification label, and applicable local requirements.
Drolet is a Canadian hearth and central-heating brand with roots dating back to 1875, manufactured by Stove Builder International (SBI) in Québec, Canada. Its wood furnaces are developed for North American homes and tested to the applicable CAN/USA standards.
Drolet central-heating appliances are tested by accredited laboratories, and the Heat Commander II is EPA 2020 approved with published emission, efficiency, and output data.
The manufacturer supports owners through warranty registration, replacement-parts resources, and technical-support services.