Drolet Escape 1800-I Wood-Burning Fireplace Insert with Trio 35' Venting Package (DB03128K)
A Large EPA-Certified Wood Insert Packaged with a Brushed Nickel Trim Faceplate and 35-Foot Liner Kit
The Drolet DB03128K package combines the Escape 1800-I insert, a 32" x 50" faceplate with brushed nickel trim, and a 35-foot, 6" Vortex stainless-steel liner system. The insert heats 500–2,100 ft² and includes a 144 CFM blower.
This manufacturer package combines the insert, faceplate, and specified liner components in one SKU. Additional site-specific materials, hearth protection, repairs, electrical work, or installation components may be required under the current manual and local requirements.
Key Features
- Recommended heating area of 500–2,100 ft² with up to 75,000 BTU/h maximum heat output
- EPA 2020 certified non-catalytic combustion at 2.3 g/h particulate emissions
- 2.4 ft³ firebox loading over width, accepting logs up to 20" with up to 8 hours of burn time
- 144 CFM premium quality blower included
- Packaged with a 32" x 50" faceplate with brushed nickel trim and a 35-foot, 6" Vortex flexible stainless steel liner kit
- 3/16" steel body and 5/16" steel top reinforced with a stainless steel heat shield
- Glass airwash system for a cleaner view of the flames
- Suitable for masonry fireplaces only; proudly made in Canada and the USA
Package Contents
| Component |
Details |
| Escape 1800-I wood insert |
2.4 ft³ non-catalytic wood-burning insert |
| Faceplate |
32" x 50" with brushed nickel trim |
| 6" liner |
35' Vortex flexible stainless steel liner |
| Connector |
Included in the 6" liner kit |
| Top plate |
13" x 13" |
| Chimney cap |
Without screen |
| Blower |
144 CFM premium quality blower |
| Ceramic glass |
Installed in the cast iron door |
| Ash lip |
Included |
| Air damper |
Included |
Product Features
Masonry Fireplace Installation Only
This wood-burning insert is designed only for installation inside an existing masonry fireplace with a minimum opening of 28 7/8" wide x 23 3/8" high x 15 3/4" deep, and must never be installed in a wooden or combustible structure. It is not a zero-clearance fireplace. Installation must follow the current manual, the certification label on the appliance, the liner instructions, and applicable local requirements; a site-specific installation may require components or work beyond the items included with this package, and the included 35-foot liner is not represented as suitable for every chimney height or fireplace configuration. The liner system is 6" with a minimum chimney height of 12'.
Heating Performance for 500–2,100 Square Feet
Rated to heat 500 to 2,100 ft², the Escape 1800-I provides up to 75,000 BTU/h of maximum heat output from its 2.4 ft³ firebox, subject to installation and operating conditions.
EPA 2020 Certified Clean Combustion
This large non-catalytic insert is EPA 2020 approved with an average particulate emission rate of 2.3 g/h and uses a stainless steel secondary-air system to support more complete combustion.
Included 144 CFM Blower
The Escape 1800-I includes a 144 CFM premium quality blower as standard equipment to increase warm-air circulation from the appliance.
Firebox with Width Loading
The 21" wide firebox loads logs over its width, accepts logs up to 20", and provides up to 8 hours of burn time under applicable operating conditions.
Cast Iron Door with Airwash System
The single cast iron framed door carries a 16" x 9 1/4" ceramic glass surface, kept clearer by the integrated glass airwash system.
Robust Steel Construction
The insert combines a 3/16" steel body with a 5/16" steel top reinforced with a stainless steel heat shield.
Product Specifications
Appliance Performance
| Specification |
Value |
| Fuel Type |
Dry cordwood (16" recommended) |
| Heating Area |
500 – 2,100 ft² |
| Overall Firebox Volume |
2.4 ft³ |
| EPA Loading Volume |
1.95 ft³ |
| Maximum Burn Time |
8 h |
| Maximum Heat Output – Dry Cordwood |
75,000 BTU/h (22.0 kW) |
| Minimum Overall Heat Output Rate |
14,200 BTU/h (4.16 kW) |
| Maximum Overall Heat Output Rate |
44,500 BTU/h (13.04 kW) |
| Average Overall Efficiency – Dry Cordwood (HHV) |
72% |
| Average Overall Efficiency – Dry Cordwood (LHV) |
77% |
| Optimum Efficiency |
79% |
| Optimum Heat Transfer Efficiency |
76% |
| Average Particulate Emission Rate |
2.3 g/h |
| Average CO Output |
69 g/h |
General Features
| Feature |
Specification |
| Size Category |
Large |
| Premium Quality Blower (CFM) |
144 CFM included |
| Combustion Technology |
Non-catalytic |
| Stainless Steel Secondary-Air System |
Yes |
| Door Type |
Single, glass with cast iron frame |
| Glass Type |
Ceramic glass |
| Glass Surface (W x H) |
16" x 9 1/4" |
| Steel Thickness – Body |
3/16" |
| Steel Thickness – Top |
5/16" |
| Log Positioning |
Loading over width |
| Maximum Log Length |
20" |
| Firebox Lined with Refractory Bricks |
Yes |
| Baffle Type |
High quality vermiculite |
| Warranty |
Limited lifetime |
Dimensions and Weight
| Measurement |
Size |
| Overall Width |
28 3/8" |
| Overall Height |
23 1/8" |
| Overall Depth |
26 3/8" |
| Door Opening (Width) |
17 1/2" |
| Door Opening (Height) |
9" |
| Firebox Size (Width) |
21" |
| Firebox Size (Height) |
11 7/8" |
| Firebox Size (Depth) |
16 1/2" |
| Shipping Weight |
500 lb (227 kg) |
Minimum Masonry Fireplace Opening
| Measurement |
Minimum Size |
| Minimum Fireplace Opening (Width) |
28 7/8" |
| Minimum Fireplace Opening (Height) |
23 3/8" |
| Minimum Fireplace Opening (Depth) |
15 3/4" |
Venting and Liner Requirements
| Specification |
Requirement |
| Flue Outlet Diameter |
6" |
| Distance – Center of Flue Outlet to Back of Unit |
6 7/8" |
| Distance – Center of Flue Outlet to Side of Unit |
13 1/2" |
| Recommended Chimney Diameter |
6" |
| Type of Chimney |
Liner – ULC-S635, CAN/ULC-S640, UL1777 |
| Minimum Chimney Height |
12' |
The included liner kit is intended to satisfy the liner requirement above when the specific installation permits; the current manual and certification label govern every installation.
Certifications and Installation
| Category |
Standard |
| Certified According to Applicable Standards |
By an accredited laboratory (CAN/USA) |
| High-Efficiency Certified Appliance |
Yes, EPA 2020 approved |
| Canadian Standard (Emissions) |
CSA B415.1-10 |
| USA Standard (Emissions) |
EPA / ASTM WK47329 |
| Canadian Standard (Safety) |
ULC S628 |
| USA Standard (Safety) |
UL 1482, UL 737 |
Minimum Clearances to Combustibles*
| Location |
Canada |
USA |
| Base of the Unit to Ceiling** |
84" |
84" |
| Combustible Side Mantle to Unit |
9" |
9" |
| Combustible Top Mantle to Unit |
27" |
27" |
| Combustible Side Wall to Unit |
16" |
16" |
| Top of the Unit to a 12" Combustible Mantle Shelf |
27" |
27" |
| Floor Protection in Front of the Unit (from Door Opening) |
18" |
16" |
*The certification label on the appliance and the current installation manual supersede published dimensions and clearances. Always follow the manufacturer’s installation instructions and applicable local requirements.
**Some appliances have been tested with a low ceiling; refer to the installation manual before setting up the unit.
Additional Floor Protection Requirements
The in-front floor-protection dimension above is published on the exact package page and corresponds to manual reference B. The current Escape 1800-I manual adds the side extensions below and further elevation-dependent requirements.
| Manual Reference |
Canada |
USA |
| Side Extension M — See Manual Diagram |
8" |
N/A |
| Side Extension N — See Manual Diagram |
N/A |
8" |
When the protection is level with or no more than 5" below the hearth extension, an R-value of at least 1.00 and a 23" front extension may be required. Follow the complete manual diagrams and calculations rather than relying on this summary alone.
Manufacturer Notes
- Wood-burning inserts must only be installed inside an existing masonry fireplace and never in a wooden or combustible structure.
- Recommended heating area and maximum burn time may vary with location in the home, chimney draft, heat loss factors, climate, fuel type, and other variables.
- Maximum heat output (dry cordwood) is based on a loading density of 15–20 lb/ft³; other performance figures are based on the standard test fuel load of 7–12 lb/ft³ at 19–25% moisture content, measured per the CSA B415.1-10 stack loss method.
- Any installation must be done according to the data and drawings detailed in the owner’s manual.
About the Manufacturer
Who Is Drolet?
Drolet is a Canadian hearth manufacturer whose history dates back to 1875, when François-Xavier Drolet opened his first workshop in Quebec. Today the brand produces wood stoves, fireplace inserts, pellet stoves, furnaces, and cookstoves recognized for durability and practical heating performance.
Performance and Certification Focus
Drolet appliances are designed to meet demanding environmental and industry standards, with current wood-burning models certified to EPA 2020 emissions requirements and tested by accredited laboratories for use in both the United States and Canada.
Manufacturing and Support
Drolet appliances are proudly made in Canada and the USA. The manufacturer supports owners through online warranty registration, replacement-parts resources, and dedicated technical support.