Full Cast Iron Convective Heat with TruHybrid™ Catalytic Combustion and Left-Side Loading
Full cast iron construction with a soapstone-lined firebox, TruHybrid™ catalytic combustion, a left-side loading door with integral ash pan, and published burn times of up to 30+ hours.
Key Features
- TruHybrid™ combustion system combining primary and secondary combustion with catalytic tertiary combustion
- EPA certified at 0.65 g/hr particulate emissions under the 2020 EPA particulate standard, tested with crib wood
- 78% HHV weighted-average efficiency, measured across four burn-rate categories using EPA Method 28R and CSA B415-10 methodology
- Published burn time of up to 30+ hours and HeatLife™ of up to 30 hours, depending on wood, draft, and operating conditions
- Built-in convective air channel up the back and across the top of the stove that helps circulate warm air through the home
- Left-side loading door accepts logs up to 24" in length; integral ash pan with shaker grate keeps the hearth tidy
- Soapstone-lined 2.45 cubic foot firebox stores heat and releases it gradually
- Heats up to a maximum of 2,400 square feet, depending on insulation, floor plan, stove placement, and fuel quality
- Cast iron rear heat shield included from the factory
- Two current finishes: Black Matte and Brown Enamel
- 6" flue collar with top or rear exit, and approval for U.S. mobile home installation when installed to the manufacturer's requirements
Product Features
TruHybrid™ Combustion Technology
The TruHybrid™ system burns the fuel, then the gases the wood releases, then routes the remaining exhaust through the catalysts for tertiary combustion. A bypass handle directs combustion products around the catalysts during startup and reloading, and through the catalysts once the catalyst thermometer shows the stove is in its active range. The Manchester uses Applied Ceramics ACI-6M2 catalytic combustors, two required per the current illustrated parts list, which require periodic inspection and eventual replacement. The catalysts become active around 500°F, and the Manchester 8362 typically operates in the 800°F to 1300°F range.
Natural Convective Heat
The Manchester is built with an air channel up the back and across the top of the stove, which helps circulate warm air through the home without a fan. An optional blower, kit 93-57600, is available for installations that call for forced air movement.
Cast Iron and Soapstone Construction
The Manchester combines full cast iron construction with a soapstone-lined firebox. The soapstone absorbs the heat of the fire and releases it gradually, supporting the stove's long published HeatLife™. HearthStone notes that soapstone requires gradual break-in fires so the natural moisture in the freshly quarried stone is driven out slowly, and that stone color may change and surface fractures may appear with use without affecting stove function.
Side Loading and Everyday Convenience
A left-side loading door accepts logs up to 24" in length, and the built-in ash pan with a shaker grate allows ash to be sifted from the firebox and carried away without shoveling through the front door. A single primary air lever below the ash lip regulates the burn rate, the bypass handle controls catalyst engagement, and a catalyst thermometer shows when the stove is in the active temperature range. HearthStone requires 18" between the loading-door side of the stove and the side wall unless the optional side door locking kit is installed, and recommends allowing space for loading through the side door.
Fire Viewing
A large glass window lets the fire be seen from a variety of locations in the room. An air-wash system helps keep the ceramic glass clear when logs are kept away from the glass and the stove is run at adequate temperatures.
Heating Performance
HearthStone publishes a heating area of up to a maximum of 2,400 square feet and a maximum heat output of 75,000 BTU per hour of cordwood. Under specific EPA test conditions, the Manchester 8362 delivered heat at rates ranging from 14,000 to 33,000 BTU (output). HearthStone states in the current owner's manual that the Manchester should not be considered the primary heat source for a home, and that factors unique to a given house can reduce the square footage the stove will heat.
Available Finishes and Configurations
The Manchester 8362 is currently orderable in two finishes. Both current configurations load through a left-side door. Pricing varies by finish.
| Finish |
Loading Configuration |
Part ID |
MSRP |
Included Equipment |
| Black Matte |
Left load |
8362-0010L |
$5,449 |
Cast iron rear heat shield included |
| Brown Enamel |
Left load |
8362-0020L |
$6,149 |
Cast iron rear heat shield included |
Pricing notice: Prices shown are current manufacturer-suggested retail prices for the stove in the selected finish. Chimney components, hearth protection, accessories, delivery, installation, and applicable taxes are additional.
Specifications
Performance
| Model |
8362 |
| Combustion system |
TruHybrid™ — primary, secondary, and catalytic tertiary combustion |
| Catalytic combustor |
Applied Ceramics ACI-6M2, two required |
| Heating area |
Up to a maximum of 2,400 sq ft |
| Maximum heat output |
75,000 BTU per hour of cordwood |
| Tested heat output range |
14,000 to 33,000 BTU (output) under specific test conditions |
| Burn time |
Up to 30+ hours |
| HeatLife™ |
Up to 30 hours |
| Typical operating range |
800°F to 1300°F catalyst temperature |
Firebox and Fuel
| Fuel type |
Natural cordwood only |
| Firebox capacity |
2.45 cu ft |
| Maximum log length |
Up to 24" (61 cm) through the side door |
| Loading |
Front door and left-side loading door |
| Ash pan |
Built in, with ash door and shaker grate |
Dimensions and Weight
| Height |
32⅛" (81.6 cm) |
| Width |
30¼" (76.8 cm) |
| Depth |
20" (50.8 cm) |
| Weight |
520 lbs (236 kg) |
| Crate dimensions |
H 49.5" x W 32.4" x L 24.5" (126 x 82.3 x 62.2 cm); add 4" (10.2 cm) for pallet |
Flue and Installation
| Flue exit location |
Top or rear |
| Flue collar and connector size |
6" (152 mm) diameter |
| Metal chimney requirement |
6" (152 mm) inside diameter, listed Type HT (2100°F) per UL 103 or ULC S629 |
| Masonry chimney requirement |
Code-approved lined chimney, 6" (152 mm) round flue or 8" x 8" (203 x 203 mm) square flue |
| Recommended minimum chimney height, top exit |
16 feet (4.9 m) off the floor, or 13 feet 5⅛" (4.1 m) from the top of the stove |
| Recommended minimum chimney height, rear exit |
19 feet (5.8 m) off the floor, or 16 feet 5⅛" (5.0 m) from the top of the stove |
| Recommended maximum chimney height |
30 feet (9 m) |
| Required draft |
0.06" to 0.1" water column; drafts above 0.1" WC require a stovepipe damper, checked at installation |
| Outside air connection |
Optional kit 93-53500, minimum 3" (76 mm) diameter duct supplied by others; adaptor 90-53308 available for 4" duct |
| Mobile home approval |
Approved in the U.S. when installed per 24 CFR Part 3280; outside air kit, floor anchoring, a spark arrester, and a listed mobile home chimney and connector kit are required; not for installation in a sleeping room |
| Fireplace installation |
Not to be installed in any factory-built fireplace |
Efficiency, Emissions, and Certification
| HHV efficiency |
78% weighted average across four burn-rate categories, measured using EPA Method 28R and CSA B415-10 methodology |
| Particulate emissions |
0.65 g/hr |
| EPA certification |
Certified to comply with the U.S. EPA 2020 particulate emissions standard, tested to EPA Method 28R, 40 CFR Part 60 where applicable, using crib wood |
| Certification file |
PFS File F19-023 |
| CO emissions by burn category |
Category 1 (low) 40.46 g/hr, Category 2 (medium low) 37.04 g/hr, Category 3 (medium high) 63.46 g/hr, Category 4 79.04 g/hr |
| Tested standards |
Conforms to UL Std. 1482-2022; certified to ULC Std. S627-2021 |
Clearances and Hearth Requirements
The values below are from the current Manchester 8362 owner's and installation manual (revision 1/9/23) and are measured from the body of the stove unless otherwise indicated. The cast iron rear heat shield is included from the factory, and the published clearances apply to the stove as shipped. Reduced clearances require the optional close clearance heat shield, kit 93-68600, which is sold separately. Double-wall connector figures shown by HearthStone are specific to Simpson Dura-Vent DVL and may vary with other brands; check the specifications from the manufacturer of your connector.
| Installation Configuration |
Measurement |
Required Clearance |
| Single-wall connector, no close clearance heat shield |
Stove body to side wall (dimension A) |
18" (46 cm) |
| Single-wall connector, no close clearance heat shield |
Stove body to rear wall (dimension B) |
16" (41 cm) |
| Single-wall connector, no close clearance heat shield |
Chimney connector to rear wall (dimension C) |
21" (54 cm) |
| Single-wall connector, no close clearance heat shield |
Chimney connector to side wall (dimension D) |
33⅝" (86 cm) |
| Single-wall connector, no close clearance heat shield |
Stove body to corner wall (dimension E) |
9" (23 cm) |
| Single-wall connector with close clearance heat shield 93-68600 |
Stove body to side wall (dimension A) |
18" (46 cm) |
| Single-wall connector with close clearance heat shield 93-68600 |
Stove body to rear wall (dimension B) |
10" (26 cm) |
| Single-wall connector with close clearance heat shield 93-68600 |
Chimney connector to rear wall (dimension C) |
15" (39 cm) |
| Single-wall connector with close clearance heat shield 93-68600 |
Chimney connector to side wall (dimension D) |
33⅝" (86 cm) |
| Single-wall connector with close clearance heat shield 93-68600 |
Stove body to corner wall (dimension E) |
9" (23 cm) |
| Double-wall connector, no close clearance heat shield |
Stove body to side wall (dimension A) |
16" (41 cm) |
| Double-wall connector, no close clearance heat shield |
Stove body to rear wall (dimension B) |
16" (41 cm) |
| Double-wall connector, no close clearance heat shield |
Chimney connector to rear wall (dimension C) |
21" (54 cm) |
| Double-wall connector, no close clearance heat shield |
Chimney connector to side wall (dimension D) |
31⅝" (81 cm) |
| Double-wall connector, no close clearance heat shield |
Stove body to corner wall (dimension E) |
9" (23 cm) |
| Double-wall connector with close clearance heat shield 93-68600 |
Stove body to side wall (dimension A) |
16" (41 cm) |
| Double-wall connector with close clearance heat shield 93-68600 |
Stove body to rear wall (dimension B) |
6" (16 cm) |
| Double-wall connector with close clearance heat shield 93-68600 |
Chimney connector to rear wall (dimension C) |
11" (28 cm) |
| Double-wall connector with close clearance heat shield 93-68600 |
Chimney connector to side wall (dimension D) |
31⅝" (81 cm) |
| Double-wall connector with close clearance heat shield 93-68600 |
Stove body to corner wall (dimension E) |
9" (23 cm) |
Side loading door: The side of the stove with the loading door must be 18" from the side wall unless the side door locking kit, 93-70607, is installed. HearthStone advises considering space for loading the stove through the side door.
Chimney connector clearances
| Connector Type and Configuration |
Vertical Pipe Length Before Elbow |
Required Clearance |
| Single-wall pipe with close clearance heat shield 93-68600 |
18" or more |
10" |
| Single-wall pipe without heat shield |
18" or more |
16" (41 cm) |
| Single-wall pipe with close clearance heat shield 93-68600 |
Less than 18" |
14" |
| Single-wall pipe without heat shield |
Less than 18" |
16" |
| Single-wall pipe, direct rear exit |
Direct rear exit |
14" without heat shield; heat shield configuration listed as N/A |
| Double-wall pipe with close clearance heat shield 93-68600 |
18" or more |
6" |
| Double-wall pipe without heat shield |
18" or more |
16" (41 cm) |
| Double-wall pipe with close clearance heat shield 93-68600 |
Less than 18" |
10" (26 cm) |
| Double-wall pipe without heat shield |
Less than 18" |
16" (41 cm) |
| Double-wall pipe, direct rear exit |
Direct rear exit |
6" without heat shield; heat shield configuration listed as N/A |
Connector clearance to ceiling
-
Single-wall connector to an unprotected ceiling: 18" minimum
-
Single-wall connector to a protected ceiling: 9" minimum
-
Double-wall connector to the ceiling: follow the connector manufacturer's specifications
The close clearance heat shield referenced in the connector tables is kit 93-68600.
Alcove installation
| Installation Configuration |
Measurement |
Required Dimension |
| Alcove, unprotected surfaces |
Minimum alcove width |
62¼" (159 cm) |
| Alcove, unprotected surfaces |
Maximum alcove depth |
52" (132 cm) |
| Alcove, unprotected surfaces |
Minimum alcove ceiling height from floor, single-wall connector |
68" (173 cm) |
| Alcove, unprotected surfaces |
Minimum alcove ceiling height from floor, double-wall connector |
61½" (163 cm) |
| Alcove, protected surfaces |
All alcove dimensions |
See NFPA 211 |
Trim and mantel clearances
| Measurement |
Required Clearance |
| Side trim clearance |
12" |
| Top trim clearance above the stove |
21" |
| Mantel clearance above the stove |
24" |
| Trim thickness shown in the manual |
1¼" |
The current manual states that the same clearances apply with the stove installed in a fireplace.
Hearth and floor protection
Combustible flooring must be protected with a covering of noncombustible material. The Manchester 8362 does not require an insulated hearth pad and there is no R-value requirement; the requirement is ember protection.
| Floor Protection Measurement |
Requirement |
Applies To |
| Minimum overall floor protection |
48" x 36¾" |
United States |
| Minimum overall floor protection |
56" x 44" |
Canada |
| Rear extension from the stove body |
2" (6 cm) |
United States and Canada |
| Extension from the loading-door opening |
16" (41 cm) |
United States |
| Extension from the loading-door opening |
18" (46 cm) |
Canada |
| Edge of the fuel-door opening to the edge of the hearth |
8" (21 cm) |
United States |
| Stove body to the side edge of the hearth |
8" (21 cm) |
Canada |
HearthStone notes that luxury vinyl plank and luxury vinyl tile flooring warrants extra consideration, as some products begin to warp at 110° Fahrenheit, and that additional shielding may be necessary depending on the flooring used. Clearances to combustible surfaces may be reduced using an NFPA 211 approved wall protection system with the additional approval of the regulatory authority having jurisdiction.
Installation notice: Clearances and hearth requirements vary by connector type, shielding, and installation configuration. Refer to the current Manchester 8362 installation manual and applicable local requirements before installation.
Included Equipment
- Manchester Model 8362 woodstove with catalytic combustors installed
- Cast iron rear heat shield, included per the current dealer listing
- Owner's manual with installation and operating instructions
- Bag of handles and hardware
Compatible Accessories
| Accessory |
Part ID |
MSRP |
Compatibility or Requirement Note |
| Outside Air Starter |
93-53500 |
$129 |
For Manchester. Required for mobile home installations; connects to a minimum 3" duct supplied by others. |
| Blower |
93-57600 |
$699 |
For Manchester. Optional convection blower. |
| Extra Close Clearance (Exit) Heat Shield |
93-68600 |
$109 |
For Manchester. Required for the reduced clearances shown in the clearance tables. Separate from the included cast iron rear heat shield. |
| Side Door Lock Kit |
93-70607 |
$99 |
For Manchester. Permits the loading-door side of the stove to be closer than 18" to the side wall. |
| 3" to 4" Outside Air Increaser |
90-53308 |
$49 |
For use when adapting the Manchester's 3" outside-air connection to 4" duct. |
All accessories listed above are optional and sold separately unless expressly stated otherwise.
Warranty
HearthStone warrants the appliance to the original retail purchaser only, when purchased by that purchaser and installed by an authorized HearthStone dealer or their designated representative, against defects in material or workmanship. Coverage begins on the date of the original invoice and is not transferable to subsequent owners.
Warranty periods differ by component. HearthStone defines the term "Limited Lifetime" as 10 years from the beginning of warranty coverage, and applies it to the stone, to cast iron not listed elsewhere, and to the clean-burning air supply system. Door handles and latches and steel components and the firebox carry a 5-year period. Appliance electrical components carry a 2-year period, as do refractory and vermiculite panels and baffles. Enamel finish against peeling or fading, glass, the ash grate, accessories, and all components not listed elsewhere carry a 1-year period. The catalytic combustors are covered directly by the combustor manufacturer, Applied Ceramics, under a separate limited warranty that provides free replacement within two years of purchase and prorated replacement pricing thereafter.
HearthStone pays for warranty labor performed by an authorized dealer during the first year after the purchase date only when the appliance was installed by an authorized dealer or their designated representative; otherwise, and thereafter, labor is the purchaser's responsibility. Exclusions include over-firing, improper installation or operation, service by anyone other than an authorized dealer, use of unapproved fuels or components, water and corrosion damage, and normal wear parts such as paint, gaskets, baffles, refractory materials, ash grates, and glass. Surface and hairline cracks and scratches in the stone that do not affect operation or safety are excluded, and HearthStone's obligation does not extend to the appliance's ability to heat a desired space. Warranty registration is not required as a condition of coverage. Refer to the complete warranty in the current Manchester 8362 owner's manual for the full terms, conditions, and limitations.
About HearthStone
HearthStone Quality Home Heating Products builds wood- and gas-burning hearth appliances in Morrisville, Vermont, and has been building industry-leading products since 1978. Its stoves are handcrafted by Vermont craftsmen from materials including heating-grade soapstone, cast iron produced at the company's own foundry in Spain, precision-made steel, and engineered ceramics, and every HearthStone soapstone stove is signed by the stove builder. The company's TruHybrid™ system, used across its current wood stove line, adds catalytic tertiary combustion to primary and secondary combustion.