cozyglowstoves Skip to content
Free Delivery on Most Orders Over $250 & Curbside Delivery in 7-10 Days (Online Only)
Free Delivery on Most Orders Over $250 & Curbside Delivery in 7-10 Days (Online Only)

Drolet Heat Commander II Wood Burning Furnace | DF02003

by Drolet
SKU DF02003
Recertified for 2025!
Original price $4,349.00 - Original price $4,349.00
Original price
$4,349.00
$4,349.00 - $4,349.00
Current price $4,349.00

Questions?

Call 1-888-323-2699, or start a chat with us today. We are available Mon.-Fri. 9 am - 5 pm EST.

Drolet Heat Commander II Wood-Burning Furnace (DF02003)

An EPA 2020 Certified Central Warm-Air Wood Furnace with Dual Fire Two-Stage Electronic Combustion Control

The Drolet Heat Commander II is a central warm-air wood furnace for 1,000–2,500 ft², with a 3.6 ft³ firebox, 21" logs, up to 10 hours of burn time, and thermostat-driven combustion control.

Key Features

  • Central warm-air wood furnace designed to distribute heat through a properly engineered duct system
  • 1,000–2,500 ft² heating area with a 3.6 ft³ firebox and up to 10 hours of burn time
  • Maximum input capacity of 310,000 BTU on dry cordwood, with a separately published nominal heat output of 75,000 BTU at a 15 lb/ft³ fuel-loading density
  • Overall heat output rate of 21,742–62,107 BTU/h and delivered heat output rate of 19,851–64,073 BTU/h
  • Average overall efficiency of 78% (HHV) and average delivered efficiency of 77% (HHV)
  • EPA 2020 approved at 0.09 lb/mmBTU (0.039 g/MJ) average particulate emissions
  • Dual Fire two-stage electronic combustion control synchronized with a fixed wall-mounted 24 V thermostat
  • Included direct-drive blower: 1/3 hp, one speed, 875 CFM at the current manual’s published test condition
  • 21" maximum log length with loading over width and depth
  • Stainless steel secondary-air system, refractory-brick firebox lining, and C-Cast or equivalent baffle
  • Glass airwash system for a cleaner view of the flames
  • Proudly made in Canada

Central-Heating System Overview

The Heat Commander II is a central warm-air wood furnace, not a freestanding room stove, fireplace insert, or zero-clearance fireplace. It heats by supplying warm air to a hot-air plenum and duct system engineered for the building, with a separate cold-air return. Overall heat output includes radiated and delivered heat, while delivered output refers to heat provided remotely through the duct system. The 310,000 BTU figure is the maximum input capacity on dry cordwood, not delivered heat output. Installation must follow the certification label and the current installation and operating manual.

Dual Fire Combustion and Thermostat Controls

The furnace uses Dual Fire two-stage electronic combustion control: automated air controls respond to thermostat demand, the furnace modulates from higher to lower combustion based on thermostatic demand, the combustion-state indicator and reload light communicate the operating condition, and the plenum RTD probe controls the distribution blower. A fixed wall-mounted 24 V thermostat is required and must be installed according to the current manual. The furnace requires regular fueling, ash management, and maintenance; it is not maintenance-free or self-cleaning.

Included Equipment

Component Details
Direct-drive blower 1/3 hp, one speed, 875 CFM at the current manual’s published test condition
Fixed wall-mounted thermostat 24 V, installed per the current manual
Adjustable hot-air plenum assembly Included
Combustion-state indicator / reload light Included
Automated combustion-control system Dual Fire two-stage electronic control
Ash lip 1
Ash drawer Included
Poker Included
Scraper Included
Hot-air plenum assembly hardware Supplied according to the current manual

Optional air filters (published optional size 15" x 20" x 1") and the optional return-air adapter are not included. A chimney, connector pipe, ductwork, registers, building wiring, hearth protection, barometric draft control, additional combustion-air duct, and installation labor are not included.

Product Specifications

Appliance Performance

Specification Value
Fuel Type Dry cordwood (16" recommended)
Heating Area 1,000 - 2,500 ft²
Overall Firebox Volume 3.6 ft³
Maximum Burn Time 10 h
Maximum Input Capacity (Dry Cordwood) 310,000 BTU
Nominal Heat Output at 15 lb/ft³ Fuel Loading Density 75,000 BTU
Minimum Overall Heat Output Rate 21,742 BTU/h (6.37 kW)
Maximum Overall Heat Output Rate 62,107 BTU/h (18.2 kW)
Minimum Delivered Heat Output Rate 19,851 BTU/h (5.82 kW)
Maximum Delivered Heat Output Rate 64,073 BTU/h (18.8 kW)
Optimum Efficiency 79% (LHV)
Optimum Heat Transfer Efficiency 81%
Average Particulate Emission Rate 0.09 lb/mmBTU (0.039 g/MJ)
Average CO 1.3 g/min
Average Electrical Power Consumption 330 W
Average Overall Efficiency 78% (HHV)
Average Delivered Efficiency 77% (HHV)

General Features and Blower

Specification Value
Size Medium
High-Efficiency Certified Appliance Yes, EPA 2020 approved
Certified According to Applicable Standards By an accredited laboratory (CAN/USA)
Premium Quality Blower (CFM) Included
Blower (hp | speed | CFM) 1/3 | 1 | 875 (per the current model manual)
Stainless-Steel Secondary-Air System Yes

Chimney Connection

Specification Value
Flue Outlet Diameter 6"
Recommended Chimney Diameter 6"
Type of Chimney CAN/ULC S629, UL 103 HT (2100 °F)
Evacuation Direction Horizontal
Distance - Center of the Flue Outlet to Floor 37 1/8"
Distance - Center of the Flue Outlet to Side of Unit 13 7/8"

Door, Glass, and Firebox

Specification Value
Door Type Single, glass with cast iron frame
Door Opening Size (Width) 13 3/4"
Door Opening Size (Height) 10"
Glass Type Ceramic glass
Glass Surface - W x H 12 3/8" x 10 1/8"
Baffle Type C-Cast or equivalent
Firebox Size (Width) 18 3/4"
Firebox Size (Height) 16 1/8"
Firebox Size (Depth) 22 3/4" (per the official appliance drawing)
Maximum Log Length 21"
Log Positioning Loading over width and over depth
Firebox Lined with Refractory Bricks Yes
Steel Thickness - Top 1/4"
Steel Thickness - Body 3/16"

Dimensions, Filter, Certifications, and Weight

Specification Value
Overall Dimension (Width) 27 3/4"
Overall Dimension (Height) 63 1/2" min.
Overall Dimension (Depth) 51 1/2" maximum (per the official appliance drawing)
Filter - Dimensions (Width x Height x Depth) 15" x 20" x 1" (option)
Hot Air Plenum - Minimum Height of the Furnace with Plenum 63 1/2" min. for a 69" ceiling | 73 1/4" to 88" for a ceiling of 78 1/4" to 93" and more
Hot Air Plenum - Height (Minimum - Maximum) 22 3/8" x 26 7/8" (plenum horizontal dimensions per the official drawing; see Furnace and Plenum Dimensions)
Canadian Standard (Safety) CAN/CSA B366.1
USA Standard (Safety) UL 391
Canadian Standard (Emissions) CSA B415.1-10
USA Standard (Emissions) EPA
Warranty Limited lifetime
Shipping Weight 758 lb (344 kg)

Furnace, Plenum, and Connection Dimensions

Furnace and Plenum Dimensions

Component Published Dimension
Furnace Width 27 3/4"
Maximum Overall Depth 51 1/2"
Minimum Furnace Height with Plenum 63 1/2"
Plenum Horizontal Dimensions 22 3/8" x 26 7/8"
Adjustable Plenum Height 22 1/2" to 47"
Maximum Configured Furnace Height 88"

The plenum footprint, the adjustable plenum height, and the total configured furnace height are separate published dimensions; verify ceiling height and layout against the current manual before installation.

Authorized Installation Configurations

Canada and United States - Standalone

The authorized standard configuration uses the Heat Commander II as the only appliance connected to its hot-air distribution system and its air-return system.

United States Only - Parallel Add-On

The current manual permits a parallel add-on configuration in the United States only when all manual requirements are satisfied, including: the wood furnace and the existing gas, oil, or electric furnace remain parallel; each furnace has its own air-return duct system; the existing furnace’s input is equal to or greater than the wood furnace’s applicable rating; the greater applicable appliance and duct clearances govern; the wood furnace’s static pressure is adjusted to 0.20 in. W.C. (50 Pa); and the controls are properly interlocked so both appliances do not operate at maximum rate simultaneously.

Prohibited Configurations

DF02003 is not approved for installation in series with another furnace; the hot-air outlet of one furnace must never feed the return-air side of the other. The furnace is not approved for mobile-home installation, not approved for alcove installation, and not approved to share a chimney flue with another appliance. Air ducts serving a garage must remain isolated as required by the manual. Installation must follow the certification label and the current manual.

Hot-Air Distribution and Return-Air Requirements

Requirement Value
Hot-Air Plenum Outlets 6 to 10
Outlet Diameter 6"
Required Plenum Static Pressure 0.20 in. W.C. (50 Pa)
Maximum Main-Duct Run 35 ft
Maximum Combined Main-Duct Length 180 ft
Maximum Secondary-Duct Run 10 ft
Maximum Combined Secondary-Duct Length 100 ft
Maximum Secondary Outputs per Main Duct 3
Recommended Register-Air Velocity 500 - 750 ft/min

The installer is responsible for system design and performance: duct quantity, length, size, balancing, insulation, and return-air capacity depend on the building, and duct sizing and configuration must follow the complete current manual. The total cold-air return volume should be at least equal to or slightly greater than the hot-air distribution volume, and rigid ductwork is favored by the manual because it is less restrictive. The furnace is not a plug-and-play room heater, and not every duct system, chimney, electrical service, or return-air layout is compatible without evaluation. The optional return-air adapter is a room-air return accessory that may improve circulation - it is not an outside-air intake, and return air and combustion air remain separate systems. The optional air-filter system is recommended by the manual to reduce dust circulation and protect the blower; neither the adapter nor the filters are included.

Chimney, Connector, Combustion-Air, and Electrical Requirements

A 6" listed solid-fuel chimney (CAN/ULC S629 or UL 103 HT) is strongly recommended; a 7" chimney may be permitted only when proper venting is verified and authorized by a qualified installer. The furnace must not share a chimney flue with another appliance, no manual flue damper may be installed, connector joints must be secured according to the current manual, chimney and connector systems must follow their manufacturers’ instructions and applicable requirements, and draft must be measured and calibrated according to the current manual. No chimney or connector system is included.

The electrical supply is 120 V on a recommended dedicated 15 A circuit, with a minimum wire temperature rating of 167°F (75°C). The thermostat is a fixed wall-mounted 24 V unit wired with 18 AWG two-conductor wire. The furnace arrives factory assembled electrically and normally connects through its power cord; installation and verification must be completed by a qualified person, electrical work must comply with applicable codes, and the plenum RTD probe must be positioned and connected according to the current manual.

Clearances with Single-Wall Connector

The information on the certification label affixed to the appliance always overrides information published in any other media. The current July 17, 2026 manual and its diagrams govern; ducts require a 1" clearance to combustible materials per the current manual.

Manual Reference Canada USA
A — From the Back of the Blower Box 14 1/4" 14 1/4"
B — See Current Manual Diagram 18" 18"
C — See Current Manual Diagram 5" 5"
D — See Current Manual Diagram 1" 1"
E — See Current Manual Diagram 69" minimum 69" minimum
F — See Current Manual Diagram 12" 12"
G — See Current Manual Diagram 5" 5"
H — See Current Manual Diagram 24" minimum 24" minimum
I — See Current Manual Diagram 11" 11"

Clearances with Double-Wall Connector

Manual Reference Canada USA
A — From the Back of the Blower Box 6 3/4" 6 3/4"
B — See Current Manual Diagram 11 1/2" recommended; otherwise use the connector manufacturer’s clearance 11 1/2" recommended; otherwise use the connector manufacturer’s clearance
C — See Current Manual Diagram 5" 5"
D — See Current Manual Diagram 1" 1"
E — See Current Manual Diagram 69" minimum 69" minimum
F — See Current Manual Diagram 12" 12"
G — See Current Manual Diagram 5" 5"
H — See Current Manual Diagram 24" minimum 24" minimum
I — See Current Manual Diagram 11" 11"

Cold-Air Return Clearance

Requirement Canada USA
Cold-Air Return Ductwork to Combustibles 0" 0"

Floor Protection

Manual Reference Canada USA
A — See Current Manual Diagram 18" from the door opening 16" from the door opening
B — See Current Manual Diagram N/A 8" from the door opening
C — See Current Manual Diagram 8" N/A
D — See Current Manual Diagram 8", subject to Note 1 N/A
E — See Current Manual Diagram N/A 2", subject to Note 2
F — See Current Manual Diagram 74" 64"
G — See Current Manual Diagram 43 3/4" 30 1/4"

Floor protection must be steel with a minimum thickness of 0.015" or sealed ceramic tile; no protector is required over an approved noncombustible floor. Note 1: rear protection is limited to the furnace’s required rear clearance when that clearance is smaller. Note 2: the protection applies beneath the horizontal connector and extends at least 2" beyond each side. Follow the current manual diagram, material requirements, certification label, and applicable local requirements.

About the Manufacturer

Who Is Drolet?

Drolet is a Canadian hearth and central-heating brand with roots dating back to 1875, manufactured by Stove Builder International (SBI) in Québec, Canada. Its wood furnaces are developed for North American homes and tested to the applicable CAN/USA standards.

Certification Focus

Drolet central-heating appliances are tested by accredited laboratories, and the Heat Commander II is EPA 2020 approved with published emission, efficiency, and output data.

Support

The manufacturer supports owners through warranty registration, replacement-parts resources, and technical-support services.

Product Downloads

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare